Polymerase Chain Reaction–Mediated Characterization of Molds Belonging to the Aspergillus flavus Group and Detection of Aspergillus parasiticus in Peanut Kernels by a Multiplex Polymerase Chain Reaction

2002 ◽  
Vol 65 (5) ◽  
pp. 840-844 ◽  
Author(s):  
RUEY-SHYANG CHEN ◽  
JWU-GUH TSAY ◽  
YU-FEN HUANG ◽  
ROBIN Y.-Y. CHIOU

The Aspergillus flavus group covers species of A. flavus and Aspergillus parasiticus as aflatoxin producers and Aspergillus oryzae and Aspergillus sojae as koji molds. Genetic similarity among these species is high, and aflatoxin production of a culture may be affected by cultivation conditions and substrate composition. Therefore, a polymerase chain reaction (PCR)-mediated method of detecting the aflatoxin-synthesizing genes to indicate the degree of risk a genotype has of being a phenotypic producer was demonstrated. In this study, 19 strains of the A. flavus group, including A. flavus, A. parasiticus, A. oryzae, A. sojae, and one Aspergillus niger, were subjected to PCR testing in an attempt to detect four genes, encoding for norsolorinic acid reductase (nor-1), versicolorin A dehydrogenase (ver-1), sterigmatocystin O-methyltransferase (omt-1), and a regulatory protein (apa-2), involved in aflatoxin biosynthesis. Concurrently, the strains were cultivated in yeast-malt (YM) broth for aflatoxin detection. Fifteen strains were shown to possess the four target DNA fragments. With regard to aflatoxi-genicity, all seven aflatoxigenic strains possessed the four DNA fragments, and five strains bearing less than the four DNA fragments did not produce aflatoxin. When peanut kernels were artificially contaminated with A. parasiticus and A. niger for 7 days, the contaminant DNA was extractable from a piece of cotyledon (ca. 100 mg), and when subjected to multiplex PCR testing using the four pairs of primers coding for the above genes, they were successfully detected. The target DNA fragments were detected in the kernels infected with A. parasiticus, and none was detected in the sound (uninoculated) kernels or in the kernels infected with A. niger.

2006 ◽  
Vol 52 (5) ◽  
pp. 451-461 ◽  
Author(s):  
S S Hynes ◽  
O Chaudhry ◽  
M A Providenti ◽  
M L Smith

The ability to rapidly identify and quantify a microbial strain in a complex environmental sample has widespread applications in ecology, epidemiology, and industry. In this study, we describe a rapid method to obtain functionally specific genetic markers that can be used in conjunction with standard or real-time polymerase chain reaction (PCR) to determine the abundance of target fungal strains in selected environmental samples. The method involves sequencing of randomly cloned AFLP (amplified fragment length polymorphism) products from the target organism and the design of PCR primers internal to the AFLP fragments. The strain-specific markers were used to determine the fate of three industrially relevant fungi, Aspergillus niger, Aspergillus oryzae, and Chaetomium globosum, during a 4 month soil microcosm experiment. The persistence of each of the three fungal strains inoculated separately into intact soil microcosms was determined by PCR analyses of DNA directly extracted from soil. Presence and absence data based on standard PCR and quantification of the target DNA by real-time PCR showed that all three strains declined after inoculation (~14-, 32-, and 4-fold for A. niger, A. oryzae, and C. globosum, respectively) but remained detectable at the end of the experiment, suggesting that these strains would survive for extended periods if released into nature.Key words: Canada domestic substances list (DSL), Canadian Environmental Protection Act (CEPA), genetically modified organisms (GMO), quantitative polymerase chain reaction (qPCR).


