Development of a Macrophage Cell Culture Method To Isolate and Enrich Francisella tularensis from Food Matrices for Subsequent Detection by Real-Time PCR

2009 ◽  
Vol 72 (6) ◽  
pp. 1156-1164 ◽  
Author(s):  
J. B. DAY ◽  
R. C. WHITING

Francisella tularensis is a gram-negative bacterium that can cause gastrointestinal or oropharyngeal tularemia in humans from ingestion of contaminated food or water. Despite the potential for accidental or intentional contamination of foods with F. tularensis, there are no techniques currently available to detect this organism in specific food matrices. In this study, a macrophage cell culture system is combined with real-time PCR to identify F. tularensis in food matrices. The method utilizes a mouse macrophage cell line (RAW 264.7) as host for the isolation and intracellular replication of F. tularensis. Exposure of macrophages to F. tularensis–contaminated food matrices results in uptake and intracellular replication of the bacteria, which can be subsequently detected by real-time PCR analysis of the DNA released from infected macrophage cell lysates. Macrophage monolayers were exposed to infant formula, liquid egg whites, and lettuce contaminated with varying quantities of F. tularensis. As few as 10 CFU/ml (or CFU per gram) F. tularensis was detected in infant formula and lettuce after 5 h postinfection. As few as 10 CFU/ml F. tularensis was detected in liquid egg whites after 18 h postinfection. Intracellular F. tularensis could also be isolated on Mueller-Hinton medium from lysates of macrophages infected with the bacteria in infant formula, liquid egg whites, and lettuce for subsequent confirmatory identification. This method is the first to successfully identify F. tularensis from select food matrices.

2009 ◽  
Vol 75 (16) ◽  
pp. 5321-5327 ◽  
Author(s):  
J. B. Day ◽  
U. Basavanna ◽  
S. K. Sharma

ABSTRACT Salmonella enterica serotype Enteritidis is a major cause of nontyphoidal salmonellosis from ingestion of contaminated raw or undercooked shell eggs. Current techniques used to identify Salmonella serotype Enteritidis in eggs are extremely laborious and time-consuming. In this study, a novel eukaryotic cell culture system was combined with real-time PCR analysis to rapidly identify Salmonella serotype Enteritidis in raw shell eggs. The system was compared to the standard microbiological method of the International Organization for Standardization (Anonymous, Microbiology of food and animal feeding stuffs—horizontal method for the detection of Salmonella, 2002). The novel technique utilizes a mouse macrophage cell line (RAW 264.7) as the host for the isolation and intracellular replication of Salmonella serotype Enteritidis. Exposure of macrophages to Salmonella serotype Enteritidis-contaminated eggs results in uptake and intracellular replication of the bacterium, which can subsequently be detected by real-time PCR analysis of the DNA released after disruption of infected macrophages. Macrophage monolayers were exposed to eggs contaminated with various quantities of Salmonella serotype Enteritidis. As few as 10 CFU/ml was detected in cell lysates from infected macrophages after 10 h by real-time PCR using primer and probe sets specific for DNA segments located on the Salmonella serotype Enteritidis genes sefA and orgC. Salmonella serotype Enteritidis could also be distinguished from other non-serogroup D Salmonella serotypes by using the sefA- and orgC-specific primer and probe sets. Confirmatory identification of Salmonella serotype Enteritidis in eggs was also achieved by isolation of intracellular bacteria from lysates of infected macrophages on xylose lysine deoxycholate medium. This method identifies Salmonella serotype Enteritidis from eggs in less than 10 h compared to the more than 5 days required for the standard reference microbiological method of the International Organization for Standardization (Microbiology of food and animal feeding stuffs—horizontal method for the detection of Salmonella, 2002).


2005 ◽  
Vol 71 (7) ◽  
pp. 3433-3441 ◽  
Author(s):  
M. A. Yáñez ◽  
C. Carrasco-Serrano ◽  
V. M. Barberá ◽  
V. Catalán

ABSTRACT A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.


2008 ◽  
Vol 10 (3) ◽  
pp. 362 ◽  
Author(s):  
Ricela Sellek ◽  
Oscar Jimenez ◽  
Carmen Aizpurua ◽  
Begoña Fernandez-Frutos ◽  
Patricia De Leon ◽  
...  

2006 ◽  
Vol 4 (s1) ◽  
pp. 82-82
Author(s):  
K. Floros ◽  
H. Thomadaki ◽  
S. Pavlovic ◽  
M. Talieri ◽  
M. Colovic ◽  
...  

2021 ◽  
Vol 70 (9) ◽  
Author(s):  
Berta Fidalgo ◽  
Elisa Rubio ◽  
Victor Pastor ◽  
Marta Parera ◽  
Clara Ballesté-Delpierre ◽  
...  

Introduction. The identification of enteropathogens is critical for the clinical management of patients with suspected gastrointestinal infection. The FLOW multiplex PCR system (FMPS) is a semi-automated platform (FLOW System, Roche) for multiplex real-time PCR analysis. Hypothesis/Gap Statement. FMPS has greater sensitivity for the detection of enteric pathogens than standard methods such as culture, biochemical identification, immunochromatography or microscopic examination. Aim.The diagnostic performance of the FMPS was evaluated and compared to that of traditional microbiological procedures. Methodology. A total of 10 659 samples were collected and analysed over a period of 7 years. From 2013 to 2018 (every July to September), samples were processed using standard microbiological culture methods. In 2019, the FMPS was implemented using real-time PCR to detect the following enteropathogens: Shigella spp., Salmonella spp., Campylobacter spp., Giardia intestinalis, Entamoeba histolytica, Blastocystis hominis, Cryptosporidum spp., Dientamoeba fragilis, adenovirus, norovirus and rotavirus. Standard microbiological culture methods (2013–2018) included stool culture, microscopy and immunochromatography. Results. A total of 1078 stool samples were analysed prospectively using the FMPS from July to September (2019): bacterial, parasitic and viral pathogens were identified in 15.3, 9.71 and 5.29 % of cases, respectively. During the same period of 6 years (2013–2018), the proportion of positive identifications using standard microbiological methods from 2013 to 2018 was significantly lower. A major significant recovery improvement was observed for all bacteria species tested: Shigella spp./enteroinvasive Escherichia coli (EIEC) (P <0.05), Salmonella spp. (P <0.05) and Campylobacter spp. (P <0.05). Marked differences were also observed for the parasites G. intestinalis, Cryptosporidium spp. and D. fragilis. Conclusion. These results support the value of multiplex real-time PCR analysis for the detection of enteric pathogens in laboratory diagnosis with outstanding performance in identifying labile micro-organisms. The identification of unsuspected micro-organisms for less specific clinical presentations may also impact on clinical practice and help optimize patient management.


2017 ◽  
Vol 16 (34) ◽  
pp. 1791-1799 ◽  
Author(s):  
Meryem Idrissi Azzouzi Lalla ◽  
Senouci Samira ◽  
El Qazoui Maria ◽  
Oumzil Hicham ◽  
Naciri Mariam
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document