scholarly journals Angle Measurement of the Papillary Projection in Unilocular-solid Adnexal Cysts as a Predictor of Malignancy: A Three-dimensional Ultrasound Study

Author(s):  
Federico Moreno ◽  
Juan Luis Alcázar ◽  
Nabil Manzour ◽  
Isabel Carriles ◽  
Daniel Sanin-Ramirez ◽  
...  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Phob Ganokroj ◽  
Nuchanun Sompornpanich ◽  
Pichitpol Kerdsomnuek ◽  
Bavornrat Vanadurongwan ◽  
Pisit Lertwanich

Abstract Background Measurement of hip rotation is a crucial clinical parameter for the identification of hip problems and the monitoring of symptoms. The objective of this study was to determine whether the use of two smartphone applications is valid and reliable for the measurement of hip rotation. Methods An experimental, cross-sectional study was undertaken to assess passive hip internal and external rotation in three positions by two examiners. The hip rotational angles were measured by a smartphone clinometer application in the sitting and prone positions, and by a smartphone compass application in the supine position; their results were compared with those of the standard, three-dimensional, motion analysis system. The validities and inter-rater and intra-rater reliabilities of the smartphone applications were evaluated. Results The study involved 24 participants. The validities were good to excellent for the internal rotation angles in all positions (ICC 0.81–0.94), good for the external rotation angles in the prone position (ICC 0.79), and fair for the sitting and supine positions (ICC 0.70–0.73). The measurement of the hip internal rotation in the supine position had the highest ICC value of 0.94 (0.91, 0.96). The two smartphone applications showed good-to-excellent intra-rater reliability, but good-to-excellent inter-rater reliability for only three of the six positions (two other positions had fair reliability, while one position demonstrated poor reliability). Conclusions The two smartphone applications have good-to-excellent validity and intra-rater reliability, but only fair-to-good inter-rater reliability for the measurement of the hip rotational angle. The most valid hip rotational position in this study was the supine IR angle measurement, while the lowest validity was the ER angle measurement in the sitting position. The smartphone application is one of the practical measurements in hip rotational angles. Trial registration Number 20181022003 at the Thai Clinical Trials Registry (http://www.clinicaltrials.in.th) which was retrospectively registered at 2018-10-18 15:30:29.


2006 ◽  
Vol 32 (6) ◽  
pp. 791-795 ◽  
Author(s):  
Chiung-Hsin Chang ◽  
Chen-Hsiang Yu ◽  
Huei-Chen Ko ◽  
Chi-Ling Chen ◽  
Fong-Ming Chang

2017 ◽  
Author(s):  
James A. Coller ◽  
Andrew Silver ◽  
Okey Nwogu ◽  
Benjamin S.H. Connell

The US Nav has developed a real-time multi-ship ship motion forecasting system which combines forecast wave conditions with ship motion simulations to produce a prediction of the relative motions between two ships operating in a skin-to-skin configuration. The system utilizes two different simulation methods for predicting ship motions: MotionSim and Reduced Order Model (ROM) based on AEGIR. MotionSim is a fast three-dimensional panel method that is used to estimate the Response Amplitude Operators (RAOs) necessary for multi-ship motion predictions. The ROM works to maximize the accuracy of high fidelity ship motion prediction methods while maintaining the computational speed required for real-time forecasting. A model scale experiment was performed in 2015 on two Navy ships conventionally moored together. The predicted relative ship motions from MotionSim and ROM were compared to the model data using three different metrics: RMS (root mean square) ratio, correlation coefficient, and average angle measurement (AAM).This paper provides an overview of the two methods for predicting the multi-ship motions, a description of the model test, challenges faced during testing, and a discussion on the methodology of the evaluation and the results of each code correlation.


2007 ◽  
Vol 46 (17) ◽  
pp. 3539 ◽  
Author(s):  
Lingfeng Yu ◽  
Giancarlo Pedrini ◽  
Wolfgang Osten ◽  
Myung K. Kim

2008 ◽  
Vol 32 (6) ◽  
pp. 755-761 ◽  
Author(s):  
D. Paladini ◽  
M. Vassallo ◽  
G. Sglavo ◽  
G. Pastore ◽  
C. Lapadula ◽  
...  

2013 ◽  
Vol 344 ◽  
pp. 93-98 ◽  
Author(s):  
Xin Ming Liu ◽  
Yao Yu Zhang ◽  
Xiao Yong Feng ◽  
Qian Xue Wang

In this paper, a novel method for hulls three-dimensional angle measurement is presented. For the measurement of the transverse twist angle, a method based on moiré fringe is proposed, for the lengthways flexibility and course flexibility angle the conventional optical sensor method is applied. The principle of the measurement is discussed in detail. To verify the accuracy of the proposed method, both static and dynamic experiments are carried out. Results show that in the static states, the accuracy for them are smaller than 5'', in the dynamic states, the accuracy for them are smaller than 10''.


Sign in / Sign up

Export Citation Format

Share Document