scholarly journals Biliary Stent Migration to Hepatic Duct–Case Report of a Late Complication

2015 ◽  
Vol 8 ◽  
pp. CCRep.S18975
Author(s):  
Amir Houshang Mohammad Alizadeh ◽  
Kianoush Donboli ◽  
Mehran Khodakarami ◽  
Salar Baghbani ◽  
Mohammad Reza Zali

Endoscopic retrieval of proximally migrated biliary plastic stents may be technically challenging and sometimes unsuccessful. Here we report the case of a 59-year-old woman with a migrated biliary stent in the right hepatic duct, which was diagnosed after the patient presented with cholangitis. The patient presented with constant abdominal pain in the right upper quadrant lasting for two days, along with nausea and bilious vomiting. The stent was retrieved by a polypectomy snare after failure of biliary basket and forceps. We performed a novel procedure for extraction of a migrated plastic stent, by using a polypectomy snare.

2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Oluwatobi Onafowokan ◽  
Dabanjan Bandyopadhyay ◽  
Dale Johnson ◽  
Hugo J. R. Bonatti

Background. Lumbar hernias are rare abdominal hernias. Surgery is the only treatment option but remains challenging. Posterior incisional hernias are even rarer especially with incarceration of intra-abdominal contents.Case Presentation. A 68-year old female presented with a 3-day history of worsening acute abdominal pain and distension, with multiple episodes of emesis. A CT scan indicated a large incarcerated posterolateral abdominal hernia. The patient had a history of resection of a sarcoma on her back as a child and also received chemotherapy and radiation. During emergency laparoscopy, a hemorrhagic small bowel segment incarcerated in the hernia was reduced and resected, and the distended small bowel was decompressed. An elective hernia repair was scheduled. After temporary clinical improvement, the patient again developed abdominal pain, distention, and emesis. During emergency laparotomy, a large hematoma in the right flank was found and partially evacuated. The right colon was mobilized out of the hernia and the duodenum was kocherized. A20×20cm BIO-A mesh was placed on top of the Gerota fascia and cranially tucked under liver segment VI. Anteriorly, the mesh was fixated with absorbable tacks. The duodenum and colon were placed into the mesh pocket. A postoperative CT scan identified a 2 cm pseudoaneurysm of a side branch of a lumbar artery, and the bleeding source was embolized. The postoperative course was complicated byClostridium difficile-associated colitis, but ultimately, the patient recovered fully. At 6-month follow-up, there was no evidence for a recurrent hernia.Discussion. There is a paucity of literature concerning lumbar incisional hernias. Repair with bioabsorbable mesh seems feasible, but longer follow-up is necessary as the mesh was placed in an unusual fashion due to the retroperitoneal hematoma. The exact cause of the hemorrhage is unclear and may have been caused during the initial incarceration, during surgery, or may be a late complication of her previous radiation.


2019 ◽  
Vol 07 (09) ◽  
pp. E1105-E1114 ◽  
Author(s):  
Kazunari Nakahara ◽  
Yosuke Michikawa ◽  
Ryo Morita ◽  
Keigo Suetani ◽  
Nozomi Morita ◽  
...  

Abstract Background and study aims Biliary plastic stents are generally substituted for gallbladder stents in endoscopic transpapillary gallbladder stenting (EGBS), there is no sufficient evidence about what type of plastic stent is suitable. We examined outcomes of EGBS using standard biliary stents and a novel stent for acute cholecystitis and evaluated the efficacy of the novel stent. Patients and methods Seventy patients with acute cholecystitis in whom EGBS was performed were evaluated retrospectively. We performed EGBS in 23 patients using the novel stent (novel stent group) and 47 patients using standard biliary stents (pigtail: 35, straight: 12) (control group). In the two groups, we examined outcomes of EGBS. Results There were no significant differences in patient backgrounds or rates of technical success, clinical success, or early adverse events (AE) between the novel stent group and the control groups. However, rates of late AEs were 4.3 % in the novel stent group (liver abscess: 1) and 40.4 % in the control group (stent migration: 15, recurrence of cholecystitis: 4), indicating a significantly higher rate in the control group (P = 0.004). The rate of stent migration was significantly higher in the control group (P = 0.006). Multivariate analysis identified a straight type stent as the risk factor for stent migration (odds ratio: 8.81, 95 % confidence interval: 1.66 – 46.83). Conclusions The novel stent had significantly lower rates of late AEs and stent migration. Thus, for long-term stent placement, the novel stent was more effective than traditional biliary stents.


2018 ◽  
Vol 06 (04) ◽  
pp. E489-E494
Author(s):  
Chang-Il Kwon ◽  
Mark Gromski ◽  
Hyoung-Chul Oh ◽  
Jeffrey Easler ◽  
Ihab El Hajj ◽  
...  

