An Improved Islanding Detection Method for Photovoltaic Grid-Connected System

2013 ◽  
Vol 748 ◽  
pp. 453-456
Author(s):  
Chen Xin Li ◽  
Qi Ping Yuan

Islanding detection is a very essential function for a photovoltaic grid-connected system. Islanding phenomenons not only damage to equipment, but also endanger to the safety of the maintenance personnel. Passive islanding detection methods that use alone have considerable non-detection zone (NDZ); active islanding detection methods that use alone are that join disturbance to system, but the disturbance will cause system instability [1]. In this paper, an over/under voltage and over/under frequency detection method combines with an improved active power perturbation detection method are proposed. The photovoltaic system can be reduced non-detection zone (NDZ) with improved the power quality and reduced the total harmonic distortion (THD) through this method.

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1390
Author(s):  
Reza Bakhshi-Jafarabadi ◽  
Marjan Popov

This paper proposes a new hybrid islanding detection method for grid-connected photovoltaic system (GCPVS)-based microgrid. In the presented technique, the suspicious islanding event is initially recognized whilst the absolute deviation of the point of common coupling (PCC) voltage surpasses a threshold. After an intentional delay, a transient disturbance is injected into the voltage source inverter’s d-axis reference current to decline the active power output. As a result, the PCC voltage reduces in islanding operating mode whilst its variation is negligible in the grid presence. Therefore, the simultaneous drop of PCC voltage and active power output is used as an islanding detection criterion. The effectiveness of the proposed algorithm is investigated for various islanding and non-islanding scenarios for a practical distribution network with three GCPVSs. The simulation results in MATLAB/Simulink show successful islanding detection with a small non-detection zone within 300 ms without false tripping during non-islanding incidents. In addition to the precise and fast islanding classification, the presented scheme is realized inexpensively; its thresholds are determined self-standing, and its output power quality degradation is eminently small. Moreover, the active power output is restored to the nominal set after islanding recognition, enhancing the chance of GCPVS generation at its highest possible level in the autonomous microgrid.


Author(s):  
Abbineni Sai Subhadra ◽  
P.Linga Reddy ◽  
Shailesh . B Modi

Islanding detection of Distributed Generation (DG) is considered as one of the most important aspects when interconnecting DGs to the distribution system. It was the crucial problem in distributed generation. This detection phenomenon having a great importance. These detection methods are divided into active and passive islanding detection. These two methods are based on changing in parameters such as frequency, voltage and current harmonics. But these methods have some challenges such as reduction in power quality and large Non Detection Zone (NDZ). In this paper, the proposed method is change of Total harmonic distortion (THD) will be studied for islanding detection diagnosis. The studied system was considered by following the standard IEEE-1547 and UL-1741.The system was simulated using MATLAB/ SIMULINK.


2013 ◽  
Vol 732-733 ◽  
pp. 646-652
Author(s):  
Jian Liu ◽  
Hou Hui Fang ◽  
Xian Feng Li

This paper puts forward a novel islanding detection method based on q-axis disturbance signal injection. This method, by introducing q-axis disturbance signal injection, makes the RLC load generate frequency offset to detect the island in the case that the power network is disconnected due to certain fault.The introduced q-axis disturbance signal injection method is connected with reactive power variation and frequency variation whose values are close to zero when photovoltaic system is operated in grid-connected mode. Therefore, the suggested method has the advantage of tiny harmonic distortion and good power quality. The simulation results based on the MATLAB/Simulink software show that the novel islanding detection method can detect the island in 1 second and has little effects on the system under the condition of the set parameters.


2013 ◽  
Vol 318 ◽  
pp. 597-600
Author(s):  
Dong Xie ◽  
Xing Zhang

In the area of renewable energy technologies, islanding of distributed generation system needs to be prevented due to safety reasons and to ensure quality of power supplied to the customers. Several islanding detection methods based on passive and active schemes have been proposed in the literature. Passive methods have a large non detection zone (NDZ), While active schemes degrade power quality. This paper proposed a new passive islanding detection method which combines the Wavelet-transform and neural network techniques. This method can reduce the NDZ to zero without any perturbation that deteriorates the power quality. The simulation results show that the proposed islanding detection method is effective and robust in all kind of conditions.


