Finite Element Analysis of Materials and Processing of Composite Flywheel Rotor

2014 ◽  
Vol 529 ◽  
pp. 92-96 ◽  
Author(s):  
Song Yi Guo ◽  
Chong Li ◽  
Wen Yi Li

Flywheel rotor is the very important component in the flywheel energy storage system (FESS). The key factors of rotor, such as rotor materials, geometry and fabrication process, have directly influence on the performance of FESS. At present, press-assembling the rotor with shrink-fit is used usually to increase strength of composite flywheel rotors filament wound in the radial direction. This paper is concerned that the Von Mises equivalent stress distribution of the metal hub and the radial stress distribution of the composite rim at the speed of 20000rpm by the 3D finite element method. The materials and corresponding minimum value of interference fit of the flywheel rotor are determined based on the analysis results.

2013 ◽  
Vol 312 ◽  
pp. 3-10
Author(s):  
Guang Xi Li ◽  
Yin Shan Zhang ◽  
Lin He ◽  
Li Yang

In this paper, a dynamics model of flywheel rotor - support system is build. Obtained the dynamic characteristics of the flywheel rotor by finite element method .The results indicate that the rotor system is stability and security. This provides the basis for the subsequent optimization of flywheel rotor.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


Author(s):  
MR Karamooz-Ravari ◽  
R Dehghani

Nowadays, NiTi rotary endodontic files are of great importance due to their flexibility which enables the device to cover all the portions of curved canal of tooth. Although this class of files are flexible, intracanal separation might happen during canal preparation due to bending or torsional loadings of the file. Since fabrication and characterization of such devices is challenging, time-consuming, and expensive, it is preferable to predict this failure before fabrication using numerical models. It is demonstrated that NiTi shape memory alloy shows asymmetric material response in tension and compression which can significantly affect the lifetime of the files fabricated from. In this article, the effects of this material asymmetry on the bending response of rotary files are assessed using finite element analysis. To do so, a constitutive model which takes material asymmetry into account is used in combination with the finite element model of a RaCe file. The results show that the material asymmetry can significantly affect the maximum von Mises equivalent stress as well as the force–displacement response of the tip of this file.


Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1708 ◽  
Author(s):  
Maciej Zarow ◽  
Mirco Vadini ◽  
Agnieszka Chojnacka-Brozek ◽  
Katarzyna Szczeklik ◽  
Grzegorz Milewski ◽  
...  

By means of a finite element method (FEM), the present study evaluated the effect of fiber post (FP) placement on the stress distribution occurring in endodontically treated upper first premolars (UFPs) with mesial–occlusal–distal (MOD) nanohybrid composite restorations under subcritical static load. FEM models were created to simulate four different clinical situations involving endodontically treated UFPs with MOD cavities restored with one of the following: composite resin; composite and one FP in the palatal root; composite and one FP in the buccal root; or composite and two FPs. As control, the model of an intact UFP was included. A simulated load of 150 N was applied. Stress distribution was observed on each model surface, on the mid buccal–palatal plane, and on two horizontal planes (at cervical and root-furcation levels); the maximum Von Mises stress values were calculated. All analyses were replicated three times, using the mechanical parameters from three different nanohybrid resin composite restorative materials. In the presence of FPs, the maximum stress values recorded on dentin (in cervical and root-furcation areas) appeared slightly reduced, compared to the endodontically treated tooth restored with no post; in the same areas, the overall Von Mises maps revealed more favorable stress distributions. FPs in maxillary premolars with MOD cavities can lead to a positive redistribution of potentially dangerous stress concentrations away from the cervical and the root-furcation dentin.


Paleobiology ◽  
2019 ◽  
Vol 45 (1) ◽  
pp. 182-200 ◽  
Author(s):  
François Clarac ◽  
Florent Goussard ◽  
Vivian de Buffrénil ◽  
Vittorio Sansalone

