DEVELOPMENT AND VALIDATION OF NOVEL STABILITY INDICATING RP-HPLC METHOD FOR QUANTIFICATION OF TOLVAPTAN IN BULK AND PHARMACEUTICAL DOSAGE FORM

INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (03) ◽  
pp. 62-68
Author(s):  
Khaleel Noorbasha ◽  
S. K. Abdul Rahaman

Specific stability-indicating reversed-phase high performance liquid chromatography (HPLC) method has been developed and validated for the quantification of tolvaptan in bulk drug and pharmaceutical dosage form. The optimized conditions for the developed HPLC method are; Inertil ODS-3V column (150 x 4.6 mm, 5.0 mm) maintained at 30°C with mobile phase consisting of 0.1% ortho phosphoric acid and acetonitrile in the ratio 40:60%v/v on isocratic mode at flow rate of 1.0 mL/min and detection wavelength 254 nm. The retention time of tolvaptan was found to be 2.59 min with linearity in the concentration range from 37.5 – 225.0 µg/mL, respectively. The mean percentage recovery of tolvaptan was found to be 98.30 – 101.13 %, respectively. The percent relative standard values were less than 2.0 at all the levels and indicates a satisfactory accuracy and precision. The robustness of the method found to meet the acceptance criteria. The stress study against qualified working standard of Tolvaptan, indicated that the developed HPLC method was stability- indicating, conducted as per ICH requirements. The developed method can be handy in the quality control of bulk and pharmaceutical dosage forms.

Author(s):  
Jahnavi Bandla ◽  
S. Ganapaty

Objective: The objective of the present study was to develop and validate a new stability-indicating method for the quantification of lenvatinib mesylate in bulk drug and pharmaceutical dosage form using ultra performance liquid chromatography (UPLC).Methods: The optimized chromatographic conditions for elution of drug included UPLC HSS C18 (100 mm × 2.1 mm, 1.8 m) column, mixture of 0.1% orthophosphoric acid and acetonitrile (50:50 v/v%) mobile phase run on an isocratic mode at a flow rate of 0.3 mL/min, 240 nm detection wavelength, and column oven temperature maintained at 30°C.Results: The retention time for lenvatinib was found to be 1.24 min. The developed method was validated for various validation parameters in accordance with the International Conference on Harmonization guidelines. The method obeyed Beer’s law in the concentration range of 2.5– 15 μg/mL with a correlation coefficient of 0.9996. The percentage relative standard deviation and percentage recovery were determined to be 0.4 and 99.66–100.30%, respectively. The developed method was found to be accurate, precise, specific, linear, rugged, and robust. Forced degradation studies were conducted by exposing the drug to diverse stress conditions such as acidic, basic, peroxide, neutral, photolytic, and thermal conditions. The net degradation was obtained within the limits.Conclusion: The developed method for the estimation of lenvatinib can be employed to routine analysis of pharmaceutical dosage form.


Author(s):  
VEERASWAMI B ◽  
NAVEEN VMK

Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of dolutegravir (DTG) and rilpivirine (RPV) in bulk and pharmaceutical dosage form and rat plasma. Methods: The chromatographic separation was achieved on Phenomenex C18 (150x4.6mm, 5μm). Mobile phase contained a mixture of 0.1% Ortho phosphoric acid and acetonitrile in the rato of 60:40 v/v, flow rate 1.0ml/min and ultraviolet detection at 262nm. Results: The retention time of DTG and RPV was 4.35 min and 7.73 min, respectively. The proposed method shows a good linearity in the concentration range of 10–150 μg/ml for DTG and 5–75 μg/ml for RPV under optimized conditions. Precision and recovery study results are in between 98 and 102%. In the entire robustness conditions, percentage relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. DTG and RPV drugs are release 98% at 2 h in rat body. Conclusion: This method is validated for different analytical performance parameters like linearity. Precision, accuracy, limit of detection, limit of quantification, robustness, and pharmacokinetic study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. All the parameters of validation were found in the acceptance range of ICH guidelines. The same method is also applied for plasma samples study in bioanalytical work.


