scholarly journals Quali-quantitative characterization of biogas with the temporal behavior of organic load on wastewater treatment plant with upflow anaerobic sludge blanket reactors through measurement in full‑scale systems

2021 ◽  
Vol 56 (4) ◽  
pp. 621-629
Author(s):  
Orlando Antonio Duarte Hernandez ◽  
Ana Caroline Paula ◽  
Gustavo Rafael Collere Possetti ◽  
Mauricio Pereira Cantão ◽  
Miguel Mansur Aisse

This study aims to present the time behavior of wastewater flow parameters, organic matter, biogas flow, biogas composition, and its relations, measured through online sensors, in a municipal wastewater treatment plant (WWTP) operating full-scale upflow anaerobic sludge blanket (UASB) reactors, installed in the south of Brazil. WWTP has online measurement devices to evaluate some physicochemical variables of the sewage and the biogas. The COD analyzer (UV– Vis probe), ultrasonic flow meter, biogas flow meter, and biogas composition analyzer were the equipment used. The monitoring occurred for two time periods each of 72 h and one time period for 48 h in the year 2018. Data were checked with descriptive statistics, data independence was checked through the autocorrelation Box– Ljung test, normality behavior was checked with several tests (Shapiro– Wilk, Kolmogorov–Smirnov, Lilliefors, Anderson–Darling, D’Agostino K2, and Chen–Shapiro), and Spearman’s correlation coefficient was used to evaluate the correlations among the parameters. The mean sewage flow was 345 ± 120 L.s-1; removed organic load was, in average, 48%; biogas quality values were 82.32% ± 3.62% v/v (CH4), 2.66% ± 1.19% v/v (CO2), and 3453 ± 1268 ppm (H2S); and the production per capita obtained was 4.51 ± 1.65 NL.hab-1.d-1. It was estimated an electric power generation of 3118.6 kWh.d-1, which is equivalent to an installed power of 130 KW. The behavior of removed organic load and biogas flow (Nm3.h-1), produced in the treatment plant, showed variable, periodic, and nonstationary time behavior.  

2019 ◽  
Vol 14 (4) ◽  
pp. 908-920 ◽  
Author(s):  
Oliver Saavedra ◽  
Ramiro Escalera ◽  
Gustavo Heredia ◽  
Renato Montoya ◽  
Ivette Echeverría ◽  
...  

Abstract This study aims to determine the seasonal variability in the performance of a medium size population wastewater treatment plant (WWTP) in Bolivia. The semi-arid area where the WWTP is located is characterized as agricultural land, with an annual rainfall of 500 mm and a mean temperature of 17 °C. The WWTP is built up of five modules, each one comprising two treatment trains composed of an upflow anaerobic sludge blanket (UASB) reactor and horizontal gravel filter. The performance of the full process has been determined based on water quantity and quality. Seven monitoring campaigns of chemical and physical wastewater characteristics were performed from March to December 2017. The measured effluent showed average removal efficiencies of 83 ± 8% and 37 ± 60% for total chemical oxygen demand (COD) and total suspended solids (TSS), respectively. The treatment system has proven to be efficient to remove organic matter and TSS, despite the occurrence of high COD and total solids (TS) influent concentrations, the accumulation of solids at all the processes and the variability of flow and temperature inside the UASB reactors. In order to improve further this efficiency, it is recommended to implement a primary sedimentation unit as a pretreatment for the UASB system that would help to homogenize both the flow and the quality of the influent.


Author(s):  
Thaís Andrade de Sampaio Lopes ◽  
Luciano Matos Queiroz ◽  
Asher Kiperstok

Life Cycle Assessment (LCA) was applied to estimate and analyze the environmental impacts from the construction and operation phases of a full-scale wastewater treatment plant (WWTP) located in the municipality of Lauro de Freitas, Bahia, Brazil. The WWTP process consists of the association of an Upflow Anaerobic Sludge Blanket (UASB) reactor followed by four constructed wetlands (CWL) and a disinfection step. The functional unit was defined as one cubic meter of treated effluent during the useful life of this WWTP (20 years). The LCA was carried out using SimaPro® software and the Centre of Environmental Science (CML) assessment method. The environmental impacts during construction phase were mainly from the wooden forms for concrete and the use of reinforcing steel. During the operation phase, the chlorine used as effluent disinfectant caused the greatest impacts in the abiotic depletion and acidification categories. Macronutrient concentrations present in the treated effluent and the methane generated also caused significant environmental impacts during the WWTP’s useful life. The results obtained highlight the importance of the application of a methodology like LCA to assist in decision-making with regard to the implementation, construction and operation of a WWTP.


