scholarly journals Determination of crinamidine in dietary supplements by GC-MS/MS

Author(s):  
Lien Le Thi ◽  
Anh Bach Thuy ◽  
Khanh Cao Cong ◽  
Ha Tran Nguyen ◽  
Hong Hao Le Thi ◽  
...  

The determination of crinamidine in dietary supplements content by mass spectrometry (GC-MS/MS) was developed and validated. The method was performed on the DB5MS column (30m x 0,25mm; 0,25 μm), in combination with the tandem mass spectrometry. The parameters of the method were evaluated for selectivity, calibration curve, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination 0.9970) within the concentration range of 5ppm-50ppm. The recovery at three concentrations were above 90,1%. The limit of detection (LOD) and limit of quantification (LOQ) of the methods were 3 and 10 mg/kg, respectively. All obtained results were acceptable according to the AOAC for dietary supplements. The method was applied to analyze 34 samples in Hanoi.

Molecules ◽  
2020 ◽  
Vol 25 (19) ◽  
pp. 4399
Author(s):  
Dasom Shin ◽  
Hui-Seung Kang ◽  
Hyungsoo Kim ◽  
Guiim Moon

In this work, liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated for screening and confirmation of 64 illicit compounds in dietary supplements. The target compounds were illegally used pharmaceutical drugs, prohibited compounds, and not authorized ingredients for different therapeutics (sexual enhancement, weight loss, muscular strengthening, and relaxing products). The validation procedure was performed to evaluate selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was >0.98 in the range of 0.5–200 µg L−1. The LOQs were in the range 1–10 µg kg−1 for all target compounds. The accuracy (expressed as recovery) was 78.5–114%. The precision (expressed as the relative standard deviation) was below 9.15%. The developed method was applied for the determination of illicit compounds in dietary supplements collected from websites. As a result, the total detection rate was 13.5% (27 samples detected in 200 samples). The concentrations of detected samples ranged from 0.51 to 226 mg g−1. The proposed methodology is suitable for monitoring the adulteration of illicit compounds in dietary supplements.


2002 ◽  
Vol 85 (4) ◽  
pp. 853-860 ◽  
Author(s):  
Anton Kaufmann ◽  
Sven Roth ◽  
Bianca Ryser ◽  
Mirjam Widmer ◽  
Dominik Guggisberg

Abstract A simple and rapid method was developed for the determination of 20 antibiotics (sulfonamides, tetracyclines, and flumequine) in honey by liquid chromatography tandem mass spectrometry. The proposed method is sensitive (limit of detection 0.5 to 10 ppb for the various antibiotics) and selective. A hydrolysis step ensures the liberation of sugar-bound sulfonamides. The approach has been used to analyze some 300 honey samples. A number of them were found to have exceeded the Swiss limit of 50 ppb.


2007 ◽  
Vol 90 (1) ◽  
pp. 343-348 ◽  
Author(s):  
Ross A Potter ◽  
B Garth Burns ◽  
Jeffrey M van de Riet ◽  
David H North ◽  
Rozina Darvesh

Abstract A simple, robust method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of 17 sulfonamides sulfanilamide (SNL), sulfacetamide (SAA), sulfaguanidine (SGD), sulfapyridine (SPY), sulfadiazine (SDZ), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethoxazole (SOZ), sulfamoxole (SXL), sulfisoxazole (SXZ), sulfamethizole (SML), sulfamethazine (SMZ), sulfamethoxypyridazine (SMP), sulfamonomethoxine (SMM), sulfachloropyridazine (SCP), sulfaquinoxaline (SQX), and sulfadimethoxine (SDM) and 2 potentiators ormetoprim (OMP) and trimethoprim (TMP) in fish tissue has been developed. The analytes were extracted from homogenized fish tissue with wateracetonitrile (50 + 50). The extract was clarified by centrifugation and a portion defatted with hexane. The analytes were partitioned into chloroform and evaporated to dryness. The redissolved residue was applied to a C18 reversed-phase column with a wateracetonitrile (0.1% acetic acid) gradient. All of the compounds were completely separated and detected in <10 min at 30°C using LC/MS/MS. Standard curves were linear over the range of 0.02 to 5 ng injected. The limit of detection varied from 0.1 ng/g for SMZ and OMP to 0.9 ng/g for SXL and SOZ. Recoveries varied from 100% for SDM, SOZ, and SQX and 85% for SMR, OMP, and TMP to approximately 30% for SAA. Relative standard deviations for repeat analysis varied from 4% for SMZ and SCP to 23% for SAA.


2008 ◽  
Vol 91 (5) ◽  
pp. 1095-1102 ◽  
Author(s):  
Robert Sheridan ◽  
Thomas King

Abstract A highly sensitive and selective method that requires minimal sample preparation was developed for the confirmation and quantitation of cyclamate in a variety of foods by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Sample preparation consisted of homogenization followed by extraction and dilution of cyclamate with water. HPLC separation was achieved using a bridged ethyl hybrid C18 high-pressure column with a mobile phase consisting of 0.15 acetic acid and methanol. Under electrospray ionization negative conditions, quantitation was achieved by monitoring the fragment m/z 79.7 while also collecting parent ion m/z 177.9. Two food matrixes, diet soda and jelly, were subjected to a validation procedure in order to evaluate the applicability of the method. The cyclamate limit of detection for both matrixes was determined to be 0.050 g/g with a limit of quantitation of 0.150 g/g. The correlation coefficient of the calibration curves was >0.9998 from 0.0005 to 0.100 g/mL. The method has been used for the determination of cyclamate in several foods and the results are presented.


2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
Dinesh S. Patel ◽  
Naveen Sharma ◽  
Mukesh C. Patel ◽  
Bhavin N. Patel ◽  
Pranav S. Shrivastav ◽  
...  

A reliable, rapid, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been proposed for the determination of rizatriptan in human plasma using sumatriptan as internal standard (IS). The analyte and IS were extracted from 300 μL human plasma via liquid-liquid extraction and the chromatography was achieved on Hypurity C18 (50 mm × 4.6 mm, 5 μm) column under isocratic conditions. Detection of rizatriptan and IS was done by tandem mass spectrometry, operating in positive ionization and multiple-reaction monitoring mode. The limit of detection and lower limit of quantitation of the method were 0.04 and 0.20 ng/mL, respectively, with a linear dynamic range of 0.20–60.0 ng/mL. The intrabatch and interbatch precision (% CV) was ≤8.4% while the mean extraction recovery was >78% across quality control levels. Bench top stability, freeze and thaw stability, processed sample stability, and long-term stability in plasma were evaluated at two quality control levels. It was successfully applied to a bioequivalence study of 10 mg rizatriptan orally disintegrating tablet formulation in 40 and 32 healthy Indian male subjects under fasting and fed conditions, respectively. The reproducibility in the measurement of study data was demonstrated by reanalysis of 254 incurred samples.


Sign in / Sign up

Export Citation Format

Share Document