Research on the Load Capacity of Separation Concrete-Filled Steel Tubes Subjected to Eccentric Compression on Separation Side

2010 ◽  
Vol 168-170 ◽  
pp. 632-636 ◽  
Author(s):  
Xia Ping Liu ◽  
Shu Tang ◽  
Chun Hui Tang ◽  
Zuo Yong Yang ◽  
Zuo Sun

This paper deals with the ultimate load capacity test on 14 short columns of separation concrete-filled steel tubes (CFST) which are subjected to the eccentric compression on separate side. The experimental parameters include the separation ratio and the eccentricity ratio. The result shows that the separation ratio and the eccentricity ratio will influence the load capacity of the components of the concrete-filled steel tubes which are subjected to the eccentric compression. The confinement of steel tubes to core concrete will be continuously weakened and the ultimate load capacity of the components will be decreased obviously with both the separation ratio and the eccentricity ratio increasing gradually.

2011 ◽  
Vol 117-119 ◽  
pp. 887-892 ◽  
Author(s):  
Xia Ping Liu ◽  
Zhuo Sun ◽  
Hai Yun Huang ◽  
Shu Tang ◽  
Chun Hui Tang

This document deals with the whole process compression model test on 12 short columns of separation concrete-filled steel tubes (CFST) which are subjected to eccentric compression on the non-separation side. The experimental parameters include the separation ratio and the eccentricity ratio. The results show that the separation ratio and the eccentricity ratio will influence CFST components’ mechanical properties which contain the relationship of load-strain amd load-deformation, that especially embodied in the nonlinear stage. When compressed on non-separation side, the confinement of steel tubes to core concrete will be continuously weakened and the ultimate load capacity of the components will be decreased obviously with both the separation ratio and the eccentricity ratio increasing gradually. But it less serious which compare with that compressed on separation side.


2018 ◽  
Vol 80 (2) ◽  
Author(s):  
Azrul Abd Mutalib ◽  
Mohamed Hamza Mussa ◽  
Khaleel Mohammad Khaleel Abusal

Recently, the concrete filled stainless steel tubes (CFSST) columns are widely applied in modern construction due to its aesthetic appearance, high corrosion resistant and less construction cost. The current study aims to evaluate the behavior of CFSST column with square hollow section (SHS) numerically under axial compressive load by using ABAQUS software. A good consistency had achieved between the numerical and experimental test results in terms of load-displacement behaviour and ultimate strength with a maximum difference equal to 2%. Intensive parametric studies had been conducted to determine the effects of stainless steel tubes and concrete properties on the ultimate load capacity of CFSST column. The results proved that the stainless steel tube thickness (t) capable to increase the strength of column by143.59% at t = 10 mm as compared with t = 2 mm, whereas a slight effect had observed for the variation of stainless steel proof stress ( ). On the other hand, the higher values of concrete strength (fc′) obviously reduced the lateral expansion of CFSST column at initial load and led to increase the ultimate load capacity by 34.18 % at fc′ = 80 MPa as compared with  fc′ = 30 MPa. Furthermore, the design strengths calculated according to the Eurocode 4 for concrete filled steel tube (CFST) column appeared a good agreement with the numerical results within an average difference value 2.49%, hence, it could consider as the most rational design method to determine the ultimate strength of CFSST column.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Wu Bin ◽  
Tan Zhuoying ◽  
Li Fan ◽  
Wang Sun

Tests on twelve circular concrete-filled steel tube stub columns with mixed red mud and three circular concrete-filled steel tube stub columns to investigate the influence of the mixed proportion of red mud on the mechanical behavior of axial compressive circular concrete-filled steel tube stub columns are reported. It is found that with the increase of red mud content, the ultimate load increases first and then decreases; on the contrary, the ultimate displacement decreases first and then increases; the specimen stress reaches the proportion limitation as the steel tube longitudinal strain is around 160 με and reaches the yield limitation as the steel tubes’ longitudinal strain is around 4400∼5000 με. The axial compressive bearing capacity empirical formulation of concrete-filled steel tubes stub columns mixed with red mud is proposed. The theoretical calculation results agree well with those experimental data.


2013 ◽  
Vol 790 ◽  
pp. 181-184
Author(s):  
Hai Lun Tong ◽  
Tian Hong Wang ◽  
Jian Qi Lu ◽  
Xin Tang Wang

The post-fire axial compressive behavior of a set of steel fiber reinforced ceramsite concrete filled steel tubular short columns (noted as SFCC-SSC) was experimentally studied. Effect of the maximum value of fire response temperatures of the specimens and some parameters on the axial compression performance of the specimens was especially discussed. The results show that the surface of the steel tubes after fire presented dark red for 700°Cof furnace temperature and orange red for 900°C, and there was no obvious descending segment in post-fire load-displacement curves of the most specimens subjected to fire load. It was concluded that the axial bearing capacity of the specimens aftersuffering the furnace temperature of 900°C is much less than that of the specimens not subjected to fire load, and the volume of steel fiber of 0.5% of has the greatest effect on post-fire bearing capacity of specimens of SFCC-SSC.


1967 ◽  
Vol 93 (3) ◽  
pp. 259-267
Author(s):  
Marek Janas ◽  
Lance A. Endersbee ◽  
M.L. Juncosa ◽  
K.V. Swaminathan ◽  
A. Rajaraman

Sign in / Sign up

Export Citation Format

Share Document