Eight to Ten Year Follow-Up Results of Total Knee Arthroplasty Using Electromagnetic Navigation System

2018 ◽  
Vol 53 (3) ◽  
pp. 226
Author(s):  
Jae Young Cho ◽  
Seung Hyeon Jeung ◽  
Sung Min Hong ◽  
Jeung Tak Suh ◽  
Yoon Young Choi ◽  
...  
2020 ◽  
Author(s):  
Jiaxiang Gao ◽  
Yunfei Hou ◽  
Zhichang Li ◽  
Runjun Li ◽  
Yan Ke ◽  
...  

Abstract Background: This study aimed to determine whether the iAssist navigation system (NAV) could improve the accuracy of restoring mechanical axis (MA), component positioning, and clinical outcomes compared to conventional (CON) total knee arthroplasty (TKA). Methods: A total of 301 consecutive patients (NAV: 27, CON: 274) were included. A 1:4 propensity score matching (PSM) was performed between the two groups according to preoperative demographic and clinical parameters. The postoperative MA, femoral coronal angle (FCA), femoral sagittal angle (FSA), tibial coronal angle (TCA) and tibial sagittal angle (TSA) were compared. Absolute deviations of aforementioned angles were calculated as the absolute value of difference between the exact and ideal value and defined as appropriate if within 3°, otherwise regarded as outliers. Additional clinical parameters, including the Knee Society knee and function scores (KSKS and KSFS) and range of motion (ROM), were assessed at the final follow-up (mean follow-up time was 21.88 and 21.56 months respectively for NAV and CON group). Results: A total of 98 patients/102 knees were analyzed after the PSM (NAV: 21 patients/24 knees, CON: 77 patients/78 knees). In the NAV group, the mean MA, FCA and TSA were significantly improved (p = 0.019, 0.006, <0.001, respectively). Proportions of TKAs within a ±3°deviation were significantly improved in all the postoperative radiological variables except for TCA (p = 0.003, 0.021, 0,017, 0.013, respectively for MA, FCA, FSA, and TSA). The absolute deviations of FSA and TSA were also significantly lower in the NAV group (p = 0.016, 0.048, respectively). In particular, no significant differences were found in either mean value, absolute deviation or outlier ratio of TCA between two groups. For the clinical outcomes, there were no significant differences between two groups, although KSKS, KSFS and ROM (p<0.01, respectively) dramatically improved compared to baseline. Conclusions: We suggested that the iAssist system could improve the accuracy and precision of mechanical alignment and component positioning without significant improvement of clinical outcomes. Further long-term high-quality studies are necessary to validate the results.


2012 ◽  
Vol 24 (4) ◽  
pp. 208-213 ◽  
Author(s):  
Chul Hyung Kang ◽  
Kyung Jae Lee ◽  
Ki Cheor Bae ◽  
Chul Hyun Cho ◽  
Si Wook Lee ◽  
...  

Author(s):  
Jung-Won Lim ◽  
Yong-Beom Park ◽  
Dong-Hoon Lee ◽  
Han-Jun Lee

AbstractThis study aimed to evaluate whether manipulation under anesthesia (MUA) affect clinical outcome including range of motion (ROM) and patient satisfaction after total knee arthroplasty (TKA). It is hypothesized that MUA improves clinical outcomes and patient satisfaction after primary TKA. This retrospective study analyzed 97 patients who underwent staged bilateral primary TKA. MUA of knee flexion more than 120 degrees was performed a week after index surgery just before operation of the opposite site. The first knees with MUA were classified as the MUA group and the second knees without MUA as the control group. ROM, Knee Society Knee Score, Knee Society Functional Score, Western Ontario and McMaster Universities (WOMAC) score, and patient satisfaction were assessed. Postoperative flexion was significantly greater in the MUA group during 6 months follow-up (6 weeks: 111.6 vs. 99.8 degrees, p < 0.001; 3 months: 115.9 vs. 110.2 degrees, p = 0.001; 6 months: 120.2 vs. 117.0 degrees, p = 0.019). Clinical outcomes also showed similar results with knee flexion during 2 years follow-up. Patient satisfaction was significantly high in the MUA group during 12 months (3 months: 80.2 vs. 71.5, p < 0.001; 6 months: 85.8 vs. 79.8, p < 0.001; 12 months: 86.1 vs. 83.9, p < 0.001; 24 months: 86.6 vs. 85.5, p = 0.013). MUA yielded improvement of clinical outcomes including ROM, and patient satisfaction, especially in the early period after TKA. MUA in the first knee could be taken into account to obtain early recovery and to improve patient satisfaction in staged bilateral TKA.


