3D Numerical Simulation of the Influence of AGD Beams on Gas Distribution in COREX-3000 Shaft Furnace

2013 ◽  
Vol 712-715 ◽  
pp. 1268-1273 ◽  
Author(s):  
Heng Zhou ◽  
Zhi Guo Luo ◽  
Tao Zhang ◽  
Jun Jie Sun ◽  
Li Hao Han ◽  
...  

A three-dimensional mathematical model is developed to describe the influence of AGD beams on gas distribution in COREX-3000 shaft furnace. The calculated result shows that with AGD beams installed, the pressure drop in furnace is decreased while the volume of low velocity zone at bottom of furnace is enlarged. AGD channels can lead reduction gas into shaft center, and increase the gas velocity at slots level, but it have little effect on gas distribution at upper part of the furnace. AGD beams are also good at restraining down pipe gas, and the volume fraction of down pipe gas declines from 9.89 % to 6.41 %, decreases about 35.2%. 2#COREX furnace with AGD beams is better at achieving uniform gas distribution.


1979 ◽  
Vol 69 (2) ◽  
pp. 369-378
Author(s):  
George A. McMechan

abstract Plotting of three-dimensional ray surfaces in p-Δ-z space provides a means of determining p-Δ curves for any focal depth. A region of increasing velocity with depth is represented in p-Δ-z space by a trough, and a region of decreasing velocity, by a crest. Two sets of ray trajectories, the arrivals refracted outside a low-velocity zone, and the guided waves inside the zone, can be merged into a single set along the ray that splits into two at the top of the low-velocity zone. This ray is common to both sets. This construction provides continuity of the locus of ray turning points through the low-velocity zone and thus allows definition of p-Δ curves inside as well as outside the low-velocity zone.



Author(s):  
Heng Zhou ◽  
Shuyu Wang ◽  
Binbin Du ◽  
Mingyin Kou ◽  
Zhiyong Tang ◽  
...  

AbstractIn order to develop the central gas flow in COREX shaft furnace, a new installment of center gas supply device (CGD) is designed. In this work, a coupled DEM–CFD model was employed to study the influence of CGD on gas–solid flow in COREX shaft furnace. The particle descending velocity, particle segregation behaviour, void distribution and gas distribution were investigated. The results show that the CGD affects the particles descending velocity remarkably as the burden falling down to the slot. Particle segregation can be observed under the inverse ‘V’ burden profile, and the influence of CGD on the particle segregation is unobvious on the whole, which causes the result that the voidage is slightly changed. Although the effect of CGD on solid flow is not significant, the gas flow in shaft furnace has an obvious change. Compared with the condition without CGD, in the case with CGD, the gas velocity is improved significantly, especially in the middle zone of the furnace, which further promotes the center gas distribution. Meanwhile, the pressure drop in the furnace with the installation of CGD is increased partly.



1970 ◽  
Vol 4 (1) ◽  
pp. 62-64 ◽  
Author(s):  
Don L. Anderson ◽  
Hartmut Spetzler


2012 ◽  
Vol 337-338 ◽  
pp. 25-38 ◽  
Author(s):  
Ralf T.J. Hansen ◽  
Michael G. Bostock ◽  
Nikolas I. Christensen


Author(s):  
P. Fede ◽  
O. Simonin ◽  
I. Ghouila

Three dimensional unsteady numerical simulations of dense pressurized polydisperse fluidized bed have been carried out. The geometry is a medium-scale industrial pilot for ethylene polymerization. The numerical simulation have been performed with a polydisperse collision model. The consistency of the polydisperse model predictions with the monodisperse ones is shown. The results show that the pressure distribution and the mean vertical gas velocity are not modified by polydispersion of the solid phase. In contrast, the solid particle species are not identically distributed in the fluidized bed indicating the presence of particle segregation.



2021 ◽  
Author(s):  
JD Eccles ◽  
AK Gulley ◽  
PE Malin ◽  
CM Boese ◽  
John Townend ◽  
...  

© 2015. American Geophysical Union. All Rights Reserved. Fault Zone Guided Waves (FZGWs) have been observed for the first time within New Zealand's transpressional continental plate boundary, the Alpine Fault, which is late in its typical seismic cycle. Ongoing study of these phases provides the opportunity to monitor interseismic conditions in the fault zone. Distinctive dispersive seismic codas (~7-35Hz) have been recorded on shallow borehole seismometers installed within 20m of the principal slip zone. Near the central Alpine Fault, known for low background seismicity, FZGW-generating microseismic events are located beyond the catchment-scale partitioning of the fault indicating lateral connectivity of the low-velocity zone immediately below the near-surface segmentation. Initial modeling of the low-velocity zone indicates a waveguide width of 60-200m with a 10-40% reduction in S wave velocity, similar to that inferred for the fault core of other mature plate boundary faults such as the San Andreas and North Anatolian Faults.



1978 ◽  
Vol 41 (4) ◽  
pp. 670-683 ◽  
Author(s):  
P. J. Wyllie


Sign in / Sign up

Export Citation Format

Share Document