electromagnetic navigation system
Recently Published Documents


TOTAL DOCUMENTS

54
(FIVE YEARS 24)

H-INDEX

11
(FIVE YEARS 2)

2021 ◽  
pp. 219256822110255
Author(s):  
Derong Xu ◽  
Xuexiao Ma ◽  
Lei Xie ◽  
Chuanli Zhou ◽  
Biao Kong

Study Design: Retrospective database study. Objectives: To compare the accuracy and safety of 2 types of a computer-assisted navigation system for percutaneous pedicle screw placement during endoscopic lumbar interbody fusion. Methods: From May 2019 to January 2020, data of 56 patients who underwent Endo-LIF with a robot-assisted system and with an electromagnetic navigation system were compared. The pedicles in all patients were subjected to postoperative CT scan to assess screw correction by measuring the perpendicular distance between the pedicle cortical wall and the screw surface. The registration and matching time, guide-wire insertion time, the entire surgery time, and X-ray exposure time were recorded. Results: In the robot-assisted group, 25 cases with 100 percutaneous pedicle screws were included, and the excellent and good rate was 95%. In the electromagnetic navigation group, 31 cases with 124 screws were included, and the excellent rate was 97.6%. There was no statistical difference between the two groups ( P > 0.05). The registration time and the total time for the surgery also showed no statistical differences ( P > 0.05). The main difference between the two groups was the guide-wire insertion time and the X-ray exposure time ( P < 0.05). Conclusions: Both electromagnetic navigation and robot-assisted are safe and efficient for percutaneous pedicle screw placement. Electromagnetic navigation system has obvious advantages over robot-assisted in terms of faster guide-wire placement and less X-ray exposure. Robot-assisted for percutaneous pedicle screw placement offers a preoperative planning system and a stable registration system, with obvious drawbacks of a strict training curve.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3357
Author(s):  
Kilian O’Donoghue ◽  
Herman Alexander Jaeger ◽  
Padraig Cantillon-Murphy

In recent times, the use of electromagnetic tracking for navigation in surgery has quickly become a vital tool in minimally invasive surgery. In many procedures, electromagnetic tracking is used in tandem with X-ray technology to track a variety of tools and instruments. Most commercially available EM tracking systems can cause X-ray artifacts and attenuation due to their construction and the metals that form them. In this work, we provide a novel solution to this problem by creating a new radiolucent electromagnetic navigation system that has minimal impact on -ray imaging systems. This is a continuation of our previous work where we showed the development of the Anser open-source electromagnetic tracking system. Typical electromagnetic tracking systems operate by generating low frequency magnetic fields from coils that are located near the patient. These coils are typically made from copper, steel, and other dense radiopaque materials. In this work, we explore the use of low density aluminum to create these coils and we demonstrate that the effect on X-ray images is significantly reduced as a result of these novel changes in the materials used. The resulting field generator is shown to give at least a 60% reduction in the X-ray attenuation in comparison to our earlier designs. We verify that the system accuracy of approximately 1.5 mm RMS error is maintained with this change in design.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Oliver D Jungesblut ◽  
Josephine Berger-Groch ◽  
Michael Hoffmann ◽  
Malte Schroeder ◽  
Kara L. Krajewski ◽  
...  

Abstract Background Retrograde drilling in osteochondrosis dissecans (OCD) is a widely used surgical intervention. A radiation-free electromagnetic navigation system (ENS)-based method was compared with the standard freehand fluoroscopic (SFF) method regarding clinical applicability. Methods We performed a clinical cohort study at a department of Orthopaedics in a Level 1 children’s hospital with 40 patients (20 SFF and 20 ENS). Retrograde drilling of the talar dome was used in patients with unstable medial OCD (MRI stage 2 according to Hepple’s revised classification; stage 2 according to the International Cartilage Repair Society). The outcome measurements were: (a) Intraoperative fluoroscopy exposure and length of surgery and (b) Postoperative serial follow-up MRIs every 6 months. Results 22 female and 18 male patients aged 13.8 ± 1.6 years (range: 11–17 years) were included. Using the ENS technique, length of surgery was significantly reduced to 20.2 ± 6.4 min compared to 36.1 ± 11.8 min (p < 0.01) for the SFF technique. The average x-ray radiation time for the SFF technique was 23.5 ± 13.5 sec and 1.9 ± 1.7 sec for the ENS technique (p < 0.01). Radiation exposure was significantly reduced from 44.6 ± 19.7 mSv (SFF technique) to 5.6 ± 2.8 mSv (ENS technique) (p < 0.01). Intraoperative perforation of cartilage occurred once in the SFF group. Correct placement of the drilling channel was verified in all patients on follow-up MRI after six months and a timely healing was seen after two years. Conclusions The ENS method provides for a significant reduction in length of surgery and radiation exposure. ENS was without intraoperative cartilage perforation. The clinical and radiological follow-up parameters are comparable for SFF- and ENS-guided retrograde drilling. Trial registration WF – 085/20, 05/2020 “retrospectively registered” https://www.aerztekammer-hamburg.org/ethik_kommission.html.


