scholarly journals COMPARATIVE ANALYSES OF THE THERMAL PERFORMANCE OF REFRIGERANTS R134A, R245fa, R407C AND R600a DURING FLOW BOILING IN A MICROCHANNELS HEAT SINK

2018 ◽  
Vol 17 (2) ◽  
pp. 57
Author(s):  
H. L. S. L. Leão ◽  
D. B. Marchetto ◽  
G. Ribatski

A comparative study of the performance of of refrigerants R134a, R407C, R245fa and R600a during flow boiling was performed for a 123x494 µm2 heat sink composed of 50 parallel rectangular microchannels. Heat transfer experimental results for heat fluxes up to 310 kW/m2, mass velocities from 300 to 800 kg/(m2 s), liquid subcoolings of 5 and 10 °C and saturation temperature close to 30 ºC were obtained. Global heat transfer coefficients (footprint) up to 10 kW/(m2 °C) were found. The liquid superheating necessary for the onset of nucleate boiling (ONB) was also characterized, and the fluids R245fa and R407C presented the highest and lowest, respectively, superheating to trigger the boiling process. Moreover, for a fixed averaged vapor quality, the average effective heat transfer coefficient increases with increasing mass velocity and liquid subcooling. The refrigerants R600a and R407C presented the highest and the lowest heat transfer coefficients, respectively. Five heat transfer predictive methods from literature provided accurate predictions of the data for R134a, R245fa and R600a, capturing most of the data trends. No one method provided accurate predictions of the heat transfer coefficient data of R407C.

Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 160 ◽  
Author(s):  
Bartosz Gil ◽  
Beata Fijałkowska

This paper investigates the nucleate boiling process of dimethyl ether and selected hydrocarbons. The main goal of this study is to measure the heat transfer coefficients of RE170, R600a, and R601, and to compare them with R134a. The experiments were carried out for heat fluxes up to 70 kW/m2. Experimental results have shown a typical trend that the heat transfer coefficient of flammable refrigerants increases as the heat flux increases. Among the tested fluids, the highest values of heat transfer coefficient were obtained for RE170. Available correlations describing this coefficient showed a deviation of up to 93%, as compared to the data obtained. The new correlation was developed by regression analysis taking into account dimensionless variables affecting the boiling process.


2016 ◽  
Vol 819 ◽  
pp. 181-185
Author(s):  
Agus Sunjarianto Pamitran ◽  
Ulfi Khabibah ◽  
Normah Mohd-Ghazali ◽  
Robiah Ahmad ◽  
Kiyoshi Saito

Hydrocarbon refrigerants have been widely used to replace HFCs. As hydrocarbon, R-290 has no ODP (Ozone Depletion Potential) and negligible GWP (Global Warming Potential). This paper presents flow boiling heat transfer in small tube with R-290 and R-22. The test tube has inner diameter of 7.6 mm and length of 1.07 m. In order to determine the heat transfer coefficient, experiments were carried out for heat fluxes ranging from 10 to 25 kW/m2, mass fluxes ranging from 204 to 628 kg/m2s, and saturation temperatures ranging from 1.87 to 11.9o C. The study analyzed the heat transfer through the local heat transfer coefficient along the flow under the variation of these different parameters. In comparison with R-22, R-290 provides higher heat transfer coefficients. In the prediction of the heat transfer coefficients of R-22 and R-290, the correlation of Shah (1982) and Choi et.al. (2009) best fitted the present experimental result, respectively.


Author(s):  
Francisco J. do Nascimento ◽  
Hugo L. S. L. Leão ◽  
Gherhardt Ribatski

In the present study, the thermal performance of a micro heat spreader based on flow boiling mechanism was evaluated. The heat spreader under study has a foot print area of 15 × 15 mm2 and is composed by 50 channels with width of 100 μm and depth of 500 μm. Experiments were performed for R134a, heat fluxes up to 310 kW/m2 (based on the foot print area), mass velocities from 400 to 1500 kg/m2s, saturation temperatures of approximately 25°C and liquid subcoolings of 5 and 15°C. Heat-sink averaged heat transfer coefficients based on the effective heat transfer area up to 9 kW/m2K were obtained. From the analyses of the experimental results, for a fixed heat-spreader averaged wall superheating, it was found that the dissipated heat flux increases with decreasing the mass velocity and liquid subcooling. Moreover, the trend with varying mass velocity of the difference between the heat spreader averaged superheating for the onset of nucleate boiling (ONB) and the respective value under boiling conditions is not clear, however it seems that its value increases with increasing the liquid subcooling. The wall superheating excess necessary for the onset of nucleate boiling becomes negligible for mass velocities higher than 1000 kg/m2s.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


2000 ◽  
Author(s):  
Edward V. McAssey ◽  
Jinfeng Wu ◽  
Thomas Dougherty ◽  
Bao Wen Yang

Abstract Data are presented for sub-cooled boiling of water in the range of two to four atmospheres. The results show that the sharp increase in heat transfer coefficient associated with nucleate boiling occurs at wall superheats of 20 °C to 30 °C. Comparisons between experimental and predicted heat transfer coefficients are also presented. The two prediction methods examined are the Chen correlation and the Kandlikar correlation.