2010 ◽  
Vol 100 (4) ◽  
pp. 337-344 ◽  
Author(s):  
M. Catal ◽  
G. C. Adams ◽  
D. W. Fulbright

A quantitative polymerase chain reaction assay was developed that could detect DNA of Rhabdocline pseudotsugae and R. oblonga among DNA of Douglas fir needles to a limit as low as three copies of target DNA. Differential infection rates of two varieties (seed sources) of Douglas fir interplanted in a field were studied in relation to staggered bud breaks. Infection of Douglas fir var. San Isabel corresponded to ascospore release times for Rhabdocline spp., whereas infection of var. Shuswap Lake did not occur throughout the spore release period during 2 years of study, despite abundant inoculum and adequate moisture during bud break. Rhabdocline spp. DNA was never detected in Shuswap Lake and disease symptoms were not observed in any year. We provide evidence that Shuswap Lake is resistant and probably immune to Rhabdocline spp. infection and Rhabdocline needlecast under Michigan conditions.


1998 ◽  
Vol 6 (5) ◽  
pp. 224-229
Author(s):  
C. H. Livengood III ◽  
K. A. Boggess ◽  
J. W. Wrenn ◽  
A. P. Murtha

Objectives:To examine the accuracy of a commercial polymerase chain reaction (PCR) test (Amplicor CTR, Roche Diagnostic Systems, Branchburg NJ) for identification of endocervical chlamydial infections through both laboratory evaluation and among a diverse teaching hospital patient population.Methods:Testing of reliable threshold inocula and reproducibility were carried out using laboratory stock organisms. Paired endocervical samples from patients with a wide range of indications were tested by PCR and an established culture procedure, and discrepant pairs were further analyzed to determine true results.Results:Laboratory evaluation suggested that one copy of target DNA from a viable organism consistently yielded a positive result, and test reproducibility was very good, with an overall coefficient of variation of 15%. Compared to true results in 1,588 paired clinical samples from 1,489 women with a 10% prevalence of infection, the PCR test and culture yielded respective sensitivities of 87.4% and 78.0%, and negative predictive values of 98.6% and 97.6%. Specificity and positive predictive value for both tests were 100%. Cost per specimen was nearly identical at $18.84 and $18.88 respectively. Polymerase inhibitors and organisms lacking target DNA were not found in false-negative PCR samples.Conclusion:This commercial PCR test is accurate, cost-competitive, and much faster than culture for diagnosis of endocervical chlamydia infections in our population of intermediate prevalence of chlamydial infection.


2020 ◽  
Vol 58 (4) ◽  
pp. 527-532 ◽  
Author(s):  
Jee-Soo Lee ◽  
Miyoung Kim ◽  
Moon-Woo Seong ◽  
Han-Sung Kim ◽  
Young Kyung Lee ◽  
...  

AbstractBackgroundChoosing the specimen type is the first step of the pre-analytical process. Previous reports suggested plasma as the optimal specimen for circulating tumor DNA (ctDNA) analysis. However, head-to-head comparisons between plasma and serum using platforms with high analytical sensitivity, such as droplet digital polymerase chain reaction (ddPCR), are limited, and several recent studies have supported the clinical utility of serum-derived ctDNA. This study aimed to compare the DNA profiles isolated from plasma and serum, characterize the effects of the differences between specimens on ctDNA measurement, and determine the major contributors to these differences.MethodsWe isolated cell-free DNA (cfDNA) from 119 matched plasma/serum samples from cancer patients and analyzed the cfDNA profiles by DNA fragment sizing. We then assessed KRAS mutations in ctDNA from matched plasma/serum using ddPCR.ResultsThe amount of large DNA fragments was increased in serum, whereas that of cfDNA fragments (<800 bp) was similar in both specimens. ctDNA was less frequently detected in serum, and the KRAS-mutated fraction in serum was significantly lower than that in plasma. The differences in ctDNA fractions between the two specimen types correlated well with the amount of large DNA fragments and white blood cell and neutrophil counts.ConclusionsOur results provided detailed insights into the differences between plasma and serum using DNA fragment sizing and ddPCR, potentially contributing to ctDNA analysis standardization. Our study also suggested that using plasma minimizes the dilution of tumor-derived DNA and optimizes the sensitivity of ctDNA analysis. So, plasma should be the preferred specimen type.


1996 ◽  
Vol 241 (1) ◽  
pp. 136-139 ◽  
Author(s):  
Masayoshi Iizuka ◽  
Yuki Sugiyama ◽  
Shigeru Iida ◽  
Takao Sekiya

Sign in / Sign up

Export Citation Format

Share Document