Energy Consumption Analysis on Office Building Ventilation

2012 ◽  
Vol 516-517 ◽  
pp. 1139-1143
Author(s):  
Ke Chun Sun ◽  
Wei Jun Zhang

Chongqing weather conditions as the representative, energy simulation software DesT-c Chongqing office building energy simulation analysis, simulated natural building under different ventilation conditions at room temperature, the energy consumption of building cooling load and air-conditioning system changes, with an emphasis on energy-saving effect of the night ventilation; The study showed that in Chongqing reasonable use of ventilation reduce building natural room temperature to a certain extent; Sensitive indicators of building air conditioning energy consumption than the heating energy consumption of ventilation was significantly; Night ventilation when the number of ventilators is less than 5 times / h, the energy saving effect is very significant.

2011 ◽  
Vol 99-100 ◽  
pp. 644-649
Author(s):  
Yan Qiu Cui ◽  
Rui Han Wei ◽  
Cai Ling Luo ◽  
Ji Kui Miao

In order to quantify energy saving effect of existing building envelope reconstruction, the paper makes the envelope reconstruction project of Jinan Lixia Office Building as a case, uses energy consumption simulation software DeST-C to make dynamic simulation analysis on several aspects such as natural room temperature, cold and hot load before and after reconstruction of experimental building in cold area. After reconstruction, accumulative hot load of building obtained by calculation decreases 33%, accumulative cold load decreases 15.67%, total load decreases 21.04% in the whole year, and the results show energy saving reconstruction effect of existing building envelope is remarkable.


2019 ◽  
Vol 29 (2) ◽  
pp. 270-285 ◽  
Author(s):  
MA Boukli Hacene ◽  
NE Chabane Sari

The global energy context of the year 2018 makes us pessimistic about the future. The geopolitical, environmental and socio-economic aspects are linked to the political tensions of countries that hold and manipulate the global energy market. These countries are haunted by the population growth, the depletion of fossil resources and the global economic crisis. Each country is trying to find reasonable solutions to deal with this crisis. Unfortunately, these solutions always have direct negative repercussions on the population and on the environment. In this paper we present a case study developed in Algeria and inspired by the current and critical socio-economic situation of the country, in particular, the application of energy-saving techniques to an existing building. The investigation was conducted by using both simulation software and real interventions. We analyse some of the major components, such as building’s orientation and exposure to daylight which have significant impact on energy consumption. We present the concept of Building Performance Simulation Analysis, using Autodesk ECOTECT Analysis and COMSOL Multiphysics software, and give full consideration to various ecological energy-saving methods. Using our models, we present a possible solution for retrofitting a building to minimize its energy consumption. The results are useful for both building energy conversation and creating a comfortable living environment in future.


2011 ◽  
Vol 225-226 ◽  
pp. 239-242 ◽  
Author(s):  
Hong Lei Ma ◽  
Jian Hui Niu

An energy saving residential building in Zhangjiakou was took as research object, which was designed and constructed according to the criterion of 65% energy saving of the third stage, utilizing simulation software Dest, which was developed by Qinghua University, energy consumption simulation and economic analysis were done to the building. The results show that compared with the former residence which was built according to the non-energy saving design, the implementation of new design standard for building energy saving can not only achieve better energy saving effect, but also its payback period is short, so the new design standard for building energy saving is worth spreading.


2013 ◽  
Vol 409-410 ◽  
pp. 606-611 ◽  
Author(s):  
Zhen Yu ◽  
Wei Lin Zhang ◽  
Ting Yong Fang

Using the energy consumption simulation software to research the HVAC in fall air conditioning mode, different building orientation and window-wall ratio of the office building energy consumption. The study found that the heating energy consumption, air-conditioning energy consumption and total energy consumption is gradually increased with the increase of the window-wall ratio under the same orientation. The result provides some reference for public buildings in setting of building orientation and window-wall ratio.


