scholarly journals Association Between Central Corneal Thickness and Growth Parameters Following Preterm

2022 ◽  
Vol 8 (1) ◽  
pp. 28-32
Author(s):  
Gokhan CELIK ◽  
Murat GUNAY ◽  
Osman KIZILAY ◽  
Abdulhamit TÜTEN
Author(s):  
Lei Shi ◽  
Fabian Norbert Fries ◽  
Kassandra Xanthopoulou ◽  
Tanja Stachon ◽  
Loay Daas ◽  
...  

Abstract Purpose To analyze endothelial cell density (ECD) and central corneal thickness (CCT) following penetrating keratoplasty (PKP) in Acanthamoeba keratitis (AK) patients. Patients and Methods In this retrospective, clinical, single-center, cross-sectional, observational study, patients were enrolled who underwent PKP at the Department of Ophthalmology of Saarland University Medical Center, Homburg/Saar, Germany between May 2008 and December 2016 with the diagnosis of AK. In all, 33 eyes of 33 patients (14 males, 42%) were enrolled; their mean age at the time of surgery was 39.5 ± 14.3 years. Postoperatively, AK patients received topical polyhexamethylene biguanide, propamidine isethionate, neomycin sulphate/gramicidin/polymixin B sulfate, and prednisolone acetate eye drops (5 ×/day each), and the topical treatment was tapered sequentially with 1 drop every 6 weeks over 6 months. CCT was recorded using Pentacam HR Scheimpflug tomography and ECD with the EM-3000 specular microscope before surgery and 3 and 6 months after surgery as well as after the first and second (complete) suture removal. Results ECD tended to decrease significantly from the time point before surgery (2232 ± 296 cells/mm2) to the time point 3 months after surgery (1914 ± 164 cells/mm2; p = 0.080) and to the time point after the first suture removal (1886 ± 557 cells/mm2; p = 0.066) and decrease significantly to the time point after the second suture removal (1650 ± 446 cells/mm2; p = 0.028). CCT did not change significantly over the analyzed time period (p ≥ 0.475). Conclusion In AK, endothelial cell loss does not seem to be accelerated following PKP, despite the postoperative use of diamidine and biguanide. A subsequent prospective comparative study should confirm our retrospective longitudinal analysis.


Author(s):  
Bishr Agha ◽  
Nura Ahmad ◽  
Daniel G. Dawson ◽  
Thomas Kohnen ◽  
Ingo Schmack

Abstract Purpose To analyze refractive and topographic changes secondary to Descemet membrane endothelial keratoplasty (DMEK) in pseudophakic eyes with Fuchs’ endothelial dystrophy (FED). Methods Eighty-seven pseudophakic eyes of 74 patients who underwent subsequent DMEK surgery for corneal endothelial decompensation and associated visual impairment were included. Median post-operative follow-up time was 12 months (range: 3–26 months). Main outcome measures were pre- and post-operative manifest refraction, anterior and posterior corneal astigmatism, simulated keratometry (CASimK) and Q value obtained by Scheimpflug imaging. Secondary outcome measures included corrected distance visual acuity (CDVA), central corneal densitometry, central corneal thickness, corneal volume (CV), anterior chamber volume (ACV) and anterior chamber depth (ACD). Results After DMEK surgery, mean pre-operative spherical equivalent (± SD) changed from + 0.04 ± 1.73 D to + 0.37 ± 1.30 D post-operatively (p = 0.06). CDVA, proportion of emmetropic eyes, ACV and ACD increased significantly during follow-up. There was also a significant decrease in posterior corneal astigmatism, central corneal densitometry, central corneal thickness and corneal volume over time (p = 0.001). Only anterior corneal astigmatism and simulated keratometry (CASimK) remained fairly stable after DMEK. Conclusion Despite tendencies toward a hyperopic shift, changes in SE were not significant and refraction remained overall stable in pseudophakic patients undergoing DMEK for FED. Analysis of corneal parameters by Scheimpflug imaging mainly revealed changes in posterior corneal astigmatism pointing out the relevance of posterior corneal profile changes during edema resolution after DMEK.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.


2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Mahmoud Rateb ◽  
Mahmoud Abdel-Radi ◽  
Zeiad Eldaly ◽  
Mohamed Nagy Elmohamady ◽  
Asaad Noor El Din

Purpose. To evaluate the different IOP readings by Goldmann applanation tonometer (GAT), ICare rebound tonometer, and Tono-Pen in keratoconus patients after MyoRing implantation. To assess the influence of central corneal thickness (CCT) and thinnest corneal location (TCL) on IOP measurements by different tonometers. Setting. Prospective observational study was conducted in two private centers in Egypt from February 2015 to November 2016. Methods. Seventeen eyes of 10 patients suffering from keratoconus and who underwent MyoRing implantation were recruited. All subjects underwent GAT, ICare, and Tono-Pen IOP measurements in random order. Central corneal thickness and thinnest corneal location were assessed by Pentacam. Difference in mean in IOP readings was assessed by T-test. Correlation between each pair of devices was evaluated by Pearson correlation coefficient. The Bland–Altman analysis was used to assess intertonometer agreement. Results. Seventeen eyes (10 patients) were evaluated. The mean IOP reading was 13.9 ± 3.68, 12.41 ± 2.87, and 14.29 ± 1.31 mmHg in GAT, ICare, and Tono-Pen group, respectively. There was a significant difference between IOP readings by GAT/ICare and Tono-Pen/ICare (p value: 0.032 and 0.002, respectively) with no significant difference between GAT/Tono-Pen (p value: 0.554). Mean difference in IOP measurements between GAT/ICare was 1.49 ± 2.61 mmHg, Tono-Pen/ICare was 1.89 ± 2.15 mmHg, and GAT/Tono-Pen was −0.39 ± 2.59 mmHg. There was no significant correlation between the difference in IOP readings among any pair of devices and CCC or TCL. The Bland–Altman analysis showed a reasonable agreement between any pair of tonometers.


2016 ◽  
pp. 535 ◽  
Author(s):  
Mohammad Reza Djodeyre ◽  
Jaime Beltran ◽  
Julio Ortega-Usobiaga ◽  
Felix Gonzalez-Lopez ◽  
Ana Ruiz-Rizaldos ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document