Shearing and Shaving Process of Stainless Steel Wire at Micro Scale

2020 ◽  
Vol 311 ◽  
pp. 74-79
Author(s):  
Chao Cheng Chang ◽  
Tzu Hsiang Hung ◽  
Jung Shu Chang

This study investigated the effects of the die clearance on the shearing and shaving processes of the stainless steel (SUS316LVM) wire at micro scale. A die set was developed and installed on a precession press equipped with a load cell and a displacement sensor to conduct experiments. By using different punches in the same die set, the specimens prepared from 316LVM stainless steel wires with 0.5 mm diameter were first sheared and then shaved. Experimental results show that the burnished area of the sheared edge increases with the reduction of the clearance between the punch and die in the shearing process. The clearance also significantly affects the load curves. Moreover, the shaving process does increase the burnished area on the shaved edge of the specimen. By an appropriate feed in the shaving process, it is possible to trim the extra material from the sheared edge that results in a nearly complete burnished surface on the shaved edge of the stainless steel wire. This research provides a basis for understanding of the die clearance effect on the shearing and shaving processes at micro scale.

2013 ◽  
Vol 746 ◽  
pp. 394-399
Author(s):  
Niwat Anuwongnukroh ◽  
Yosdhorn Chuankrerkkul ◽  
Surachai Dechkunakorn ◽  
Pornkiat Churnjitapirom ◽  
Theeralaksna Suddhasthira

The archwire is generally used in fixed appliances for orthodontic treatment to correct dental malocclusion. However, it is interesting to know whether general purpose stainless steel wire could replace commercial orthodontic archwire in orthodontic practice for economic reasons. The purpose of this study was to determine the bending properties of general purpose stainless steel wire compared with commercial orthodontic stainless steel wires after forming as an archwire for orthodontic use. The samples used in this study were 90 general purpose and 45 commercial (Highland) round stainless steel wires in 0.016, 0.018, and 0.020 sizes (30 general purpose and 15 commercial wires for each size). All 15 general purpose stainless steel wires with different sizes were formed into orthodontic archwire with a Universal Testing Machine. All samples were tested (three-point bending test) for mechanical properties. The results showed no significant difference between general purpose and commercial orthodontic wires in size 0.016 for 0.1 mm offset bending force, 0.2% yield strength, and springback. Although many mechanical properties of general purpose wires differed from commercial wires, their values conformed to other previous studies within the range of clinical acceptance. In conclusion, orthodontic formed general purpose round stainless steel wires had statistically different (p <0.05) mechanical properties from commercial orthodontic stainless steel wires (Highland) but the mechanical properties were acceptable to use in orthodontic treatment.


2016 ◽  
Vol 723 ◽  
pp. 604-609
Author(s):  
Bao Hui Li ◽  
Xiao Dan Yang

The etched stainless steel wire was prepared and explored as sorbent material for solid-phase micro extraction (SPME) coupled with gas chromatography (GC) and flame ionization detection (FID) for the trace polycyclic aromatic hydrocarbons (PAHs) determination in water. This paper explored different factors that affected the extraction efficiency of etched stainless steel wire, including the extraction time, the thermal desorption time and the thermal desorption temperature. Under the optimal conditions, six kinds of analytes, including trace biphenyl, acenaphthylene, fluorene, phenanthrene, fluoranthene and pyrene were extracted by etched stainless wire with high concentration efficiency and separated by GC-FID. In view of the high selectivity of the etched stainless steel wires for PAHs, a new SPME method was developed with the detection limits of 0.05-0.53 μg/L. The precision for the six kinds of analytes ranged from 2.6% to 8.8%. The developed etched stainless steel wires were very stable, highly selective, and reproducible for the SPME of PAHs.


2011 ◽  
Vol 378-379 ◽  
pp. 706-710 ◽  
Author(s):  
Niwat Anuwongnukroh ◽  
Surachai Dechkunakorn ◽  
Pornkiat Churnjitapirom ◽  
Ekkapot Sukhanun ◽  
Tunwa Intrarasuksanti ◽  
...  

In Thailand, commercial orthodontic stainless steel wires are imported from overseas and expensive. However, lower cost general purpose stainless steel wires, the same type and number as commercial orthodontic stainless steel wires may be used for orthodontic purposes. Objective: This study aimed to determine the physical, mechanical and chemical properties of general purpose stainless steel wire compared with commercial orthodontic stainless steel wires. Materials and Method: Two commercial orthodontic stainless steel wires (Ormco and Highland) and general purpose stainless steel wire (SUS 304H) were evaluated. The physical and mechanical properties were studied according to ISO 15841:2006 and corrosion resistance was studied according to ISO 10271:2001. Surface characteristics and composition were studied by scanning electron microscope (SEM) and electron probe micro analyzer, respectively. Results: The experiment indicated that SUS 304H had the diameter and mechanical properties in the range of orthodontic stainless steel wires. The surface characteristics SUS 304H were similar from observation by SEM magnifications but SUS 304H had lower corrosion resistance due to lower nickel content. The composition confirmed that the three samples wires were genuine type 304. Conclusion: SUS 304H properties are comparable to commercial orthodontic wire properties.


1991 ◽  
Vol 49 (10) ◽  
pp. 1074-1078
Author(s):  
Richard H. Haug ◽  
Jon P. Bradrick ◽  
Marilyn Su

2000 ◽  
Vol 3 (3) ◽  
pp. 97-98 ◽  
Author(s):  
R.S. de Biasi ◽  
A.C.O. Ruela ◽  
C.N. Elias ◽  
O. Chevitarese

Sign in / Sign up

Export Citation Format

Share Document