scholarly journals An estimate of ground heat flux for a seasonal snow cover

MAUSAM ◽  
2021 ◽  
Vol 50 (2) ◽  
pp. 153-158
Author(s):  
A. K. SINGH

An estimation of ground heat flux for two locations has been done using temperature gradient method. Effective media approach has been adopted for predicting the effective thermal conductivity of ground. For comparison, in situ measurement of effective thermal conductivity of ground has also been done by thermal probe method. The measured values of thermal conductivity are in agreement with the calculated values. The estimated values of ground heat flux have been used to evaluate the melt rate at ground-snow interface.

1971 ◽  
Vol 45 (4) ◽  
pp. 759-768 ◽  
Author(s):  
M. M. R. Williams

The effect of a temperature gradient in a gas inclined at an angle to a boundary wall has been investigated. For an infinite half-space of gas it is found that, in addition to the conventional temperature slip problem, the component of the temperature gradient parallel to the wall induces a net mass flow known as thermal creep. We show that the temperature slip and thermal creep effects can be decoupled and treated quite separately.Expressions are obtained for the creep velocity and heat flux, both far from and at the boundary; it is noted that thermal creep tends to reduce the effective thermal conductivity of the medium.


2000 ◽  
Vol 123 (1) ◽  
pp. 63-64 ◽  
Author(s):  
S. S. Sazhin ◽  
V. A. Gol'dshtein ◽  
M. R. Heikal

Newton's law of cooling is shown to underestimate the heat flux between a spherical body (droplet) and a homogeneous gas after this body is suddenly immersed into the gas. This problem is rectified by replacing the gas thermal conductivity by the effective thermal conductivity. The latter reduces to the gas thermal conductivity in the limit of t→∞, but can be substantially higher in the limit of t→0. In the case of fuel droplet heating in a medium duty truck Diesel engine the gas thermal conductivity may need to be increased by more than 100 percent at the initial stage of calculations to account for transient effects during the process of droplet heating.


2018 ◽  
Vol 36 (5) ◽  
pp. 419-437 ◽  
Author(s):  
Jiyuan Kang ◽  
Fumiaki Takahashi ◽  
James S T’ien

Thermal insulating performance and char-layer properties have been studied for water-based intumescent coatings for structural steel fire protection using a new laboratory-scale mass-loss cone apparatus. A specimen (100 × 100 mm mild steel plate; the initial coating thickness: 0.3–2.0 mm) is placed horizontally and exposed to a constant incident radiant heat flux (25, 50, or 75 kW/m2). The apparent thermal conductivity of the expanding char layer is determined in situ based on real-time measurements of the temperature distribution in the char layer and the heat flux transmitted through the char layer. Three-dimensional morphological observations of the expanded char layer are made using a computed tomographic–based analytical method. The vertical variation of the porosity of the expanded char layer is measured. The measured heat-blocking efficiency is correlated strongly with the incident heat flux, which increases the expanded char-layer thickness, and porosity for sufficiently large initial coating thicknesses (>0.76 mm). For a thin coating (0.30 mm), violent off-gassing disrupts the intumescing processes to form a consistent char layer after abrupt exposure to higher incident heat fluxes, thus resulting in lower heat-blocking efficiency. Therefore, the product application thickness must exceed a proper threshold value to ensure an adequate thermal insulation performance.


2021 ◽  
Vol 2096 (1) ◽  
pp. 012165
Author(s):  
Yu P Zarichnyak ◽  
A Yu Gorbunova ◽  
V A Korablev ◽  
V A Ivanov ◽  
N V Pilipenko ◽  
...  

Abstract A model of a tube with a square cross-section was compiled for the mathematical analysis of the mesotube in Cartesian coordinates, with the selection of an element of a representative volume. To estimate the effective thermal conductivity of the structure, the generalized theory of conductivity with linearization of heat flux streamlines was used. The presence of anisotropy leads to the division of the problem into a separate estimate of the longitudinal and transverse thermal conductivity. The cross-section of the model was divided into elementary sections by a system of auxiliary adiabatic and isothermal planes, then the sections of the model were presented in the form of thermal resistances connected in chains - electrical circuits. Using the analogy of the identity of thermal and electrical resistances, the total conductivity of the sections and the effective thermal conductivity of the structure were determined. This methodology satisfies the test for limit transitions.


2008 ◽  
Vol 49 ◽  
pp. 43-50 ◽  
Author(s):  
P.K. Satyawali ◽  
A.K. Singh ◽  
S.K. Dewali ◽  
Praveen Kumar ◽  
Vinod Kumar

AbstractThis paper presents a sequential evaluation of snow microstructure and its associated thermal conductivity under the influence of a temperature gradient. Temperature gradients from 28 to 45 Km–1 were applied to snow samples having a density range 180–320 kgm–3. The experiments were conducted inside a cold room in a specially designed heat-flux apparatus for a period of 4weeks. A constant heat flux was applied at the base of the heat-flux apparatus to produce a temperature gradient in the snow sample. A steady-state approach was used to estimate the effective thermal conductivity of snow. Horizontal and vertical thick sections were prepared on a weekly basis to obtain snow micrographs. These micrographs were used to obtain snow microstructure using stereological tools. The thermal conductivity was found to increase with increase in grain size, bond size and grain and pore intercept lengths, suggesting a possible correlation of thermal conductivity with snow microstructure. Thermal conductivity increased even though surface area and area fraction of ice were found to decrease. The outcome suggests that changes in snow microstructure have significant control on thermal conductivity even at a constant density.


2000 ◽  
Author(s):  
Y. H. Yan ◽  
J. M. Ochterbeck

Abstract A two-dimensional numerical model was established to study the behavior of a cylindrical capillary pumped loop evaporator under steady-state operations. The influence of heat load, liquid subcooling and effective thermal conductivity of the wick structure on the evaporator performance were studied. It was found that increasing the applied heat flux and degree of liquid subcooling resulted in a decrease the temperature in the liquid core. This helped to prevent the vapor from generating in the liquid core and decreased the length of the two phase region in the wick structure. Decreasing the effective thermal conductivity also decreases the temperature in the liquid core as related to the back wick condition. It was observed that for a given liquid subcooling, a minimum heat flux exists below which vapor will generate in the liquid core and render the evaporator non-operational. It was also observed that for a given heat flux, a minimum required liquid subcooling exists. Vapor may form in the liquid core when the liquid subcooling is less than the minimum value.


Sign in / Sign up

Export Citation Format

Share Document