Air Compressor Piston Finite Element Analysis Based on ANSYS

2015 ◽  
Vol 713-715 ◽  
pp. 15-17
Author(s):  
Xin Xiang Zhou ◽  
Tian Shu Cong ◽  
Xing Long Lei ◽  
Feng Zhen Yang

The finite element analysis was carried out on the piston of WWD - 0.8/10 type air compressor under the action of mechanical load stress and deformation.Using three-dimensional modeling software Solidworks to establish a simplified geometric model of piston in air compressor ,Transform the model built in the three dimensional finite element analysis software into the finite element model for analysis,Determine the method of the piston by the mechanical load and boundary conditions,Completed the stress analysis and deformation analysis of the piston under the mechanical load ,The results of analysis of the piston design optimization has important reference value.

2013 ◽  
Vol 710 ◽  
pp. 243-246
Author(s):  
Xian Hong Yang

The use of Pro/E and their respective advantages ANSYS software product design and engineering analysis to solve the case, first of all in the Pro/E, the completion of three-dimensional helical gear design, and then in the Pro/MECHANICA completed finite element model of helical gear, and then into ANSYS for finite element analysis of bevel gear calculation and simulation, finite element analysis of the final results of optimization design model is presented recommendations for improvement. The product design and engineering analysis method has some reference value in engineering design.


2007 ◽  
Vol 35 (3) ◽  
pp. 226-238 ◽  
Author(s):  
K. M. Jeong ◽  
K. W. Kim ◽  
H. G. Beom ◽  
J. U. Park

Abstract The effects of variations in stiffness and geometry on the nonuniformity of tires are investigated by using the finite element analysis. In order to evaluate tire uniformity, a three-dimensional finite element model of the tire with imperfections is developed. This paper considers how imperfections, such as variations in stiffness or geometry and run-out, contribute to detrimental effects on tire nonuniformity. It is found that the radial force variation of a tire with imperfections depends strongly on the geometrical variations of the tire.


Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1152
Author(s):  
Rafał Nowak ◽  
Anna Olejnik ◽  
Hanna Gerber ◽  
Roman Frątczak ◽  
Ewa Zawiślak

The aim of this study was to compare the reduced stresses according to Huber’s hypothesis and the displacement pattern in the region of the facial skeleton using a tooth- or bone-borne appliance in surgically assisted rapid maxillary expansion (SARME). In the current literature, the lack of updated reports about biomechanical effects in bone-borne appliances used in SARME is noticeable. Finite element analysis (FEA) was used for this study. Six facial skeleton models were created, five with various variants of osteotomy and one without osteotomy. Two different appliances for maxillary expansion were used for each model. The three-dimensional (3D) model of the facial skeleton was created on the basis of spiral computed tomography (CT) scans of a 32-year-old patient with maxillary constriction. The finite element model was built using ANSYS 15.0 software, in which the computations were carried out. Stress distributions and displacement values along the 3D axes were found for each osteotomy variant with the expansion of the tooth- and the bone-borne devices at a level of 0.5 mm. The investigation showed that in the case of a full osteotomy of the maxilla, as described by Bell and Epker in 1976, the method of fixing the appliance for maxillary expansion had no impact on the distribution of the reduced stresses according to Huber’s hypothesis in the facial skeleton. In the case of the bone-borne appliance, the load on the teeth, which may lead to periodontal and orthodontic complications, was eliminated. In the case of a full osteotomy of the maxilla, displacements in the buccolingual direction for all the variables of the bone-borne appliance were slightly bigger than for the tooth-borne appliance.


2013 ◽  
Vol 442 ◽  
pp. 229-232 ◽  
Author(s):  
Li Mei Wu ◽  
Fei Yang

According to the cutting theory of involute tooth profile, established an exact three-dimensional parametric model by UG. Used ABAQUS to crate finite element model for gear meshing. After simulated the meshing process, discussed the periodicity of the tooth surface contact stress. Based on the result of finite element analysis, made a comparison of the maximum contact stress between finite element solution and Hertz theoretical solution, analyzed the contact stress distribution on tooth width, and researched the effect of friction factor on contact stress. All that provided some theoretical basis for gear contact strength design.


