Electrical Resistivity of Cement Based Materials

2016 ◽  
Vol 833 ◽  
pp. 102-107 ◽  
Author(s):  
Sharifah Masniah Wan Masra ◽  
Norsuzailina Mohamed Sutan ◽  
A.K. Keran ◽  
N.D. Matudin

Electrical resistivity (ER) of cement based materials (CBM) is an important measurement that indirectly relates to the durability of CBM. This study investigates the correlation between ER of CBM namely concrete with water-to-cement (w/c). As one of CBM hydration parameters w/c is an important parameter that contributes to variations of ER. The results of this study showed that different w/c can be used as indication for the setting characteristics as well as the pore structure of the concrete. ER is obtained by applying current into the concrete and measuring the response voltage during concrete hydration period of 28 days. Two aspects were also being considered in this study: (i) test specimen size and (ii) spacing between the probes. Results show the direct correlation between ER and test specimen sizes and spacing between the probes.

Materials ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2220 ◽  
Author(s):  
Xiaohu Wang ◽  
Yu Peng ◽  
Jiyang Wang ◽  
Qiang Zeng

Mercury intrusion porosimetry (MIP) is questioned for possibly damaging the micro structure of cement-based materials (CBMs), but this theme still has a lack of quantitative evidence. By using X-ray computed tomography (XCT), this study reported an experimental investigation on probing the pore structure damages in paste and mortar samples after a standard MIP test. XCT scans were performed on the samples before and after mercury intrusion. Because of its very high mass attenuation coefficient, mercury can greatly enhance the contrast of XCT images, paving a path to probe the same pores with and without mercury fillings. The paste and mortar showed the different MIP pore size distributions but similar intrusion processes. A grey value inverse for the pores and material skeletons before and after MIP was found. With the features of excellent data reliability and robustness verified by a threshold analysis, the XCT results characterized the surface structure of voids, and diagnosed the pore structure damages in terms of pore volume and size of the paste and mortar samples. The findings of this study deepen the understandings in pore structure damages in CBMs by mercury intrusion, and provide methodological insights in the microstructure characterization of CBMs by XCT.


SPE Journal ◽  
2016 ◽  
Vol 21 (06) ◽  
pp. 1930-1942 ◽  
Author(s):  
Huangye Chen ◽  
Zoya Heidari

Summary Complex pore geometry and composition, as well as anisotropic behavior and heterogeneity, can affect physical properties of rocks such as electrical resistivity and dielectric permittivity. The aforementioned physical properties are used to estimate in-situ petrophysical properties of the formation such as hydrocarbon saturation. In the application of conventional methods for interpretation of electrical-resistivity (e.g., Archie's equation and the dual-water model) and dielectric-permittivity measurements [e.g., complex refractive index model (CRIM)], the impacts of complex pore structure (e.g., kerogen porosity and intergranular pores), pyrite, and conductive mature kerogen have not been taken into account. These limitations cause significant uncertainty in estimates of water saturation. In this paper, we introduce a new method that combines interpretation of dielectric-permittivity and electrical-resistivity measurements to improve assessment of hydrocarbon saturation. The combined interpretation of dielectric-permittivity and electrical-resistivity measurements enables assimilating spatial distribution of rock components (e.g., pore, kerogen, and pyrite networks) in conventional models. We start with pore-scale numerical simulations of electrical resistivity and dielectric permittivity of fluid-bearing porous media to investigate the structure of pore and matrix constituents in these measurements. The inputs to these simulators are 3D pore-scale images. We then introduce an analytical model that combines resistivity and permittivity measurements to assess water-filled porosity and hydrocarbon saturation. We apply the new method to actual digital sandstones and synthetic digital organic-rich mudrock samples. The relative errors (compared with actual values estimated from image processing) in the estimate of water-filled porosity through our new method are all within the 10% range. In the case of digital sandstone samples, CRIM provided reasonable estimates of water-filled porosity, with only four out of twenty-one estimates beyond 10% relative error, with the maximum error of 30%. However, in the case of synthetic digital organic-rich mudrocks, six out of ten estimates for water-filled porosity were beyond 10% with CRIM, with the maximum error of 40%. Therefore, the improvement was more significant in the case of organic-rich mudrocks with complex pore structure. In the case of synthetic digital organic-rich mudrock samples, our simulation results confirm that not only the pore structure but also spatial distribution and tortuosity of water, kerogen, and pyrite networks affect the measurements of dielectric permittivity and electrical resistivity. Taking into account these parameters through the joint interpretation of dielectric-permittivity and electrical-resistivity measurements significantly improves assessment of hydrocarbon saturation.


Sign in / Sign up

Export Citation Format

Share Document