2020 ◽  
Vol 106 (3) ◽  
pp. 449-458
Author(s):  
Camille Bauer ◽  
Bogdan Zaharia ◽  
Florent Galliot ◽  
Jauffrey Parot ◽  
Fayçal Houfani ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 807.3-807
Author(s):  
I. Moriyama

Background:No widely accepted view or criteria currently exist concerning whether or not patellar replacement (resurfacing) should accompany total knee arthroplasty for osteoarthritis of the knee.1)2)3)Objectives:We recently devised our own criteria for application of patellar replacement and performed selective patellar replacement in accordance with this set of criteria. The clinical outcome was analyzed.Methods:The study involved 1150 knees on which total knee arthroplasty was performed between 2005 and 2019 because of osteoarthritis of the knee. The mean age at operation was 73, and the mean postoperative follow-up period was 91 months. Our criteria for application of patellar replacement are given below. Criterion A pertains to evaluation of preoperative clinical symptoms related to the patellofemoral joint: (a) interview regarding presence/absence of pain around the patella, (b) cracking or pain heard or felt when standing up from a low chair, (c) pain when going upstairs/downstairs. Because it is difficult for individual patients to identify the origin of pain (patellofemoral joint or femorotibial joint), the examiner advised each patient about the location of the patellofemoral joint when checking for these symptoms. Criterion B pertains to intense narrowing or disappearance of the patellofemoral joint space on preoperative X-ray of the knee. Criterion C pertains to the intraoperatively assessed extent of patellar cartilage degeneration corresponding to class 4 of the Outerbridge classification. Patellar replacement was applied to cases satisfying at least one of these sets of criteria (A-a,-b,-c, B and C). Postoperatively, pain of the patellofemoral joint was evaluated again at the time of the last observation, using Criterion A-a,-b,-c.Results:Patellar replacement was applied to 110 knees in accordance with the criteria mentioned above. There were 82 knees satisfying at least one of the Criterion sets A-a,-b,-c, 39 knees satisfying Criterion B and 70 knees satisfying Criterion C. (Some knees satisfied 2 or 3 of Criteria A, B and C).When the pain originating from patellofemoral joint (Criterion A) was clinically assessed at the time of last observation, pain was not seen in any knee of the replacement group and the non-replacement group.Conclusion:Whether or not patellar replacement is needed should be determined on the basis of the symptoms or findings related to the patellofemoral joint, and we see no necessity of patellar replacement in cases free of such symptoms/findings. When surgery was performed in accordance with the criteria on patellar replacement as devised by us, the clinical outcome of the operated patellofemoral joint was favorable, although the follow-up period was not long. Although further follow-up is needed, the results obtained indicate that selective patellar replacement yields favorable outcome if applied to cases judged indicated with appropriate criteria.References:[1]The Effect of Surgeon Preference for Selective Patellar Resurfacing on Revision Risk in Total Knee Replacement: An Instrumental Variable Analysis of 136,116 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.Vertullo CJ, Graves SE, Cuthbert AR, Lewis PL J Bone Joint Surg Am. 2019 Jul 17;101(14):1261-1270[2]Resurfaced versus Non-Resurfaced Patella in Total Knee Arthroplasty.Allen W1, Eichinger J, Friedman R. Indian J Orthop. 2018 Jul-Aug;52(4):393-398.[3]Is Selectively Not Resurfacing the Patella an Acceptable Practice in Primary Total Knee Arthroplasty?Maradit-Kremers H, Haque OJ, Kremers WK, Berry DJ, Lewallen DG, Trousdale RT, Sierra RJ. J Arthroplasty. 2017 Apr;32(4):1143-1147.Disclosure of Interests:None declared


Author(s):  
Hideki Mizu-uchi ◽  
Hidehiko Kido ◽  
Tomonao Chikama ◽  
Kenta Kamo ◽  
Satoshi Kido ◽  
...  

