scholarly journals Study of lifetime of Platinum Modified Metal Oxides Electrodes

2020 ◽  
Vol 14 (4) ◽  
pp. 1479-1488
Author(s):  
Lemeyonouin Aliou Guillaume Pohan ◽  
Ollo Kambiré ◽  
Mohamed Berté ◽  
Lassiné Ouattara

Pt, IrO2, RuO2, Pt-IrO2 and Pt-RuO2 electrodes have been shown to be effective in their application in various fields. However, it is necessary to study their long-term stability. So, our objective is to prepare them and study their lifetime using intensiostatic measurement. Then they were prepared at 400 °C on titanium plates used as a substrate. Physical measurements (scanning electron microscopy) of these anodes revealed that their surface are rough and porous structures. Lifetime study was carried out in H2SO4 9 N and under a current density of 410 mA /cm2. The long-term stability of Pt improved when coupled to IrO2 in contrast to RuO2. From this study, the performance of the electrode was found to increase in the order: RuO2 < Pt-RuO2 < Pt < Pt-IrO2 < IrO2. For RuO2 and IrO2 pure electrodes, the deactivation would be due to the dissolution of precursors deposited on the titanium. For the Pt pure electrode, deactivation would be due to the detachment of platinum coating. The deactivation of the Pt-IrO2 and Pt-RuO2 electrode would be due, on the one hand to the platinum detachment from IrO2 or RuO2 and on the other hand to the metal oxides (IrO2 or RuO2) dissolution.Keywords: Electrodes, platinum, metal oxides, lifetime.

2021 ◽  
Author(s):  
Ameya Manoj Tandel ◽  
Wenji Guo ◽  
Kelly Bye ◽  
Liang Huang ◽  
Michele Galizia ◽  
...  

As interest for membrane-based organic solvent separation increases, membrane materials exhibiting high permeance, high selectivity, and long-term stability against solvents are sought. Membrane technology has experienced tremendous progress by integrating...


2020 ◽  
Author(s):  
Benjamin Fores ◽  
Arnaud Watlet ◽  
Michel Van Camp ◽  
Olivier Francis

&lt;p&gt;Spring-based gravimeters are light and easy to install, with a precision around 5 &amp;#956;Gal/&amp;#8730;Hz. However, they are still not used for long-term gravity monitoring. The main reason for that is the non-linear drift of those instruments, which is very difficult to correct without removing geophysical signals. We will show that when the tilt is actively controlled, a gPhone spring-based gravimeter shows a quasi-linear drift and can reach a long-term stability at the &amp;#181;Gal level.&lt;/p&gt;&lt;p&gt;This allows experiments such as the one in the Rochefort Cave Laboratory (Belgium). Thanks to the size of the gPhone and its low facility requirements, a monitoring from inside a cave was possible. Coupled with another gravity monitoring at the surface, it reveals new information on the local hydrology of this karstic site.&lt;/p&gt;


Sign in / Sign up

Export Citation Format

Share Document