Simulating Research on a New Current Controlling Method

2011 ◽  
Vol 354-355 ◽  
pp. 1016-1021
Author(s):  
Jin Jie Peng ◽  
Xiao Ping Fan

A new current detecting algorithm is proposed in the paper, which is applied in an improved hybrid active power filter. The filter equipment can be applied in high voltage system to suppress harmonics and compensate reactive power. The topology and filtering principle of the filter equipment is given. The harmonic suppressing function is adopted to analyze the influence by the grid impedance, quality factor and losing resonance of the resonance circuit. The feasibility of the proposed system is validated in theory. A single-phase current detecting method is also proposed. The corresponding current control is formed combined the DC-link current detecting method. The simulating results prove that the system is feasibility and the current control is validity. Harmonic and reactive power are suppressed well.

2011 ◽  
Vol 201-203 ◽  
pp. 1512-1516
Author(s):  
Jing Jie Peng ◽  
Xiao Ping Fan ◽  
Gang Li

A new hybrid active power filter (NHAPF) and its corresponding controlling method are proposed in the paper, which can be applied in high voltage system. The topology structure of NHAPF is given and its compensating principle is described. The corresponding controlling method is a power direct control, which need not the lower pass filter and improve the performance of detecting precision and velocity. Simulating results show that the feasibility and validity of the compensated system. Harmonic currents and reactive power are compensated well.


Author(s):  
Karunendra Kumar Verma ◽  
V. M. Mishra ◽  
Niraj Kumar

Traditionally, the major part of the electrical power is generally consumed by the non-linear loads due to frequent application of the semiconductor devices in the form of domestic and industrial loads. This results from distortion in the actual supply voltage waveform at the source end due to the interference of the multiple harmonics generated out of semiconductor devices used at load end and excessive absorption of the reactive power. The insufficiency of these compensation techniques leads to the advent of the phase multiplication techniques as well as the most reliable and economic active power filtering scheme. A deep analysis showing tedious waveforms using the ORCAD simulation package for the various kind of loads in conjunction with the single-phase active power filter shunted to the single-phase line at the load end for the two current control techniques (i.e., hysteresis band current control, triangularization of current control) has been done. The results are analyzed and tested to lead the optimistic approach for APF (active power filters).


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


2013 ◽  
Vol 385-386 ◽  
pp. 1224-1228
Author(s):  
Yun Liang Wang ◽  
Qi Liang Guo

In this paper, the hysteresis current control (HCC) technique based on space vector modulation (SVM) for active power filter (APF) is proposed. The switching control algorithms of the HCC based SVM manage to generate compensated current according to the reference current. Harmonics extraction is calculated for the power compensation based on the instantaneous active and reactive power theorem in time domain. A closed loop control system is carried out and the APF manages to generate better compensated harmonics currents to the power grid.


Sign in / Sign up

Export Citation Format

Share Document