2013 ◽  
Vol 273 ◽  
pp. 588-592
Author(s):  
Zhi Yuan Yan ◽  
Dong Mei Wu ◽  
Li Tao Zhang ◽  
Jun Zhao

In order to obtain high-quality analytical results of the finite element model, it is essential to construct a three dimensional geometric model. The paper reconstructed an accurate three dimensional geometric model of cervical spine segments (C4-C7). The process of reconstruction included three-dimensional reconstruction, smooth processing, contour generation, grid generation and fitting surface. Moreover, the result of reconstruction was evaluated ultimately. The model was validated to be smooth and reasonable, and could meet the requirements of finite element analysis. The method is not merely applied to reconstruct the geometric model of the cervical spine. It is a way to construct the model of the skeletal system of the human body.


2018 ◽  
Vol 10 (6) ◽  
pp. 168781401877525 ◽  
Author(s):  
Shangjun Ma ◽  
Chenhui Zhang ◽  
Tao Zhang ◽  
Geng Liu ◽  
Shumin Liu

In this article, 3D or three-dimensional finite element analysis is used to simulate and evaluate the load distribution characteristics of a planetary roller screw mechanism under thermo-mechanical coupling. The finite element model takes into account the installation modes of the planetary roller screw mechanism, which is verified by comparison with theoretical models for a certain load magnitude in four installation modes. In addition, the effects of the installation mode, load magnitude, and temperature condition on the load distribution are also systematically analyzed. The numerical results reveal a phenomenon of threads separating from the meshing, which indicates that the influence of thermo-mechanical coupling on the load distribution cannot be ignored. Furthermore, the influence of the installation mode on the screw–roller interface is larger than that on the nut–roller interface. Compared with the screw–roller interface, the temperature difference is one of the main conditions affecting the load distribution of the planetary roller screw mechanism and has a significant effect on the nut–roller interface. In addition, the influences of the screw rotational speed and the load magnitude on the load distribution on the screw–roller interface are larger than those on the nut–roller interface for the four installation modes.


2014 ◽  
Vol 518 ◽  
pp. 190-195
Author(s):  
Ying Jie Duan ◽  
Ling Chen ◽  
Tao Xiong ◽  
Xing Hua Niu

To compare the strain and stress distribution on jaw bone around the implant with different crown-root and different teeth high in teeth repairing, three-dimensional geometric model of the implant was created and analyzed through UG and finite element analysis software. Model came to workbench software after it was drawn and assembly by 3D mapping software of UG. Given material properties of the model, meshing, boundary conditions and forces applied for analysis. It was Obtained that the size and distribution of stress and strain about jaw bone and implant under different conditions. The influence of jaw bone and implant in different conditions was discussed. The main results of the study are as follows: different implant and crown-root, maximum stress with the crown-root increases, but the maximum stress is placid. Factor in the high thread where the maximum stress with high thread show an inverted "U" shape, the maximum strain with high thread becomes flat.


2010 ◽  
Vol 118-120 ◽  
pp. 147-150
Author(s):  
Da Zhao Yu ◽  
Yue Liang Chen ◽  
Yong Gao ◽  
Wen Lin Liu ◽  
Zhong Hu Jia

Three-dimensional finite element model of a cracked bolted joint has been developed in the non-linear finite element code MSC.Marc and attempts were made to validate it by comparing results with those of experiments and other finite element. Issues in modeling the contact between the joint parts, which affect the accuracy and efficiency of the model, were presented. Experimental measurements of load transfer were compared with results from finite element analysis. The results show that three-dimensional finite element model of cracked bolted joint can produce results in close agreement with experiment. Three-dimensional effects such as bolt titling, seconding and through-thickness variations in stress and strain are well represented by such models. Three-dimensional finite element analysis was also used to study the effects of hole mod and crack on the load transfer behaviour of single lap bolted joints. The results show that hole mode has big effect on load transfer of cracked bolted joint. In the whole progress of crack growth, the load transfer through bolt 1 decrease, and almost all of the load duduction of bolt 1 transfer into blot 2 rather than into bolt 3.


