Evaluation of Flexural Performance in UHPC(Ultra High Performance Concrete) According to Placement Methods

2009 ◽  
Vol 417-418 ◽  
pp. 581-584 ◽  
Author(s):  
Gum Sung Ryu ◽  
Su Tae Kang ◽  
Jung Jun Park ◽  
Gyung Taek Koh

Apart from its high compressive, tensile and flexural strengths reaching approximately 200MPa, 15MPa and 35MPa, respectively, Ultra High Performance Concrete (UHPC) is characterized by its high resistance against degrading factors that can delay their penetration and diffusion speeds down to 1/20 to maximum 1/10,000 compared to ordinary concrete. UHPC also exhibits self-compaction properties with a slump flow of about 220mm. Furthermore, the most remarkable feature of UHPC is the improvement of its flexural strength and toughness through the admixing of steel fiber. Accordingly, this study evaluates the effects of the placement method on the flexural performance of UHPC. As a result, the flexural strength of UHPC appears to be extremely dependent on the placement method with variation of the maximum flexural strength up to 2 to 3 times while poor influence is observed on the initial crack strength.

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Baek-Il Bae ◽  
Hyun-Ki Choi ◽  
Chang-Sik Choi

Flexural strength evaluation models for steel fiber reinforced ultra high strength concrete were suggested and evaluated with test results. Suggested flexural strength models were composed of compression stress blocks and tension stress blocks. Rectangular stress block, triangular stress block, and real distribution shape of stress were used on compression side. Under tension, rectangular stress block distributed to whole area of tension side and partial area of tension side was used. The last model for tension side is realistic stress distribution. All these models were verified with test result which was carried out in this study. Test was conducted by four-point loading with 2,000 kN actuator for slender beam specimen. Additional verifications were carried out with previous researches on flexural strength of steel fiber reinforced concrete or ultra high strength concrete. Total of 21 test specimens were evaluated. As a result of comparison for flexural strength of section, neutral axis depth at ultimate state, models with triangular compression stress block, and strain-softening type tension stress block can be used as exact solution for ultra high performance concrete. For the conservative and convenient design of section, modified rectangular stress block model can be used with strain softening type tension stress block.


2010 ◽  
Vol 452-453 ◽  
pp. 717-720 ◽  
Author(s):  
Gum Sung Ryu ◽  
Su Tae Kang ◽  
Jung Jun Park ◽  
Kyung Taek Koh ◽  
Sung Wook Kim

This paper intends to examine the effects if the length and shape of steel fibers on the mechanical characteristics of ultra-high performance concrete (UHPC). Accordingly, the length (l) of the steel fibers with diameter (d) of 0.2 mm is varied as 13 mm, 16.3 mm and 19.5 mm and their corresponding aspect ratios (l/d) are 65, 82 and 98. Straight and wave-shaped fibers are adopted to manufacture UHPC. Thereafter, the effects of the aspect ratio and characteristics of the wave-shape of the steel fibers on the strength characteristics of UHPC are examined through compressive and flexural strength tests. The results showed small differences in the workability and compressive behavior but revealed that changing the length of the fibers and increasing the aspect ratio are improving the flexural behavior of UHPC. Specifically, the flexural strength was enhanced by 25% and the flexural toughness by 30%. Compared to rectilinear fibers, the adoption of wave-shaped fibers is seen to degrade the flexural behavior regardless of the aspect ratio. Consequently, using straight steel fibers and adopting larger aspect ratio seems advisable to improve the toughness of UHPC.


2012 ◽  
Vol 525-526 ◽  
pp. 621-624
Author(s):  
Sung Wook Kim ◽  
Jung Jun Park ◽  
Doo Youl Yoo ◽  
Young Soo Yoon

Ultra high performance concrete (UHPC), characterized by a high strength and high ductility, is also subjected to large shrinkage due to its low water-to-binder ratio and its large content in high fineness materials. The large amount of autogenous shrinkage of UHPC can induce crack on structural member when it was restrained with reinforcement and form. However, shrinkage of UHPC in plastic state is not generating confining stress, which is the main cause of initial crack. Normally, the setting time in concrete is an index to distinguish shrinkage which occur confining stress or not. An estimation of setting time is conducted in compliance with ASTM C 403 till now however, that test standard reveals error of results due to discordance of test condition as following with concrete type. This study therefore evaluated setting time of UHPC through the modified test method which was proposed by KICT. Test results and analyses proved a discrepancy of setting time between ASTM and proposed method. The proposed method put faith in evaluation of setting time in accordance with UHPC.