Author(s):  
Abbineni Sai Subhadra ◽  
P. Linga Reddy ◽  
Shailesh B. Modi

Islanding detection of Distributed Generation (DG) is considered as one of the most important aspects when interconnecting DGs to the distribution system. It was the crucial problem in distributed generation. This detection phenomenon having a great importance. These detection methods are divided into active and passive islanding detection. These two methods are based on changing in parameters such as frequency, voltage and current harmonics. But these methods have some challenges such as reduction in power quality and large Non Detection Zone (NDZ). In this paper, the proposed method is change of Total Harmonic Distortion (THD) will be studied for islanding detection diagnosis. The studied system was considered by following the standard IEEE-1547 and UL-1741. The system was simulated using MATLAB/ SIMULINK.


2019 ◽  
Vol 9 (19) ◽  
pp. 4054 ◽  
Author(s):  
Thanh Son Tran ◽  
Duc Tuyen Nguyen ◽  
Goro FUJITA

Islanding phenomenon is one of the consequences of the emergence and development of microgrids in the power system. Injected signal cancellation is a common problem in a multi- distributed generation that has a significant influence on active islanding detection methods. In this study, this issue was analyzed by injecting a perturbation signal in the multi-photovoltaic system. Furthermore, the promising solution to eliminate injected signal cancellation was proposed in this paper. The solution was validated through mathematical explanations and simulation results.


2021 ◽  
Vol 71 (5&6) ◽  
pp. 91
Author(s):  
Dong Xie ◽  
Dajin Zang ◽  
Peng Gao ◽  
Junjia Wang ◽  
Zhu Zhu

In distributed generation systems, islanding detection is a necessary function of grid-connected inverters. In view of the performance disadvantages of traditional passive and active islanding detection methods, this paper proposes a novel passive islanding detection method. The proposed method first extracts characteristic parameters from the inverter output voltage signal and inverter output current signal through lifting wavelet transform, and then conducts the pattern recognition of these extracted characteristic parameters via BP neural network, so as to judge if there is an islanding phenomenon. As verified by the simulation and experiment results, the islanding detection method proposed in this paper is effective, and is featured by high detection speed and small non-detection zone, without affecting electric energy quality; its detection performance has been remarkably improved in comparison with that of traditional islanding detection methods.


2012 ◽  
Vol 614-615 ◽  
pp. 815-818
Author(s):  
Xue Song Zhou ◽  
Jia Rui Wu ◽  
You Jie Ma

With the increasing of the capacity of grid-connected photovoltaic (PV) power system, islanding detection becomes more prominent and significant. At present, islanding detection methods used in grid-connected photovoltaic system can be divided into passive detection methods and active detection methods these two categories, which can also be divided into a variety of methods. This paper shows a comprehensive review of islanding detection methods, classifies the methods of islanding detection, analyzes the principles and characteristics of various islanding detection methods, indicates their appropriate situations, and pointes out the prospect of islanding detection methods. In practical applications, according to the actual situation, selects one or more islanding detection methods can attain better detection effect.


2021 ◽  
Vol 11 (5) ◽  
pp. 7591-7597
Author(s):  
L. Bangar Raju ◽  
K. Subba Rao

Distributed Generators (DGs) are incorporated in the power distribution systems to develop green energies in microgrids. Islanding is a challenging task in a microgrid. Different types of islanding methods, e.g. local and remote methods, have been developed for handling this task, with local methods being easier to implement, while remote methods are communication-based and costly. The local methods are classified as passive, active, and hybrid, out of which the passive methods are more simple and economical. In this paper, a passive islanding detection method is proposed to detect single line to ground fault. This fault is considered to represent the 60 to 70% of the total un-intentional faults of this category. The available passive methods cannot detect islanding at lower power mismatches as the variations in voltage and frequency fall within thresholding values. In this method, the voltage signals are first retrieved at the targeted DG output and then the phase angle is estimated. Finally, the phase angle is differentiated to get Rate Of Change Of Voltage Phase Angle (ROCOVPA) to detect islanding, and then it is compared with the Rate Of Change Of Frequency (ROCOF) at zero percent power mismatch. Simulation results depict that the ROCOVPA is more effective than ROCOF. The proposed method not only reduces detection time and Non-Detection Zone (NDZ) but is also stable during non-islanding cases like load connection and disconnection to avoid nuisance tripping.


Sign in / Sign up

Export Citation Format

Share Document