AbstractThe optimal placement within 3 degrees in coronal alignment was reportedly achieved in only 60 to 80% of patients when using an extramedullary alignment guide for the tibial side in total knee arthroplasty (TKA). This probably occurs because the extramedullary alignment guide is easily affected by the position of the ankle joint which is difficult to define by tibial torsion. Rotational direction of distal end of the extramedullary guide should be aligned to the anteroposterior (AP) axis of the proximal tibia to acquire optimal coronal alignment in the computer simulation studies; however, its efficacy has not been proven in a clinical setting. The distal end of the guide can be overly displaced from the ideal position when using a conventional guide system despite the alignment of the AP axis to the proximal tibia. This study investigated the effect of displacement of the distal end of extramedullary guide relative to the tibial coronal alignment while adjusting the rotational alignment of the distal end to the AP axis of the proximal tibia in TKA. A total of 50 TKAs performed in 50 varus osteoarthritic knees using an image-free navigation system were included in this study. The rotational alignment of the proximal side of the guide was adjusted to the AP axis of the proximal tibia. The position of the distal end of the guide was aligned to the center of the ankle joint as viewed from the proximal AP axis (ideal position) and as determined by the navigation system. The tibial intraoperative coronal alignments were recorded as the distal end was moved from the ideal position at 3-mm intervals. The intraoperative alignments were 0.5, 0.9, and 1.4 degrees in valgus alignment with 3-, 6-, and 9-mm medial displacements, respectively. The intraoperative alignments were 0.7, 1.2, and 1.7 degrees in varus alignment with 3-, 6-, and 9-mm lateral displacements, respectively. In conclusion, the acceptable tibial coronal alignment (within 2 degrees from the optimal alignment) can be achieved, although some displacement of the distal end from the ideal position can occur after the rotational alignment of the distal end of the guide is adjusted to the AP axis of the proximal tibia.


Author(s):  
Cristina Dauder Gallego ◽  
Irene Blanca Moreno Fenoll ◽  
José Luis Patiño Contreras ◽  
Francisco Javier Moreno Coronas ◽  
María del Carmen Torrejón de la Cal ◽  
...  

Author(s):  
Silvan Hess ◽  
Timo Fromm ◽  
Filippo Schiapparelli ◽  
Lukas B. Moser ◽  
Emma Robertson ◽  
...  

Abstract Purpose The main purpose of this study was to determine whether there is a correlation between the change of tibial tuberosity-trochlear groove (TT-TG) distance and clinical outcomes after total knee arthroplasty (TKA). Methods A total of 52 knees undergoing TKA due to primary osteoarthritis were included in this retrospective study. All patients had pre- and postoperative CT scans. TT-TG distance was measured by two independent observers and the following alignment parameters were measured: hip-knee ankle angle (HKA), femoral mechanical angle (FMA), tibial mechanical angle (TMA), and posterior condylar angle (PCA). Clinical outcome was assessed using Knee Society Score (KSS) pre- and post-operatively and at a minimum of 12-month follow-up. Evidence of AKP was noted from follow-up reports. Pre- and postoperative scores were compared using a paired Student t-test. Pearson correlations were calculated to assess the influence of TT-TG on clinical outcome and of alignment parameters on the change in TT-TG. TT-TG between patients with and without AKP was compared using unpaired Student’s t-test (p < 0.05). Results Neither the absolute postoperative TT-TG nor the amount of change in TT-TG correlated with the post-operative KSS or the change in KSS. Post-operative TT-TG and change in TT-TG did not differ significantly between patients with and patients without AKP. Only the change in FMA showed a correlation with the change in TT-TG (p = 0.01, r = 0.36). Conclusion Despite a missing correlation between outcomes and TT-TG distance in this study, excessive TT-TG distance should be avoided. Furthermore, surgeons need to be aware that changes in femoral joint line orientation might affect TT-TG distance.


Sign in / Sign up

Export Citation Format

Share Document