Abstract Background and study aims In plastic stent insertion for treatment of post-cholecystectomy bile leak, stent migration may be more common due to the absence of a shelf to anchor the stent. We evaluated how adding a flap to straight plastic stents for this indication might influence the rate of stent migration when compared to use of conventional plastic stents. Patients and methods This is a retrospective study including patients referred for ERCP for treatment of post-cholecystectomy bile leak. Patients with a customized anti-migration flap stent had the additional flap created on the distal end of straight plastic stents, intended to aid in anchoring in the distal supra-sphincteric biliary duct. The primary endpoint is stent migration events. The secondary endpoint is bile leak resolution after first ERCP session. Results Thirty-two patients were treated with the experimental additional flap stents and 225 patients were treated with standard straight biliary stents. The total failure rate of bile leak resolution after a single endoscopic treatment for all treated was 10.5 % (27/257) and the total stent migration rate for all enrolled was 15.2 % (39/257). Stent migration rate was lower in the additional flap stent group than in the conventional group (3.1 % vs. 16.9 %, respectively, P = 0.04). Furthermore, significantly more patients had resolution of their bile leak after the first ERCP session in the group with the additional flap (100 % vs. 88 %, respectively, P = 0.03). Conclusion A plastic biliary stent with an extra flap may have improved performance with regard to stent migration and resolution of bile leak over standard plastic biliary stents.


2020 ◽  
Vol 9 ◽  
pp. 1809
Author(s):  
Arash Dooghaie Moghadam ◽  
Niloofar Razavi-Khorasani ◽  
Pegah Eslami ◽  
Sandra Saeedi ◽  
Ermia Farokhi ◽  
...  

Background: Plastic biliary stent placement has been widely used as a safe approach for the management of hilar neoplasms or the dilation of benign biliary obstruction. Despite the complexity of this procedure, this approach is followed by a few complications. The incidence rate of stent migration is about 10%. In a majority of cases, the migrated stents are retained within the gastrointestinal tract and pass through the intestine with no complication or need for medical intervention. Case Report: In this paper, we described the case of the migrated biliary stent with prolonged abdominal pain, which was removed successfully by using double-balloon. Conclusion: In the case of patient with prolonged abdominal pain and previous history of biliary stent placement, migration of stent should be considered as differential diagnosis and Double-Balloon Enteroscopy can be a safe approach in those cases.[GMJ.2020;9:e1809]


2013 ◽  
Vol 2013 (sep10 1) ◽  
pp. bcr2013009124-bcr2013009124 ◽  
Author(s):  
M. Jones ◽  
B. George ◽  
J. Jameson ◽  
G. Garcea

2020 ◽  
Vol 99 (3) ◽  
pp. 131-135

Introduction: Abdominal emergencies occur in pregnant women with the rate of 1:500−635 pregnancies. Such conditions usually develop from full health and worsen rapidly. Symptoms are often similar to those in physiological pregnancy (abdominal pain, vomiting, constipation). The diagnostic process is thus difficult and both the mother and her child are at risk. Our aim was to evaluate the frequency of abdominal emergencies in the Department of Surgery, University Hospital in Pilsen and to consider their impact on pregnancy and on the newborn. Methods: We acquired a set of patients by retrograde collection of data. We searched for pregnant patients suspected of developing an abdominal emergency admitted to the Department of Surgery, Faculty of Medicine, Pilsen between 2004 and 2015. We evaluated a number of clinical signs to statistically describe the set. Results: The set included 121 patients; 42 of the patients underwent a surgical procedure and 79 received conservative treatment. 38 patients underwent appendectomy; 6 appendixes were with no pathologies. McBurney’s incision was an approach of choice in most cases. The most frequent symptom was pain in the right lower abdominal quadrant. The foetus has been lost in none of the cases. Conclusion: Acute appendicitis was the most frequent abdominal emergency in our set and also the most frequent reason for surgical intervention. The most specific sign was pain in the right lower abdominal quadrant. No impact of appendicitis or appendectomy on the health of the newborn has been observed. Even though abdominal emergencies in pregnancy are relatively rare, the results of the department are very good.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sang Hoon Lee ◽  
Yeon Suk Kim ◽  
Eui Joo Kim ◽  
Hee Seung Lee ◽  
Jeong Youp Park ◽  
...  

AbstractChronic pancreatitis (CP) related main pancreatic duct (MPD) stricture has been a challenge for endoscopists. Fully covered self-expandable metal stents (FC-SEMS) has been tried in CP patients, but the efficacy and safety are still controversial. Thus, we aim to compare the long-term clinical efficacy of FC-SEMS vs. plastic stent placement in persistent MPD strictures secondary to CP. Between 2007 and 2018, 80 chronic pancreatitis patients (58 males, median age 49 years), who underwent endoscopic placement of FC-SEMS (n = 26) and plastic stent (n = 54) for persistent MPD strictures after at least 3 months of initial single plastic stenting, were retrospectively analyzed during a median follow-up duration of 33.7 months. As a result, MPD stricture resolution rate was statistically higher in FC-SEMS group (87.0% vs. 42.0%, p < 0.001). Although immediate complications occurred similarly (38.5% vs. 37.0%, p = 0.902), spontaneous migration (26.9%) and de novo strictures (23.1%) were pronounced delayed complications in FC-SEMS group. Pain relief during follow-up was significantly higher in FC-SEMS group (76.9% vs. 53.7%, p = 0.046). The total procedure cost was similar in both groups ($1,455.6 vs. $1,596.9, p = 0.486). In comparison with plastic stent, FC-SEMS placement for persistent MPD strictures had favorable long-term clinical efficacy, with its typical complications like spontaneous migration and de novo strictures.


Sign in / Sign up

Export Citation Format

Share Document