scholarly journals Effect of Silanization on Push-out Bond Strength of H2O2-etched Fiber Posts Using Various Resin Cements: An In Vitro Study

2019 ◽  
Vol 4 (1) ◽  
pp. 27-32
Author(s):  
Chandrakanth Majeti ◽  
Chandrasekhar Veeramachineni ◽  
Ravichandra Ravi
2013 ◽  
Vol 8 (3) ◽  
pp. 296-305 ◽  
Author(s):  
Bogdan Baldea ◽  
Gabriel Furtos ◽  
Mark Antal ◽  
Katalin Nagy ◽  
Dragos Popescu ◽  
...  

2021 ◽  
Vol 11 (14) ◽  
pp. 6349
Author(s):  
Regina María Del Río Carrillo ◽  
Pedro Molinero-Mourelle ◽  
Vicente Vera ◽  
Pablo Romero Villaba ◽  
Elizabeth Casañas ◽  
...  

To evaluate the bond strength of different universal adhesives on deciduous tooth dentineand their relationship with the composition and potential of hydrogen (pH). Methods: An in vitromicro push-out test on 150 samples (n = 50) per group per adhesive, namely, Adhese Universal(ADH; Ivoclar Vivadent), Futurabond U (FUT; Voco GmbH) (Test), and Scotchbond Universal withpre-conditioning (SCO; 3M) (Control), to record bond strength (BS) and type of adhesive failure.Results: The results of the different adhesives (megapascals (MPa)) varied, showing no statisticalsignificance. The corresponding averages are in MPa: ADH, 13.66 2.81; FUT, 14.48 2.88; SCO,14.98 3.96. Additionally, the frequency of type of failure was as follows: mixed (60.7%), adhesive(27.3%), and cohesive (12%). Conclusions: SCO, with a pH of 2.7, showed greater resistance tofracture, while FUT, with a pH of 2.3 and no pre-conditioning, approached the same values, being aone-step adhesive. No relationship was found between failure and type of adhesive.


2018 ◽  
Vol 6 (9) ◽  
pp. 1707-1711
Author(s):  
Rami M. Atia ◽  
Nada Omar ◽  
Haidy Nabil ◽  
Yousra Aly

OBJECTIVE: The aim of this in vitro study was to assess the effect of obturation technique and cementation timings on the bonding of fibre-reinforced posts to the root canal walls. METHODS: Twenty extracted teeth were randomly allocated to two groups according to the obturation technique and cementation timing. Central incisors with single canals were used after being decoronated. Every extracted tooth of the {vertical compaction group} (VC) group (n = 10) had been obturated using the {E & Q plus obturation system} with posts cemented in the same day; The other (CO) conventional group (n = 10) teeth were obturated using the conventional lateral compaction technique and posts cemented after one week. “SF“ Fiber posts were used after bonding and cementation using Rely X ARC resin cement with all the endodontically treated teeth. The push-out test was performed in a universal testing machine. Data were analysed by 2 way analysis of variance with Statistical significance was set to 0.05. RESULTS: Heat softened gutta percha group showed more push out the bond strength of the bonded posts than the conventional obturation group (p < 0.05). In the middle region, there was no statistical significance between the two groups while there was significance in the coronal and apical thirds. CONCLUSION: The vertical compaction technique and early cementation improved the bond strength of the resin posts in comparison to the conventional obturation technique with late cementation.


2013 ◽  
Vol 38 (5) ◽  
pp. 555-564 ◽  
Author(s):  
GM Gomes ◽  
OMM Gomes ◽  
A Reis ◽  
JC Gomes ◽  
AD Loguercio ◽  
...  

SUMMARY Objectives To evaluate the influence of operator experience (dentist vs student) and cementation system (Adper Scotchbond Multi-Purpose [SBMP] + RelyX ARC [1]; Adper Single Bond 2 [SB] + RelyX ARC [2] and RelyX U100 [3]) on the push-out bond strength (BS) of fiber post to radicular dentin. Materials and Methods The roots of 48 extracted human maxillary central incisors were prepared and divided into six groups (n=8), according to combination of the above factors. Glass fiber posts were cemented in accordance with the instructions of the manufacturer of each cementation system. After water storage at 37°C for one week, the roots were cross-sectioned into six 1-mm thick slices and the push-out test was performed (0.5 mm/min). Data were statistically analyzed by two-way analysis of variance and Tukey tests (α=0.05). The BS results obtained by dentist and student for each cementation system were compared using the Student t-test (α=0.05). Results Higher BS means were observed for the expert operators, irrespective of the cementation system used (p=0.006). RelyX U100 showed the highest bond strength, but it did not differ from SBMP + RelyX ARC. The Student t-test revealed that only RelyX U100 was not affected by the operator's experience. Conclusion Within the limitations of this in vitro study, it can be concluded that the self-adhesive cement RelyX U100 showed the highest bond strength to the root canal in the student's group, and its performance was not affected by the operator's experience.


2014 ◽  
Vol 50 ◽  
pp. 228-234 ◽  
Author(s):  
Thiago Henrique Scarabello Stape ◽  
Murilo de Sousa Menezes ◽  
Flávio Henrique Baggio Aguiar ◽  
Paulo Sérgio Quagliatto ◽  
Carlos José Soares ◽  
...  

2021 ◽  
Vol 24 (1) ◽  
pp. 41
Author(s):  
Roopadevi Garlapati ◽  
KolluriMohana Chandra ◽  
PraveenKumar Gali ◽  
Bolla Nagesh ◽  
Sayesh Vemuri ◽  
...  

2019 ◽  
Vol 10 (4) ◽  
pp. 631
Author(s):  
Nimeshika Ramachandruni ◽  
MohammedKhwaja Moinuddin ◽  
LKarthik Prasad ◽  
Shekar Kamishetty ◽  
RaviChandra Cherkupalli

Sign in / Sign up

Export Citation Format

Share Document