scholarly journals Stability Indicating Assay Method For The Quantitative Determination Of Olaparib In Bulk And Pharmaceutical Dosage Form

2021 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
ANTIMA CHAUDHARY ◽  
Rajiv Tonk ◽  
Pankaj Dagur ◽  
Suddhasattya Dey ◽  
Manik Ghosh
2012 ◽  
Vol 18 (1) ◽  
pp. 95-101 ◽  
Author(s):  
P.S. Jain ◽  
H.N. Jivani ◽  
R.N. Khatal ◽  
S.J. Surana

A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for quantitative determination of ciprofibrate in bulk drugs and in pharmaceutical dosage form in the presence of degradation products. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using an Ace5-C18 (250?4.6 mm, 5 ?m) advance chromatography column, and methanol and water (90:10 v/v) as a mobile phase. The detection was carried out at a wavelength of 232 nm. The ciprofibrate was subjected to stress conditions of hydrolysis (acid, base), oxidation, photolysis and thermal degradation. Degradation was observed for ciprofibrate in base, in acid and in 30% H2O2. The drug was found to be stable in the other stress conditions attempted. The degradation products were well resolved from the main peak. The percentage recovery of ciprofibrate was from (98.65 to 100.01%) in the pharmaceutical dosage form. The developed method was validated with respect to linearity, accuracy (recovery), precision, system suitability, specificity and robustness. The forced degradation studies prove the stability indicating power of the method.


2013 ◽  
Vol 96 (4) ◽  
pp. 751-757 ◽  
Author(s):  
Mehmet Gumustas ◽  
Sibel A Ozkan

Abstract A stability-indicating RP-LC assay method was developed for the simultaneous determination of the cardiovascular drugs amlodipine and perindopril in the presence of degradation products generated from forced decomposition studies. The developed method is applicable for the determination of related substances in bulk drugs and simultaneous assay in a tablet pharmaceutical dosage form. Separation of the drugs and their degradation products was obtained using an RP Waters Spherisorb ODS1 column (250 × 4.6 mm id, 5 μm particle size) with the mobile phase acetonitrile–water (30 + 70, v/v) containing 15 mM phosphoric acid. The pH of the mobile phase was adjusted to 5.0. A flow rate of 1.2 mL/min was used for the separations, with detection at 215 nm. The chromatographic separation was performed at a column temperature of 45°C. Atenolol was chosen as the internal standard. Amlodipine and perindopril were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. Degradation studies showed that both compounds were degraded under these stress conditions. The method was found to be stability-indicating and can be used for the routine analysis of amlodipine and perindopril in the studied combined tablet dosage form.


Il Farmaco ◽  
2005 ◽  
Vol 60 (4) ◽  
pp. 351-360 ◽  
Author(s):  
Neeraj Kaul ◽  
Himani Agrawal ◽  
Bharat Patil ◽  
Abhijit Kakad ◽  
S.R. Dhaneshwar

Author(s):  
K. Srinivasa Rao ◽  
Keshar N K ◽  
N Jena ◽  
M.E.B Rao ◽  
A K Patnaik

A stability-indicating LC assay method was developed for the quantitative determination of fenofibrate (FFB) in pharmaceutical dosage form in the presence of its degradation products and kinetic determinations were evaluated in acidic, alkaline and peroxide degradation conditions. Chromatographic separation was achieved by use of Zorbax C18 column (250 × 4.0 mm, 5 μm). The mobile phase was established by mixing phosphate buffer (pH adjusted 3 with phosphoric acid) and acetonitrile (30:70 v/v). FFB degraded in acidic, alkaline and hydrogen peroxide conditions, while it was more stable in thermal and photolytic conditions. The described method was linear over a range of 1.0-500 μg/ml for determination of FFB (r= 0.9999). The precision was demonstrated by relative standard deviation (RSD) of intra-day (RSD= 0.56– 0.91) and inter-day studies (RSD= 1.47). The mean recovery was found to be 100.01%. The acid and alkaline degradations of FFB in 1M HCl and 1M NaOH solutions showed an apparent zero-order kinetics with rate constants 0.0736 and 0.0698  min−1 respectively and the peroxide degradation with 5% H2O2 demonstrated an apparent first-order kinetics with rate constant k = 0.0202 per min. The t1/2, t90   values are also determined for all the kinetic studies. The developed method was found to be simple, specific, robust, linear, precise, and accurate for the determination of FFB in pharmaceutical formulations.  


Author(s):  
Sumithra M

Objective: The objective of the study is simple, sensitive; eco-friendly reverse phase chromatographic method has been developed and validated for the quantitative determination of ofloxacin in bulk and marketed formulation. Method: The developed method was done using Hypersil silica C18 (250 mm × 4.6 mm, 5 μ particle size) as column and the mobile phase is containing water and methanol in the ratio of (10:90) vol/vol. The mobile phase pass at 1 ml/min flow rate and the eluted solution is measured at 270 nm using a PDA detector. Results: The assay method is linear from the concentration range of 5–30 μg/ml. The corelation coefficient is 0.9998. The mean percentage recovery for the developed method is found to be in the range of 98.4–100.6%. The developed method complies robustness studies. Conclusion: The validation of the developed method was done by as per the ICH guidelines. It obeys the linearity, accuracy, precision, and robustness studies. Validation parameters are within the limitations. The results of the developed process indicated the reverse phase chromatographic method is simple, accurate as well as precise, rapid and eco-friendly method for routine analysis of ofloxacin in bulk and its pharmaceutical dosage form.


2019 ◽  
Vol 58 (3) ◽  
pp. 251-261
Author(s):  
Hala E Zaazaa ◽  
Rasha Abdel-Ghany ◽  
M Abdelkawy ◽  
Mahmoud Sayed

Abstract Two robust and selective stability-indicating chromatographic methods were developed and validated for the determination of metolazone in drug substance and pharmaceutical dosage form in the presence of its degradation products. The HPLC method employed a Kromasil C18 (250 × 4.6,5 μm) column and a mobile phase of acetonitrile: 0.2% orthophosphoric acid (32:68 v/v) at a flow rate 2 mL/min and detection at 238 nm. The separation was performed in HPLC isocratic mode. The robustness of the suggested method was assessed using the Plackett–Burman design, parameters affecting system suitability were established and non-significant intervals for the significant parameters were considered. The HPTLC method employed Nano-SIL-20 UV254 HPTLC plates as adsorbent, ethyl acetate: toluene: acetic acid solution (4:4:0.5, v/v/v), as a developing solvent system and densitometric detection at 238 nm. Metolazone was exposed to different stress conditions, including acid and alkaline hydrolysis and oxidative and photolytic degradation. The main degradation products obtained have been characterized and interpreted based on LC-MS. The linearity of the suggested methods was proved in the concentration range of 20–75 μg/mL for the HPLC method and 100–900 ng/spot for the HPTLC method. The suggested methods were validated according to international conference on harmonization guidelines. These methods were successfully dedicated for the estimation of metolazone in drug substance and pharmaceutical dosage form in the presence of its degradation products. The results of the suggested methods were evaluated and compared statistically with results obtained by an official method without finding any significant difference.


Sign in / Sign up

Export Citation Format

Share Document