Author(s):  
Y. Rajesh Babu ◽  
N. Appalaraju

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Imatinib mesylate in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Imatinib mesylate in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Imatinib mesylate in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


Author(s):  
Sirajunisa Talath ◽  
Syeda Humaira

The objective of this work was to develop a simple, sensitive, accurate, precise and reproducible high performance liquid chromatography (HPLC) method for the determination of norfloxacin in pharmaceutical dosage forms. Shimadzo Prominance model L20 AD HPLC system equipped with SPD 20A UV-Vis detector was used for the analysis. The separation was done on RESTEX allure C18 column (3 μm, 15 cm × 4.6 mm), for an isocratic elution a mixture of methanol and water (60:40, v/v) mobile phase at a wavelength of 254 nm. The flow rate was 1.0 mL/min. The RP-HPLC method developed for analysis of norfloxacin was validated with respect to specificity, selectivity, linearity, accuracy, precision and robustness as per the ICH guidelines. The retention time of norfloxacin was 7.5 min. The linearity was established over the concentration ranges of 50-350 μg/mL with correlation coefficients ( r2) 0.999.  The percentage accuracy of norfloxacin ranged from 99.76 -101.66%. The relative standard deviation values for intra-day and inter-day precision was lower than 2.0% and the assay result was found to be 100.65 %. Norfloxacin was subjected to stress conditions such as neutral, acidic, alkaline, oxidation and photolysis degradations as per ICH guidelines. The degradation studies revealed that the drug was found to degrade maximum (1.67%) in alkaline degradation conditions and was highly resistant towards neutral, acidic, oxidative and photolytic degradation conditions. Keywords: Norfloxacin, Validation, Stability-indicating, stress degradation, ICH guidelines.  


2021 ◽  
Vol 12 (8) ◽  
pp. 52-57
Author(s):  
Chaitali R Dhale ◽  
Rao J R

A simple and specific stability indicating reversed-phase high-performance liquid chromatography technique has been developed and validated for the concurrent estimation of metformin hydrochloride and dapagliflozin in bulk and pharmaceutical dosage form. The ideal conditions were established for the study or analysis of the drug such as chromatographic separation was carried out on THERMO fisher ODS C18 column containing mobile phase of water and acetonitrile 65:35 % v/v of pH 6.8 adjusted with 0.1 % ortho phosphoric acid at a flow rate of 1 ml/minutes detected wavelength at 240 nm. The retention time was found to be 2.13 minutes and 5.41 minutes for metformin hydrochloride (MET) and dapagliflozin (DAPA) respectively. The proposed method was found to be linear in the concentration range of 100-600 ug/ml for MET (R2=0.9999) and 1-6 ug/ml for DAP (R2=0.9996), respectively. Method was validated according to ICH guidelines. Co-relation coefficients for both the drugs were found to be less than one. The mean % recoveries obtained were found to be 99.06-100.32% for metformin and 99.1-100.18% for dapagliflozin respectively. Stress testing is carried out for both drugs in acid, base, peroxide, photolytic and thermal degradation. The developed method can be effectively applied for routine analysis in simultaneous determination of metformin hydrochloride and dapagliflozin in bulk and combined tablet dosage form.


Author(s):  
Rajesh Babu Y. ◽  
Appala Raju N.

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Pazopanib hydrochloride in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Pazopanib hydrochloride in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Pazopanib hydrochloride in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


