scholarly journals EXPERIMENTAL STUDY OF A CYCLONE SCRUBBER AIR CONDITIONING SYSTEM USING FACTORIAL DESIGN

2014 ◽  
Vol 13 (1) ◽  
pp. 19
Author(s):  
R. B. Elias ◽  
A. A. B. Pécora

This work reports the results obtained in the experimental evaluation of an American type cyclone which has been modified and adapted to perform environmental air conditioning by evaporative cooling. Equipment was fitted with nozzles atomizers, which perform the injection of liquid transversely to the gas stream. The tests were carried out following a full factorial design of experiments in order to obtain the influence of the atomizer holes diameter and of the liquid/air flow ratio on the cyclone performance. The diameter of the atomizer insert holes was in the range of 2.8 to 3.6 mm and the liquid/air flow ratio was from 0.65 to 0.76 L/m3. The saturation efficiency (Es) of the cyclone was analyzed through the Response Surface Methodology (RSM). Saturation efficiencies between 45.9 and 62.2 % were obtained. The use of statistical techniques allowed the proposition of empirical correlations to predict the behavior of the system regarding the studied operational range. The results show that the cyclone scrubber equipment is a viable alternative to air conditioning for human standards.

2012 ◽  
Vol 164 ◽  
pp. 362-365
Author(s):  
Guang Zhen Cheng ◽  
Zuo Qing Liu ◽  
Hong Fei Lin

This paper provides a method of supply constant pressure air for air conditioning system. It analysis the energy consumption betwwen the damper adjuste air flow with variable frequency speed regulation adjuste air flow. The paper Introduce the Energy conservation principle of the frequency control blower. The supplying air Pipeline subject to a uniform force, the equipments mechanical properties was improved.The results show that Uses the frequency conversion velocity modulation to carry on supply constant pressure air, obviously reduces the energy consumption.The electrical motor starting characteristic is improved, realizes the electrical motor soft start.


2020 ◽  
Author(s):  
A. Saravanakumar ◽  
L. Rajeshkumar ◽  
N. S. Sanjay kumar ◽  
R. Sivakumar ◽  
S. Sriramthilak ◽  
...  

Solar Energy ◽  
2005 ◽  
Author(s):  
B. Zheng ◽  
X. Pang ◽  
M. Liu ◽  
I. Joo

A fan airflow station measures airflow through a fan using fan speed, fan head, and the field-calibrated fan curve. This paper presents the theory and techniques of using fan airflow station in a variable volume system for building pressure control. These techniques include fan curve calibration, determination of the volumetric flow difference of the supply and return airflows, and sensor locations. The return fan speed profiles were plotted, and data was collected on building pressure after implementing the fan air flow station. The Implementation of a fan air flow station demonstrates that the return fan speed can track the supply fan speed profile as building loads change, such that building pressure is maintained within a satisfactory range.


2019 ◽  
Vol 111 ◽  
pp. 01079
Author(s):  
Hikari Sakakibara ◽  
Takashi Akimoto ◽  
Hitomi Igarashi ◽  
Shunsuke Nakamura ◽  
Madoka Kimura

The “Strategic Energy Plan” implemented by the Cabinet of Japan in 2014 strives for zero energy building design for typical new construction by 2030. The present study focuses on a ductless and variable air conditioning system, using the Coanda effect, with the aim of reducing fan power, and saving of resources by reducing the space between the ceiling. In this study, we examined the air blowing method and evaluated thermal comfort using computational fluid dynamics as well as subjective perception of coolness in a midsize office. A draft zone was reduced by extending the interval between conditioned air outlets. However, if the extension of throw length was excessive, hot space would be formed near the air outlets, and there would be a risk of impacting thermal comfort. Moreover, we confirmed that the thermal comfort was generally favourable. In particular, perceived thermal comfort was better at the position in the office where the air flow landed on the upper body of the subjects. On the other hand, it decreased when the influence of the air flow was small, and at the point where air flow landed on the lower body of the subjects.


Author(s):  
Jayesh S ◽  
Jacob Elias ◽  
Manoj Guru

Inherent toxicity makes lead a banned material in solder alloy making process. Lead-tin alloy was a favorable alloy used for soldering in electronic packaging manufacturers. As a result of the ban on lead, electronics package industries were looking for novel lead free alloys which can substitute the conventional Sn-Pb alloy. Many alloys were discovered by the scientists. None of them were able to substitute the Sn-Pb alloy and become the market leader. In this paper a new composition with Sn, Cu and Ni is made to analyze which can potentially replace the lead containing solder alloy. Using the design of experiments method, the optimized composition of Cu and Ni is predicted. The full factorial design of experiments with two replications is used to find the optimized composition. Melting temperature, contact angle and hardness were taken as the critical output parameters. Results obtained shows that the optimum composition of Cu and Ni are 1 and 1% by wt.


2015 ◽  
Vol 23 (04) ◽  
pp. 1550027 ◽  
Author(s):  
Napoleon Enteria ◽  
Hiroshi Yoshino ◽  
Akashi Mochida ◽  
Rie Takaki ◽  
Akira Satake ◽  
...  

The desiccant-based air-conditioning system consists of many heat and mass transfer components operating together with air fans. The performance test using the multiple tracer gas dilution method is important for knowing the internal and external flow rates, including the air leakages. The results of the test show the actual internal air flow rates and the sources of air leakage, and also show the interaction of air in the air-conditioned lecture room and in the mechanical room. The performance test using the multiple tracer gas dilution method in air flow and air leakages is important for a detailed evaluation of any air-conditioning system such as this desiccant-based one.