scholarly journals Approximate and Invariant Solutions of a Mathematical Model Describing a Simple One-Dimensional Blood Flow of Variable Density

2017 ◽  
Vol 05 (06) ◽  
pp. 1335-1354
Author(s):  
Ranis Ibragimov ◽  
Nail Ibragimov ◽  
Pirooz Mohazzabi
2007 ◽  
Vol 7 (4) ◽  
pp. 347-359 ◽  
Author(s):  
Gaurav Ameta ◽  
Joseph K. Davidson ◽  
Jami J. Shah

A new mathematical model for representing the geometric variations of lines is extended to include probabilistic representations of one-dimensional (1D) clearance, which arise from positional variations of the axis of a hole, the size of the hole, and a pin-hole assembly. The model is compatible with the ASME/ ANSI/ISO Standards for geometric tolerances. Central to the new model is a Tolerance-Map (T-Map) (Patent No. 69638242), a hypothetical volume of points that models the 3D variations in location and orientation for a segment of a line (the axis), which can arise from tolerances on size, position, orientation, and form. Here, it is extended to model the increases in yield that occur when maximum material condition (MMC) is specified and when tolerances are assigned statistically rather than on a worst-case basis; the statistical method includes the specification of both size and position tolerances on a feature. The frequency distribution of 1D clearance is decomposed into manufacturing bias, i.e., toward certain regions of a Tolerance-Map, and into a geometric bias that can be computed from the geometry of multidimensional T-Maps. Although the probabilistic representation in this paper is built from geometric bias, and it is presumed that manufacturing bias is uniform, the method is robust enough to include manufacturing bias in the future. Geometric bias alone shows a greater likelihood of small clearances than large clearances between an assembled pin and hole. A comparison is made between the effects of choosing the optional material condition MMC and not choosing it with the tolerances that determine the allowable variations in position.


1995 ◽  
Vol 03 (03) ◽  
pp. 653-659 ◽  
Author(s):  
J. J. NIETO ◽  
A. TORRES

We introduce a new mathematical model of aneurysm of the circle of Willis. It is an ordinary differential equation of second order that regulates the velocity of blood flow inside the aneurysm. By using some recent methods of nonlinear analysis, we prove the existence of solutions with some qualitative properties that give information on the causes of rupture of the aneurysm.


1984 ◽  
Vol 15 (4-5) ◽  
pp. 243-252 ◽  
Author(s):  
Helén Engelmark

A one-dimensional mathematical model is used to simulate the process of snow-melt infiltration in unsaturated frozen silt. Hydraulic and thermal parameters are mainly based on data given in the literature. Field observations in a watershed (of area 1.8 km2) are compared with simulated data and consequences on snow melt run-off are discussed.


2014 ◽  
Vol 42 (5) ◽  
pp. 1012-1023 ◽  
Author(s):  
Paris Perdikaris ◽  
George Em. Karniadakis

2008 ◽  
Vol 74 (737) ◽  
pp. 142-148 ◽  
Author(s):  
Kentaro NARUMI ◽  
Tsutomu NAKANISHI ◽  
Atsushi SHIRAI ◽  
Toshiyuki HAYASE

1973 ◽  
Vol 95 (2) ◽  
pp. 250-256 ◽  
Author(s):  
T. E. Cooper ◽  
J. P. Groff

This paper discusses the use of heat for producing clinical lesions in tissue and presents the design and analysis of a resistively heated surgical probe. The probe surface temperature is accurately maintained and controlled by using a Wheatstone bridge. The probe was embedded in a clear agar–water test medium, and the temperature field generated by the probe was measured with liquid crystals, a material that provides a visual display of certain isotherms. Experimental results compare within approximately 10 percent of a two-dimensional numerical solution. A one-dimensional theoretical model is also developed which examines the influence of blood flow on the temperature field.


Sign in / Sign up

Export Citation Format

Share Document