Author(s):  
Pooja Pisal ◽  
Ganesh Nigade ◽  
Amol Kale ◽  
Smita Pawar

Objective: To develop a novel, accurate, precise and linear reverse phase high-performance liquid chromatography (RP-HPLC) and Stability Indicating Assay Method (SIAMs) for simultaneous, qualitative and quantitative estimation of aspirin, rosuvastatin and clopidogrel in bulk and pharmaceutical dosage form as per International Conference on Harmonization (ICH) guidelines.Method: In the present work, good chromatographic separation was achieved by isocratic method using a BISCOF HPLC C18 column (250 mm ×4.6, 5 µm) and a mobile phase consisting of water at pH 2.51 with 0.1 % (v/v) orthophosphoric acid (OPA): acetonitrile in the ratio 50:50, at a flow rate of 1 ml/min. The effluents obtained were monitored at 237 nm with the UV-visible detector.Results: The retention time of aspirin, rosuvastatin, and clopidogrel was found to be 4.3 min, 7.6 min and 16.6 min respectively. For linearity seven-point calibration curves were obtained in a concentration range from 1-7 µg/ml for aspirin, rosuvastatin and clopidogrel with correlation coefficient 0.999, 0.9989, 0.9988 respectively. The high recovery values (99%-101%) indicate a satisfactory accuracy. The low percent relative standard deviation (% RSD) values in the precision study reveal that the method is precise. In the present study stability indicating an RP-HPLC method for the combination was tested by degrading the drugs together under various stress condition like acid, base and neutral hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH.Conclusion: The developed RP-HPLC method is simple, economic, specific, accurate and precise for the simultaneous estimation of aspirin, rosuvastatin, and clopidogrel in the combined capsule dosage form. The developed stability indicating analytical method can be used to check the stability of the compounds and was found suitable to determine % degradation of drugs in pharmaceutical dosage form.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (11) ◽  
pp. 46-50
Author(s):  
Z. G Khan ◽  
◽  
S. S. Patil ◽  
P. K. Deshmukh ◽  
P. O. Patil

Novel, isocratic reversed phase high performance liquid chromatography method was developed and validated for the determination of enzalutamide (EZA) in bulk drug and pharmaceutical formulation. Efficient separation was achieved on PrincetonSPHER C18 100A, 5μ (250×4.6 mm) under the isocratic mode of elution using acetonitrile: water (80:20) % V/V as a mobile phase pumped in to the column at flow rate 1.0 mL/min. The effluent was monitored at 237.0 nm using UV detector. EZA was eluted in the given mobile phase at retention time (tR) of 3.2 minutes. The standard calibration curve was linear over the concentration range 10 - 60 μg/mL with correlation coefficient 0.997. The method was validated for accuracy, precision, sensitivity, robustness, ruggedness and all the resulting data treated statistically. The system suitability parameters like retention time, theoretical plates, tailing factor, capacity factor were found within the limit.


Author(s):  
PULAGURTHA BHASKARARAO ◽  
GOWRI SANKAR DANNANA

Objective: Noscof tablet is a fixed dosage combination formulation having diphenhydramine (DH), ephedrine (ED), noscapine (NP), and glycerol glycolate (GG). A sensitive, selective, accurate, precise, and stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method with photodiode array detection has been developed and validated for simultaneous analysis of DH, ED, NP, and GG in bulk drug and Noscof tablets. Methods: Reversed-phase chromatographic separation and analysis of DH, ED, NP, and GG were done on an Altima C18 column with 0.01 M KH2PO4 buffer (pH 3.5) and acetonitrile (50:50%, v/v) as mobile phase at 0.8 ml/min flow rate in isocratic mode. Detection was performed at 260 nm. The method was validated in harmony with International Conference on Harmonization (ICH) guidelines. The tablet sample solution was subjected to diverse stress conditions using ICH strategy such as hydrolytic degradation (neutral - with distilled water, alkaline - with 2 N NaOH, and acidic - with 2 N HCl), oxidation (with 10% H2O2), photodegradation (exposing to UV light), and dry heat degradation (exposing to 105°C). Results: Using the above stated chromatographic conditions, sharp peaks were obtained for ED, NP, DH, and GG with retention time of 3.272 min, 4.098 min, 5.467 min, and 6.783 min, respectively. Good regression coefficient values were obtained in the range of 2–12 μg/ml for ED, 3.75–22.5 μg/ml for NP, 3.125–18.75 μg/ml for DH, and 25–150 μg/ml for GG. The quantification limits were 0.181 μg/ml, 0.187 μg/ml, 0.246 μg/ml, and 1.114 μg/ml for ED, NP, DH, and GG, respectively. The values of validation parameters are within the acceptance limits given by ICH. The ED, NP, DH, and GG showed more percent of degradation in acid condition and less percent of degradation in the neutral condition. The peaks of degradants did not interfere with the peaks of analytes. ED, NP, DH, and GG were assessed with a good percentage of the assay (near to 100%) and low percent relative standard deviation (<2%) in Noscof tablets using the proposed method. Conclusion: The stability indicating RP-HPLC method developed was suitable for quantifying ED, NP, DH, and GG simultaneously in bulk as well as in tablet formulation.