Author(s):  
Ayman Megahed ◽  
Ibrahim Hassan ◽  
Tariq Ahmad

The present study focuses on the experimental investigation of boiling heat transfer characteristics and pressure drop in a silicon microchannel heat sink. The microchannel heat sink consists of a rectangular silicon chip in which 45 rectangular microchannels were chemically etched with a depth of 295 μm, width of 254 μm, and a length of 16 mm. Un-encapsulated Thermochromic liquid Crystals (TLC) are used in the present work to enable nonintrusive and high spatial resolution temperature measurements. This measuring technique is used to provide accurate full and local surface-temperature and heat transfer coefficient measurements. Experiments are carried out for mass velocities ranging between 290 to 457 kg/m2.s and heat fluxes from 6.04 to 13.06 W/cm2 using FC-72 as the working fluid. Experimental results show that the pressure drop increases as the exit quality and the flow rate increase. High values of heat transfer coefficient can be obtained at low exit quality (xe < 0.2). However, the heat transfer coefficient decreases sharply and remains almost constant as the quality increases for an exit quality higher than 0.2.


Author(s):  
Chih-Jung Kuo ◽  
Yoav Peles

Flow boiling in parallel microchannels with structured reentrant cavities was experimental studied. Flow patterns, boiling inceptions and heat transfer coefficients were obtained and studied for G = 83 kg/m2-s to G = 303 kg/m2-s and heat fluxes up to 643 W/cm2. The heat transfer coefficient-mass velocity and quality relations had been analyzed to identify boiling mechanism. Comparisons of the performance of the enhanced and plain-wall microchannels had also been made. The microchannels with reentrant cavities were shown to promote nucleation of bubbles and to support significantly better reproducibility and uniformity of bubble generation.


2004 ◽  
Vol 120 ◽  
pp. 269-276
Author(s):  
M. Maniruzzaman ◽  
R. D. Sisson

Quenching heat treatment in a liquid medium is a very complex heat transfer process. Heat extraction from the part surface occurs through several different heat transfer mechanisms in distinct temperature ranges, namely, film boiling, partial film boiling (i.e. transition), nucleate boiling and convection. The maximum heat transfer occurs during the nucleate boiling stage. Experimental study shows that, the effective surface heat transfer coefficient varies more than two orders of magnitude with the temperature during the quenching. For quenching process simulation, accurate prediction of the time-temperature history and microstructure evolution within the part largely depends on the accuracy of the boundary condition supplied. The heat transfer coefficient is the most important boundary condition for process simulation. This study focuses on creating a database of heat transfer coefficients for various liquid quenchant-metallic alloy combinations through experimentation using three different quench probes. This database is a web-based tool for use in quench process simulation. It provides at-a-glance information for quick and easy analysis and sets the stage for a Decision Support System (DSS) and Data Mining for heat-treating process.


Author(s):  
Pega Hrnjak ◽  
Seongho Kim

Flow boiling heat transfer characteristics of CO2 with and without oil were investigated experimentally in horizontal smooth and enhanced tubes with an inner diameter of 11.2 mm. The visualization of flow pattern provides a detailed attributes of the nucleate and the convective boiling heat transfer. In order to investigate the effect of the miscible oil on the heat transfer of CO2, POE (polyolester) RENSIO C85E oil is added to give an oil circulation rate (OCR) between 0.5% and 2%. Results are compared with those of pure CO2. The experimental conditions include evaporation temperatures of −15 °C, mass fluxes from 40 to 200 kg/m2 s, heat fluxes from 0.5 to 10 kW/m2, and vapor qualities from 0.1 to 0.8. Oil generally deteriorates the heat transfer coefficient of pure CO2. The reduction in heat transfer coefficient is most apparent at low vapor qualities, 0.1 to 0.4, and at low mass fluxes, 100 and 200 kg/m2. It is caused by the suppression of nucleate boiling due to increased surface tension. At conditions where the convective boiling contribution is dominant, vapor qualities above 0.5, oil increases heat transfer coefficients. Through visualization, it is shown that the wetted area on the perimeter of inner tube is enhanced due to formation of foaming in the smooth tube. However, such enhancement of heat transfer due to forming is negligible in the enhanced tube, because the enhanced factor due to micro-finned structures is dominant.


2008 ◽  
Vol 12 (3) ◽  
pp. 33-44 ◽  
Author(s):  
Raja Balakrishnan ◽  
Lal Dhasan ◽  
Saravanan Rajagopal

An investigation on in-tube flow boiling heat transfer of R-134a/R-290/R-600a (91%/4.068%/4.932% by mass) refrigerant mixture has been carried out in a varied heat flux condition using a tube-in-tube counter-flow test section. The boiling heat transfer coefficients at temperatures between -5 and 5?C for mass flow rates varying from 3 to 5 g/s were experimentally arrived. Acetone is used as hot fluid, which flows in the outer tube of diameter 28.57 mm, while the test fluid flows in the inner tube of diameter 9.52 mm. By regulating the acetone flow rate and its entry temperature, different heat flux conditions between 2 and 8 kW/m2 were maintained. The pressure of the refrigerant was maintained at 3.5, 4, and 5 bar. Flow pattern maps constructed for the considered operating conditions indicated that the flow was predominantly stratified and stratified wavy. The heat transfer coefficient was found to vary between 500 and 2200 W/m2K. The effect of nucleate boiling prevailing even at high vapor quality in a low mass and heat flux application is high-lighted. The comparison of experimental results with the familiar correlations showed that the correlations over predict the heat transfer coefficients of this mixture.


Sign in / Sign up

Export Citation Format

Share Document