2021 ◽  
Vol 20 (4) ◽  
pp. 373-382
Author(s):  
Hannah Keeble ◽  
José Pedro Lavrador ◽  
Noémia Pereira ◽  
Kornelius Lente ◽  
Christian Brogna ◽  
...  

Abstract BACKGROUND A recent influx of intraoperative technology is being used in neurosurgery, but few reports investigate the accuracy and safety of these technologies when used simultaneously. OBJECTIVE To assess the ability to use an electromagnetic navigation system alongside multimodal intraoperative neurophysiological monitoring (IONM). METHODS Single-institution prospective cohort study of patients requiring craniotomy for brain tumor resection operated using an electromagnetic navigation system (AxiEM, Medtronic®). motor evoked potentials, somatosensory evoked potentials (SSEPs), electroencephalography, and electromyography were recorded and analyzed with AxiEM on (with/without filters) and off. The neurological outcomes of the patients were recorded. RESULTS A total of 15 patients were included (8 males/7 females, mean age 52.13 yr). Even though the raw acquisition is affected by the electromagnetic field (particularly SSEPs), no significant difference was detected in the morphology, amplitude, and latency of the different monitoring modalities (AxiEM off vs on) after the appropriate software filter application. Adjustments to the frequency of SSEP stimulation and number of averages, and reductions to the low-pass filters were applied. Notch filters were used appropriately and changes to the physical setup of the IONM and electromagnetic navigation system equipment reduced noise. Postoperatively, none of the patients developed new focal deficits; 7 patients showed improvement in their motor deficit (4 recovered fully). CONCLUSION The information provided by the IONM in intracranial neurosurgery patients whilst also using electromagnetic navigation systems is reliable for monitoring, mapping, and detecting intraoperative complications, provided that the appropriate software filters and tools are applied.


2020 ◽  
Author(s):  
Josephine Berger-Groch ◽  
Oliver D Jungesblut ◽  
Michael Hoffmann ◽  
Malte Schroeder ◽  
Kara L Krajewski ◽  
...  

Abstract Background: Retrograde drilling in osteochondrosis dissecans (OCD) is a widely used surgical intervention. A radiation-free electromagnetic navigation system (ENS)-based method was compared with the standard freehand fluoroscopic (SFF) method regarding clinical applicability.Methods: We performed a clinical cohort study at a department of Orthopaedics in a Level 1 children’s hospital with 40 patients (20 SFF and 20 ENS). Retrograde drilling of the talar dome was used in patients with unstable medial OCD (MRI stage 2 according to Hepple’s revised classification; stage 2 according to the International Cartilage Repair Society). The outcome measurements were: a) Intraoperative fluoroscopy exposure and length of surgery and b) Postoperative serial follow-up MRIs every 6 months.Results: 22 female and 18 male patients aged 13.8 ± 1.6 years (range: 11-17 years) were included. Using the ENS technique, length of surgery was significantly reduced to 20.2 ± 6.4 min compared to 36.1 ± 11.8 min (p<0.01) for the SFF technique. The average x-ray radiation time for the SFF technique was 23.5 ± 13.5 sec and 1.9 ± 1.7 sec for the ENS technique (p<0.01). Radiation exposure was significantly reduced from 44.6 ± 19.7 mSv (SFF technique) to 5.6± 2.8 mSv (ENS technique) (p<0.01). Intraoperative perforation of cartilage occurred once in the SFF group. Correct placement of the drilling channel was verified in all patients on follow-up MRI after six months and a timely healing was seen after two years. No differences were detected on follow-up MRI between the two methods.Conclusions: The ENS method provides for a significant reduction in length of surgery and radiation exposure. ENS was without intraoperative cartilage perforation. The clinical and radiological follow-up parameters are comparable for SFF- and ENS-guided retrograde drilling.Trial registration: WF – 085/20, 05/2020 “retrospectively registered”


Sign in / Sign up

Export Citation Format

Share Document