Prediction of High Temperature Viscosities of Polymer Solutions up to 107 sec-1 Shear Rates

1991 ◽  
Author(s):  
E.E. Klaus ◽  
J.L. Duda ◽  
V. Bala
2009 ◽  
Vol 614 ◽  
pp. 197-200 ◽  
Author(s):  
Shao Peng Wu ◽  
Gang Liu ◽  
Jin Gang Wang ◽  
Yuan Zhang

In this study, the influence of some inorganic nanoparticles on the properties of bitumen binder was investigated. Three types of particles at nanometer level, calcium carbonate powder, graphite and carbon black, were introduced to modify bitumen respectively. The modified binders were prepared using a laboratory high-shear mixer. A dynamic shear rheometer (DSR) was adopted to characterize the properties of modified binders, including their rheological parameters and dynamic viscosity, over a certain range sweeps of temperatures, frequencies and shear rates. It was found that the addition of the nanoparticles increased the binder’s elasticity at low temperature which might negatively influence its resistance to crack. However the decrease of phase angle at high temperature might improve its deformation resistance. The shear rate dependence of dynamic viscosity for the binders depended on the type of nanoparticle. The research results indicated that the addition of nanoparticles to bitumen binder can change its physical properties to some extent and its potential should be researched further.


1984 ◽  
Vol 24 (03) ◽  
pp. 249-255 ◽  
Author(s):  
Jaime A. Lescarboura ◽  
Thomas R. Sifferman ◽  
Harry A. Wahl

Abstract A flow loop was used to evaluate the stability of fracturing fluids at high temperatures. The design provides enough pressure to prevent vaporization of water-base systems up to 350F [177C]. Crosslinked polymer systems from four service companies were evaluated at 180 and 245F [82 and 118C]. The tests showed that crosslinked fracturing fluids degrade with temperature and shear, losing much of their viscosity and proppant-carrying capacity in a few hours. Thermal stability is a major factor in selecting gels for fracturing deep, high-temperature reservoirs. Introduction Job failures in deep, hot wells can be caused by "sand-outs." These sandouts, or "screenouts," can result from inadequate carrying capacity (reduced viscosity) or too high a fluid loss (dehydration) for the polymer loading of the fracturing fluid. This study investigates the reduction in viscosity of crosslinked fracturing fluids with time at temperatures and shear rates approximating downhole conditions. A flow loop was used to investigate the rheological properties of fracturing fluids as a function of time under shear at temperatures as high as 245F [118C]. The pipe loop configuration was chosen because our field experience indicated that rotational viscometers were too "kind" to fracturing systems. We experienced sandouts that should not have happened if the crosslinked fracturing systems used had the flow characteristics that rotational viscometry indicated they had. The flow loop configuration also avoids some of the problems inherent in rotational viscometers, such as fluid climbing the shaft and contamination of the sample. Flow loops have been used to condition and evaluate drilling fluids at high temperatures. However, some of these instruments were not designed to give quantitative results. Our instrument permits measurement of apparent viscosity at known shear rates, flow index, and consistency index, all at high temperatures. This paper describes the flow loop, test procedures used, and results obtained. The flow loop gives reproducible results at high temperatures and allows the evaluation of the rheological properties of fracturing fluids under flow conditions nearer those encountered in actual fracturing jobs than do rotational, high-temperature instruments. Previous Work Previous Work Very little information has been reported on temperature stability of crosslinked fracturing fluids, especially under shearing conditions. Elbel and Thomas discussed the use of viscosity stabilizers for high-temperature fracturing. Conway et al. subjected crosslinked fracturing fluids to shear and to high temperatures. Hsu and Conway described the development of more stable crosslinked gels for use in deep, hot formations. All these investigators used the Fann 50 viscometer for their work, although Conway et al. used a pump to shear the samples before testing. Flow Loop Description The flow loop was built to evaluate the flow properties of drilling fluids, fracturing fluids, heavy crudes, and waxy crudes. The current test system can operate up to 350F [177C] and 250 psi [1,724 kPa]. The flow loop schematic is shown in Fig. 1. The test fluid is poured into the mixing vessel (Pfaudler) and then flows through the pump. The capacity of the system--including the heat exchangers, the test section, and the mixing unit--is about 25 gal [0.095 m3]. A high-accuracy, oval gear flowmeter was used for flow rate measurement. The meter was used only intermittently because it is a high- shear device that was originally intended to handle oil-base systems. A low-shear magnetic flowmeter has been added to the loop. The magnetic flowmeter shears the test fluids much less than the gear meter and can thus be left on continuously when testing shear-sensitive fracturing fluids. A differential pressure transducer measures pressure drop over the 20-ft-long [6.1-m], 0.957-in.-ID [2.43-cm] test section. The system is heated with a hot oil heater. An in-line, variable-shear-rate cup and bob viscometer allows continuous measurement of apparent viscosity at test temperature and pressure. It also-permits the running of rheograms to measure the flow pressure. It also-permits the running of rheograms to measure the flow parameters of the test fluid at any time during a test. parameters of the test fluid at any time during a test. A remote indication panel provides displays of flow rate, pressure drop, temperatures, shear stress, and shear rate. These values also are recorded on paper and magnetic tapes. A detailed description of the equipment, including recent improvements, is given in the Appendix. The improvements include the magnetic flowmeter mentioned previously, an automated data collection and reduction system, and a smaller pump. SPEJ p. 249


1967 ◽  
Vol 40 (5) ◽  
pp. 1483-1491
Author(s):  
Yoshio Ito

Abstract Nonnewtonian flow of poly(dimethyl siloxanes) of various molecular weights has been studied with a short capillary viscosimeter. The experiment covered a wide range of shear rate, from 10−1 to 3×106sec−1. Results were as follows: (1) Flow behavior of the sample changes with the degree of polymerization. For siloxanes with degrees of polymerization less than 1.55×102, flow of the fluid is newtonian throughout the whole range of shear rates; for siloxanes with degrees of polymerization from 3.22×102 to 2.63×103, flow is nonnewtonian at moderate shear rates; it again becomes newtonian at high shear rates. With degrees of polymerization more than 3.31×103, the spiral flow rises to a high shear rate. (2) Plow behavior of the samples is expressed by modifying Shishido's equation proposed for nonnewtonian polymer solutions. (3) When the observed flow curve contains its inflection point, the upper newtonian viscosity can be estimated by a new method proposed here. (4) The relations among the end correction of capillary, the pressure loss, and the shear stress proposed by Shishido for polymer solutions are applicable to poly(dimethy! siloxane) also.


2015 ◽  
Vol 47 ◽  
pp. 102-108 ◽  
Author(s):  
Prateek Sharma ◽  
Tzvetelin T. Dessev ◽  
Peter A. Munro ◽  
Peter G. Wiles ◽  
Graeme Gillies ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document