AbstractThis paper aims at assessing the influence of the bone ornamentation and, specifically, the associated loss of bone mass on the mechanical response of the crocodylomorph osteoderms. To this end, we have performed three-dimensional (3D) modeling and a finite element analysis on a sample that includes both extant dry bones and well-preserved fossils tracing back to the Late Triassic. We simulated an external attack under various angles on the apical surface of each osteoderm and further repeated the simulation on an equivalent set of smoothed 3D-modeled osteoderms. The comparative results indicated that the presence of an apical sculpture has no significant influence on the von Mises stress distribution in the osteoderm volume, although it produces a slight increase in its numerical score. Moreover, performing parametric analyses, we showed that the Young's modulus of the osteoderm, which may vary depending on the bone porosity, the collagen fiber orientation, or the calcification density, has no impact on the von Mises stress distribution inside the osteoderm volume. As the crocodylomorph bone ornamentation is continuously remodeled by pit resorption and secondary bone deposition, we assume that the apical sculpture may be the outcome of a trade-off between the bone mechanical resistance and the involvement in physiological functions. These physiological functions are indeed based on the setup of a bone superficial vessel network and/or the recurrent release of mineral elements into the plasma: heat transfers during basking and respiratory acidosis buffering during prolonged apnea in neosuchians and teleosaurids; compensatory homeostasis in response to general calcium deficiencies. On a general morphological basis, the osteoderm geometric variability within our sample leads us to assess that the global osteoderm geometry (whether square or rectangular) does not influence the von Mises stress, whereas the presence of a dorsal keel would somewhat reduce the stress along the vertical axis.


2013 ◽  
Vol 07 (04) ◽  
pp. 484-491 ◽  
Author(s):  
Wagner Moreira ◽  
Caio Hermann ◽  
Jucélio Tomás Pereira ◽  
Jean Anacleto Balbinoti ◽  
Rodrigo Tiossi

ABSTRACT Objective: The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Materials and Methods: Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). Results: The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Conclusions: Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.


2012 ◽  
Vol 457-458 ◽  
pp. 567-571
Author(s):  
Liliana Sandu ◽  
Florin Topală ◽  
Sorin Porojan

A complete cast crown allows the operator to modify axial tooth contour. The margin should be smooth and distinct and its width has to allow adequate bulk of metal at the margin. The objective of this study was to evaluate, by finite element analysis, the influence of different degree of taper and marginal designs for cast crown preparations, on the stress distribution in teeth and crowns. As experimental model an upper first molar was used. The geometry of the intact tooth were obtained by 3D scanning. The tooth preparations and the complete cast crowns were designed. Models were exported in a finite element analysis software for structural simulations. Von Mises equivalent stresses were calculated and their distribution was plotted graphically. Numerical simulations provide a biomechanical explanation for stress distribution in prepared teeth and overlying crowns.


2011 ◽  
Vol 230-232 ◽  
pp. 1029-1033
Author(s):  
Xiao Qin Zhou ◽  
Shao Xin Zhao ◽  
Zhi Wei Zhu ◽  
Jie Qiong Lin ◽  
Dan Luo

In order to reveal the mechanistic characteristics during the elliptical vibration cutting (EVC), A simplified 2-D finite element model is developed. The characteristics of the cutting forces during the EVC process are investigated by comparison with the conventional cutting. The results indicate that the lower averaging values of cutting forces can be obtained and an obvious inverse phenomenon of the thrust force is also observed during the EVC process, which may be beneficial to the chip formation. A detailed analysis of the equivalent stress distribution during the EVC process is carried out. A transient stress distribution is observed during the EVC process, the highly localized Von Mises stress in the tool-chip contact region throughout one EVC cycle may help to form a more continuous chip and lead to the ductile regime removal of brittle materials.


2014 ◽  
Vol 680 ◽  
pp. 249-253
Author(s):  
Zhang Qi Wang ◽  
Jun Li ◽  
Wen Gang Yang ◽  
Yong Feng Cheng

Strain clamp is an important connection device in guy tower. If the quality of the compression splicing position is unsatisfied, strain clamp tends to be damaged which may lead to the final collapse of a guy tower as well as huge economic lost. In this paper, stress distribution on the compressible tube and guy cable is analyzed by FEM, and a large equivalent stress of guy cable is applied to the compression splicing position. During this process, a finite element model of strain clamp is established for guy cables at compression splicing position, problems of elastic-plastic and contracting are studied and the whole compressing process of compressible position is simulated. The guy cable cracks easily at the position of compressible tube’s port, the inner part of the compressible tube has a larger equivalent stress than outside.


Sign in / Sign up

Export Citation Format

Share Document