2015 ◽  
Vol 73 (2) ◽  
pp. 309-316 ◽  
Author(s):  
V. Del Nery ◽  
M. H. Z. Damianovic ◽  
R. B. Moura ◽  
E. Pozzi ◽  
E. C. Pires ◽  
...  

This paper assesses a wastewater treatment plant (WWTP) regarding the technology used, as well as organic matter and nutrient removal efficiencies aiming to optimize the treatment processes involved and wastewater reclamation. The WWTP consists of a dissolved air flotation (DAF) system, an upflow anaerobic sludge blanket (UASB) reactor, an aerated-facultative pond (AFP) and a chemical-DAF system. The removal efficiencies of chemical oxygen demand (COD) (97.9 ± 1.0%), biochemical oxygen demand (BOD) (98.6 ± 1.0%) and oil and grease (O&G) (91.1 ± 5.2%) at the WWTP, the nitrogen concentration of 17 ± 11 mgN-NH3 and phosphorus concentration of 1.34 ± 0.93 mgPO4−3/L in the final effluent indicate that the processes used are suitable to comply with discharge standards in water bodies. Nitrification and denitrification tests conducted using biomass collected at three AFP points indicated that nitrification and denitrification could take place in the pond.


2014 ◽  
Vol 69 (7) ◽  
pp. 1518-1525
Author(s):  
Laurence Damasceno de Oliveira ◽  
Amir Mohaghegh Motlagh ◽  
Ramesh Goel ◽  
Beatriz de Souza Missagia ◽  
Benício Alves de Abreu Filho ◽  
...  

In this study, a submerged aerated filter (SAF) using bottle caps as a support medium was evaluated. The system was fed with effluent from an upflow anaerobic sludge blanket system at ETE 2-South wastewater treatment plant, under different volumetric organic load rates (VOLRs). The population of a particular nitrifying microbial community was assessed by fluorescent in situ hybridization with specific oligonucleotide probes. The system showed an average removal of chemical oxygen demand (COD) equal to 76% for VOLRs between 2.6 and 13.6 kg COD m−3_media.day−1. The process of nitrification in conjunction with the removal of organic matter was observed from applying VOLRs lower than 5.5 kg COD m−3_media.day−1 resulting in 78% conversion of NH4+-N. As the applied organic load was reduced, an increase in the nitrifying bacteria population was observed compared with total 4′-6-diamidino-2-phenylindole (DAPI) stained cells. Generally, SAF using bottle caps as a biological aerated filter medium treating wastewater from an anaerobic system showed promising removal of chemical oxygen demand (COD) and conversion of NH4+-N.


2020 ◽  
Vol 15 (2) ◽  
pp. 142-151
Author(s):  
Peter Lukac ◽  
Lubos Jurik

Abstract:Phosphorus is a major substance that is needed especially for agricultural production or for the industry. At the same time it is an important component of wastewater. At present, the waste management priority is recycling and this requirement is also transferred to wastewater treatment plants. Substances in wastewater can be recovered and utilized. In Europe (in Germany and Austria already legally binding), access to phosphorus-containing sewage treatment is changing. This paper dealt with the issue of phosphorus on the sewage treatment plant in Nitra. There are several industrial areas in Nitra where record major producers in phosphorus production in sewage. The new wastewater treatment plant is built as a mechanicalbiological wastewater treatment plant with simultaneous nitrification and denitrification, sludge regeneration, an anaerobic zone for biological phosphorus removal at the beginning of the process and chemical phosphorus precipitation. The sludge management is anaerobic sludge stabilization with heating and mechanical dewatering of stabilized sludge and gas management. The aim of the work was to document the phosphorus balance in all parts of the wastewater treatment plant - from the inflow of raw water to the outflow of purified water and the production of excess sludge. Balancing quantities in the wastewater treatment plant treatment processes provide information where efficient phosphorus recovery could be possible. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. There are also two outflows - drainage of cleaned water to the recipient - the river Nitra - 9.9 kg Ptot/day and Ptot content in sewage sludge - about 120.3 kg Ptot/day - total 130.2 kg Ptot/day.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


Sign in / Sign up

Export Citation Format

Share Document