2021 ◽  
Author(s):  
Sara Damyar

Building envelope retrofits is one of the options available to reduce energy consumption of postwar MURBs in Toronto. This study evaluates the impact of building envelope retrofits that meet current standards on energy consumption of a Toronto postwar MURB; utilizing eQUEST energy simulation software. Further upgrades also take place to evaluate how the impact of building envelope retrofits on energy use can be increased and optimized for all assemblies of building envelope and airtightness. Moreover, the retrofit strategies are ranked based on cost and energy-saving effectiveness. The results of the analysis reveal that building envelope retrofit based on OBC-2012 standards can reduce the energy consumption by up to 44%. Furthermore, the optimal RSI values of all building envelope components were found to be equal or less than code requirements which outcomes significant energy savings. Lastly, the ranking of the strategies helps to identify the best option according to the priorities of a project.


2014 ◽  
Vol 953-954 ◽  
pp. 1578-1583
Author(s):  
Tian Yu Xiong ◽  
Xiu Zhang Fu ◽  
Jian Dong

Rural dwellings have a big difference in the appearance and envelope. Living form is changing a lot from detached house to the apartment in multi-story apartments. These changes affect building’s energy consumption consisting of heating and cooling. This paper focuses on the impact of the energy consumption affected by different surface volume ratios, simulation analysis showed a general argument of the difference. And for the same house type, this paper also compares the energy-saving effect of different envelop performances, Specific contents are the heat transfer coefficient and shading ways. Simulation results identified that SVR has influence on different types of houses, the energy consumption of row houses can be saved more than 30% compared with detached houses. Envelope performance also affects energy consumption and the national standard is recommended for the energy saving and the comfort.


2020 ◽  
pp. 130-140
Author(s):  
Guozeng Wu , Tao Li , Yijin Gang

On the basis of ensuring the requirements of process air parameters, the air conditioning control should reduce the energy consumption of the air conditioning system to the maximum extent. In this paper, by improving the adjusting speed and stability of the air conditioning system, and according to the process of environmental indicators allow deviation of belt, on the premise of not beyond the maximum technical index requirements by control algorithm to achieve better energy saving effect.


2021 ◽  
Author(s):  
Sara Damyar

Building envelope retrofits is one of the options available to reduce energy consumption of postwar MURBs in Toronto. This study evaluates the impact of building envelope retrofits that meet current standards on energy consumption of a Toronto postwar MURB; utilizing eQUEST energy simulation software. Further upgrades also take place to evaluate how the impact of building envelope retrofits on energy use can be increased and optimized for all assemblies of building envelope and airtightness. Moreover, the retrofit strategies are ranked based on cost and energy-saving effectiveness. The results of the analysis reveal that building envelope retrofit based on OBC-2012 standards can reduce the energy consumption by up to 44%. Furthermore, the optimal RSI values of all building envelope components were found to be equal or less than code requirements which outcomes significant energy savings. Lastly, the ranking of the strategies helps to identify the best option according to the priorities of a project.


Author(s):  
Yin Zhang ◽  
Xin Wang ◽  
Eric Hu

Night ventilation has great energy saving potentials for public buildings in summer. However, night mechanical ventilation inevitably causes more fan energy consumptions, even though it can reduce the cooling loads for the next day and save the air conditioning energy consumption correspondingly. Thus the optimization of night mechanical ventilation strategy is highly significant for building energy efficiency. In this paper, the simplified two-plate room model is used and the optimization model of the mechanical ventilation and air conditioning system is established. To minimize the total energy consumption, the optimal night ventilation strategy is determined through inverse problem method. Taking an office room in Beijing as the illustrative example, the results show that the optimal air exchange rate for night mechanical ventilation is much higher than the traditional value (ACH = 0.5 h−1) and it highly depends on the indoor-outdoor air temperature difference and cooling load demands. Moreover, the total electricity usage amount can decline from 210 kWh to 111 kWh after optimization, reduced by about 47% in the whole summer season. It also indicates that the energy saving effect of night ventilation mainly derives from the cooling storage and load shifting of building internal walls. Compared to traditional ventilation strategy, the energy saving ratio increases with increasing thermal conductivity and specific heat of building internal walls. This work can provide guidance for practical ventilation system optimization design and operation strategy determination.