Test Study on Mechanical Performance of the Flexible Connections of the Precast Concrete Wall Panel

2014 ◽  
Vol 900 ◽  
pp. 487-490
Author(s):  
Ruo Nan Liu ◽  
Kai Yin Zhang ◽  
Meng Lan Tao

To explore the performance of the flexible nodes between the precast concrete wall panel and the frame structure, a steel truss is used as an analogue of the frame structure to develop a test. In the test, one precast concrete wall panel was installed on the steel truss, and the connection nodes are designed to be able to slip vertically. Different horizontal forces were exerted on the steel truss to form certain drifts, and the deformation of panel and the slipping performance of the connection nodes were explored. It is found that precast concrete wall panel wont deform under the influence of the drifts, while the connection nodes between the frame structure and the panel were found to slip. The results show that the design of slipping connection node has enough reliability.

2014 ◽  
Vol 940 ◽  
pp. 284-288
Author(s):  
Ruo Nan Liu ◽  
Kai Yin Zhang ◽  
Meng Lan Tao

To explore the performance of the flexible nodes between the precast concrete exterior wall cladding panel and the frame structure, a steel truss is used as an analogue of the frame structure to develop a test. In the test, one precast concrete exterior wall cladding panel was installed on the steel truss, and the connection nodes are designed to be able to slip vertically. Different horizontal forces were exerted on the steel truss to form certain drifts, and the deformation of panel and the slipping performance of the connection nodes were explored. It is found that precast concrete exterior wall cladding panel won’t deform under the influence of the drifts, while the connection nodes between the frame structure and the panel were found to slip. The results show that the design of slipping connection node has enough reliability.


2020 ◽  
Vol 12 (19) ◽  
pp. 7907
Author(s):  
Hyun-Do Yun ◽  
Hye-Ran Kim ◽  
Won-Chang Choi

Many connection systems are available that can transfer tension and shear loads from a precast concrete wall panel to a floor slab. However, due to the insufficient anchor depth in relatively thin precast concrete panels, it is difficult to attain adequate ductility and stiffness to ensure structural integrity. Based on the authors’ previous research results, the supplementary reinforcement of embedded steel plates in precast concrete wall panels can enhance stiffness while maintaining allowable displacement and ductility. In this study, three full-size tilt-up precast concrete panels with embedded steel plates were fabricated. Lateral cyclic loads were applied to full support structures consisting of a precast concrete wall panel and a foundation. The test results were compared with the results predicted using existing code equations found in the American Concrete Institute 318-14 and the Prestressed Concrete Institute Handbooks. The test results confirm that the supplementary reinforcement of thin precast concrete wall panels can provide (i) the required strength based on current code equations, (ii) sufficient ductility, and (iii) the energy dissipation capacity to resist cyclic loading.


2022 ◽  
pp. 136943322110572
Author(s):  
Xun Chong ◽  
Pu Huo ◽  
Linlin Xie ◽  
Qing Jiang ◽  
Linbing Hou ◽  
...  

A new connection measure between the precast concrete (PC) cladding panel and PC frame structure is proposed to realize a new kind of isostatic frame-cladding system. Three full-scale PC wall-frame substructures were tested under the quasi-static load. These substructures included a bare wall-frame specimen, a specimen with a cladding panel that has no opening, and a specimen with a cladding panel that has an opening in it. The damage evolution, failure mode, load-bearing capacity, deformation capacity, and energy dissipation capacity of three specimens were compared. The results indicated that the motions of the cladding panels and the main structures were uncoupled through the relative clearance of the bottom connections, and three specimens exhibited approximately identical failure modes and seismic performance. Thus, the reliability of this new isostatic system was validated.