2015 ◽  
Vol 6;18 (6;11) ◽  
pp. E1101-E1110
Author(s):  
Ah-Reum Cho

Background: Vertebroplasty is an effective treatment for osteoporotic vertebral fractures, which are one of the most common fractures associated with osteoporosis. However, clinical observation has shown that the risk of adjacent vertebral body fractures may increase after vertebroplasty. The mechanism underlying adjacent vertebral body fracture after vertebroplasty is not clear; excessive stiffness resulting from polymethyl methacrylate has been suspected as an important mechanism. Objectives: The aim of our study was to compare the effects of bone cement stiffness on adjacent vertebrae after osteoporotic vertebroplasty under load-controlled versus displacementcontrolled conditions. Study Design: An experimental computer study using a finite element analysis. Setting: Medical research institute, university hospital, Korea. Methods: A three-dimensional digital anatomic model of L1/2 bone structure was reconstructed from human computed tomographic images. The reconstructed three-dimensional geometry was processed for finite element analysis such as meshing elements and applying material properties. Two boundary conditions, load-controlled and displacement-controlled methods, were applied to each of 5 deformation modes: compression, flexion, extension, lateral bending, and torsion. Results: The adjacent L1 vertebra, irrespective of augmentation, revealed nearly similar maximum von Mises stresses under the load-controlled condition. However, for the displacementcontrolled condition, the maximum von Mises stresses in the cortical bone and inferior endplate of the adjacent L1 vertebra increased significantly after cement augmentation. This increase was more significant than that with stiffer bone cement under all modes, except the torsion mode. Limitations: The finite element model was simplified, excluding muscular forces and incorporating a large volume of bone cement, to more clearly demonstrate effects of bone cement stiffness on adjacent vertebrae after vertebroplasty. Conclusion: Excessive stiffness of augmented bone cement increases the risk of adjacent vertebral fractures after vertebroplasty in an osteoporotic finite element model. This result was most prominently observed using the displacement-controlled method. Key words: Bone cements, displacement-controlled method, finite element analysis, loadcontrolled method, osteoporosis, osteoporotic fracture, polymethyl methacrylate, vertebroplasty


2020 ◽  
Author(s):  
Zhun Xu ◽  
Yikai Li ◽  
Shaoqun Zhang ◽  
Liqing Liao ◽  
Kai Wu ◽  
...  

Abstract Background: Clinical studies have found that manipulations have a good clinical effect on sacroiliac joint (SIJ) pain without specific causes. However, the specific mechanisms of manipulations are still unclear. The purpose of this study was to investigate the effects of three common manipulations on the pressures and displacements of SIJ, and the strains of the surrounding ligaments. Methods: A three-dimensional finite element model of the pelvis-femur was developed. The manipulation of hip and knee flexion (MHKF), the manipulation of oblique pulling (MOP), and the manipulation of lower limb hyperextension (MLLH) were simulated. The pressures and displacements of SIJs, and the strains of the surrounding ligaments were analyzed under the three manipulations. Results: The MOP produced the greatest pressure on the left SIJ, at 6.6 MPa, while the MHKF could produce the lowest pressure on the right SIJ, at 1.5 MPa. The displacements of SIJs were all less than 1mm in the three manipulations. The three manipulations could cause different degrees of the strains of ligaments around the SIJs, and the MOP could produce the largest strain of ligaments. Conclusion: The three manipulations all produced small displacements of SIJs, while they caused different degrees of ligament strains, which might be the reason for relieving the SIJ pain. The MOP may be a more effective manual therapy. Key words: Manipulation, Sacroiliac joint, Displacement, Ligament strain, Finite element analysis.


Sign in / Sign up

Export Citation Format

Share Document