scholarly journals Cranioplasty of Calvarial Skull Defects: A Comparative Study between Using Three Dimensional Custom-Made Cranioprostheses versus Hand-Made Bone Cement in Restoring Skull Configuration

2019 ◽  
Vol 09 (03) ◽  
pp. 314-326
Author(s):  
Mohamed Gaber Abdel Tawab ◽  
Mostafa A. Latif, Ashraf Abdel Latif Osman
2013 ◽  
Vol 5 ◽  
pp. JCNSD.S11106 ◽  
Author(s):  
Jarle Sundseth ◽  
Jon Berg-Johnsen

Cranial defects can be caused by injury, infection, or tumor invasion. Large defects should be reconstructed to protect the brain and normalize the cerebral hemodynamics. The conventional method is to cover the defect with bone cement. Custom-made implants designed for the individual patient are now available. We report our experience with one such product in patients with large cranial defects (>7.6 cm in diameter). A CT scan with 2 mm slices and a three-dimensional reconstruction were obtained from the patient. This information was dispatched to the company and used as a template to form the implant. The cranial implant was received within four weeks. From 2005 to 2010, custom-made cranial implants were used in 13 patients with large cranial defects. In 10 of the 13 patients, secondary deep infection was the cause of the cranial defect. All the implants fitted well or very well to the defect. No infections were seen after implantation; however, one patient was reoperated on for an epidural hematoma. A custom-made cranial implant is considerably more expensive than an implant made of bone cement, but ensures that the defect is optimally covered. The use of custom-made implants is straightforward and timesaving, and they provide an excellent medical and cosmetic result.


2021 ◽  
Vol 12 ◽  
pp. 587
Author(s):  
Ahmed Hosameldin ◽  
Ashraf Osman ◽  
Mohamed Hussein ◽  
Amr Fathy Gomaa ◽  
Mostafa Abdellatif

Background: An optimal reconstruction of calvarial skull defects is a challenge for neurosurgeons, and the strategy used to achieve the best result remains debatable. Therefore, we conducted this study to compare the esthetic and functional outcome of custom-made three-dimensional (3D) cranioprostheses to handmade bone cement in reconstructing calvarial skull defects. Methods: We included 66 patients above 10 years of age with calvarial skull defects and undergoing reconstruction: 33 were enrolled in the custom-made 3D implants group and 33 in the handmade implants group in the period from August 2017 to December 2020 in the neurosurgery department of Fayoum University Hospital. Results: Complete success of the esthetic end-point was insignificantly higher in the custom-made 3D prostheses group based on the doctor’s and patients’ assessment (60.6% vs. 42.4%; 33.3% vs. 9.1%, P > 0.05), respectively. Complete success of the functional end-point was significantly higher in the custom-made 3D group compared to the handmade cement bone group according to the doctor’s and patients’ assessment (60.6% vs. 0%; 21.2% vs. 0%, P < 0.05). There were no late complications noted in the custom-made 3D prosthesis group, whereas 50% of the handmade bone group had late complications (P < 0.05). Full improvement of the symptoms of the “syndrome of trephined” was achieved in the 3D custom-made group compared to the handmade bone cement group (20% vs. 0%). Conclusion: Cranioplasty using three dimensional customs made PEEK prosthesis is a reliable method which saves operative time, lowers cost and provides less complications if compared with other cranioplasty techniques. Custom-made 3D cranioprostheses are better than handmade bone cement in reconstructing calvarial defects in terms of esthetic and functional outcome as well as complications.


2021 ◽  
Vol 18 (3) ◽  
pp. 623-636
Author(s):  
Mohammad Hossein Esnaashary ◽  
Masoud Karfarma ◽  
Hamid Reza Rezaie ◽  
Alireza Khavandi ◽  
Jafar Javadpour

2021 ◽  
pp. 112067212110000
Author(s):  
Annabel LW Groot ◽  
Jelmer S Remmers ◽  
Roel JHM Kloos ◽  
Peerooz Saeed ◽  
Dyonne T Hartong

Purpose: Recurrent contracted sockets are complex situations where previous surgeries have failed, disabling the wear of an ocular prosthesis. A combined method of surgery and long-term fixation using custom-made, three-dimensional (3D) printed conformers is evaluated. Methods: Retrospective case series of nine patients with recurrent excessive socket contraction and inability to wear a prosthesis, caused by chemical burns ( n = 3), fireworks ( n = 3), trauma ( n = 2) and enucleation and radiotherapy at childhood due to optic nerve glioma ( n = 1) with three average previous socket surgeries (range 2–6). Treatment consisted of a buccal mucosal graft and personalized 3D-printed conformer designed to be fixated to the periosteum and tarsal plates for minimal 2 months. Primary outcome was the retention of an ocular prosthesis. Secondary outcome was the need for additional surgeries. Results: Outcomes were measured at final follow-up between 7 and 36 months postoperatively (mean 20 months). Eight cases were able to wear an ocular prosthesis after 2 months. Three cases initially treated for only the upper or only the lower fornix needed subsequent surgery for the opposite fornix for functional reasons. Two cases had later surgery for cosmetic improvement of upper eyelid position. Despite pre-existing lid abnormalities (scar, entropion, lash deficiency), cosmetic outcome was judged highly acceptable in six cases because of symmetric contour and volume, and reasonably acceptable in the remaining two. Conclusions: Buccal mucosal transplant fixated with a personalized 3D-designed conformer enables retention of a well-fitted ocular prosthesis in previously failed socket surgeries. Initial treatment of both upper and lower fornices is recommended to avoid subsequent surgeries for functional reasons.


2016 ◽  
Vol 25 (10) ◽  
pp. 1607-1615 ◽  
Author(s):  
Matthijs Jacxsens ◽  
Alexander Van Tongel ◽  
Heath B. Henninger ◽  
Brecht De Coninck ◽  
Andreas M. Mueller ◽  
...  

Author(s):  
Ankit Chaudhary ◽  
Virendra Deo Sinha ◽  
Sanjeev Chopra ◽  
Jitendra Shekhawat ◽  
Gaurav Jain

Abstract Background Cranioplasty is performed to repair skull defects and to restore normal skull anatomy. Optimal reconstruction remains a topic of debate. Autologous bone flap is the standard option but it may not be available due to traumatic bone fractures, bone infection, and resorption. The authors present their experience with prefabrication of precise and low-cost polymethyl methacrylate (PMMA) mold using three-dimensional (3D) digital printing. Methods A total of 30 patients underwent cranioplasty between March 2017 and September 2019 at Sawai Man Singh Medical College Jaipur, India. Preoperative data included diagnosis for which decompressive craniectomy was done and Glasgow coma scale score. Intraoperative data included operating time. Postoperative data included cosmetic outcome in the form of cranial contour and margins, complications such as infection, seroma, implant failure, wound dehiscence, and hematoma. Results Patient age at cranioplasty ranged from 12 to 63 years with a mean age of 36.7 years. The mean operating time was 151.6 minutes (range 130–190 minutes). The mean follow-up period was 8 months (range 6–13 months). Postoperative wound dehiscence developed in one case (3.3%). Cranial contour and approximation of the margins were excellent and aesthetic appearance improved in all patients. Conclusion Low-cost PMMA implant made by digital 3D printer mold is associated with reconstruction of the deformed skull contour giving satisfactory results to the patient and his family members, at a low cost compared with other commercially available implants. This technique could be a breakthrough in cranioplasty.


Sign in / Sign up

Export Citation Format

Share Document