scholarly journals Electrochemical sensor for determination of hydroxylamine using functionalized Fe3O4 nanoparticles and graphene oxide modified screen-printed electrode

Author(s):  
Hamed Tashakkorian ◽  
Behnaz Aflatoonian ◽  
Peyman Mohammadzadeh Jahani ◽  
Mohammad Reza Aflatoonian

A simple strategy for determination of hydroxylamine based on Fe3O4 nanoparticles function­nalized by [2-(4-((3-(trimethoxysilyl)propylthio)methyl)1-H1,2,3-triazol-1-yl)acetic­acid] (FNPs) and graphene oxide (GO) modified screen-printed electrode (SPE), denoted as (Fe3O4 FNPs/GO/SPE), is reported. The electrochemical behavior of hydroxylamine was investigated at Fe3O4FNPs/GO/SPE by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chro­noamperometry (CHA) techniques in phosphate buffer solution (pH 7.0). Fe3O4 FNPs/GO/SPE as a novel electrochemical sensor exhibited catalytic activity toward the oxidation of hydroxyl­ami­ne. The potential of hydroxylamine oxidation was shifted to more negative potentials, and its oxidation peak current increased on the modified electrode, also indicating that under these conditions, the electrochemical process is irreversible. The electrocatalytic current of hydroxyl­amine showed a good relationship in the concentration range of 0.05–700.0 μM, with a detection limit of 10.0 nM. The proposed electrode was applied for the determination of hydroxyl­amine in water samples, too.

2019 ◽  
Vol 9 (2) ◽  
pp. 113-123 ◽  
Author(s):  
Sayed Zia Mohammadi ◽  
Hadi Beitollahi ◽  
Tahereh Rohani ◽  
Hossein Allahabadi

Electrochemical characteristics of carvacrol were investigated on a screen-printed electrode (SPE) modified with La2O3/Co3O4 nanocomposite by using voltammetric techniques, which displayed a well-defined peak for sensitive carvacrol determination in phosphate buffer solution (PBS) at pH 7.0. La2O3/Co3O4 nanoparticles demonstrated suitable catalytic activity for carvacrol determination by differential pulse voltammetry (DPV) technique. Besides, determination of carvacrol in a real samples was recognized in the light of electrochemical findings and a validated voltammetric technique for quantitative analysis of carvacrol in a real formulation was proposed. The DPV peak currents were found to be linear in the concentration range of 10.0 to 800.0 μM. The limit of detection (LOD) was found to be 1.0 μM.


2019 ◽  
Vol 9 (3) ◽  
pp. 187-195 ◽  
Author(s):  
Somayeh Tajik ◽  
Hadi Beitollahi ◽  
Mohammad Reza Aflatoonian

Flower-like La3+/ZnO nanocomposite was facile synthesized. A simple and ultrasensitive sensor based on graphite screen printed electrode (SPE) modified by La3+/ZnO nanoflower was developed for the electrochemical determination of dopamine. The electrochemical behavior of dopamine was studied in 0.1 M phosphate buffer solution (PBS) using cyclic voltammetry (CV), chronoamperometry (CA) and differential pulse voltammetry (DPV). Compared with the unmodified graphite screen printed electrode, the modified electrode facilitates the electron transfer of dopamine, since it notably increases the oxidation peak current of dopamine. Also, according to CV results the maximum oxidation of dopamine on La3+/ZnO/SPE occurs at 150 mV which is about 140 mV more negative compared with unmodified SPE. Under optimized conditions, the modified electrode exhibited a linear response over the concentration range from 0.15 to 300.0 μM, with a detection limit of 0.08 μM (S/N = 3). The proposed sensor exhibited a high sensitivity, good stability and was successfully applied for dopamine determination in dopamine ampoule, with high recovery.


2019 ◽  
Vol 11 (30) ◽  
pp. 3866-3873 ◽  
Author(s):  
R. Karthikeyan ◽  
D. James Nelson ◽  
S. Abraham John

Selective and sensitive determination of one of the purine nucleotides, inosine (INO) using a low cost carbon dot (CD) modified glassy carbon (GC) electrode in 0.2 M phosphate buffer solution (pH 7.2) was demonstrated in this paper.


Author(s):  
Abolfazl Darroudi ◽  
Saeid Nazari ◽  
Seyed Ali Marashi ◽  
Mahdi Karimi-Nazarabad

Abstract An accurate, rapid, simple, and novel technique was developed to determine simvastatin (SMV). In this research, a screen-printed electrode (SPE) was deposited with graphene oxide (GO) and sodium dodecyl sulfate (SDS), respectively. For the first time, the handmade modified SPE measured the SMV by differential pulse voltammetry (DPV) with high sensitivity and selectivity. The results of cyclic voltammetry indicated the oxidation irreversible process of SMV. Various parameters (pH, concentration, scan rate, support electrolyte) were performed to optimize the conditions for the determination of SMV. Under the optimum experiment condition of 0.1 M KNO3 as support electrolyte and pH 7.0, the linear range was achieved for SMV concentration from 1.8 to 36.6 µM with a limit of detection (LOD), and a limit of quantitation (LOQ) of 0.06 and 1.8 µM, respectively. The proposed method was successfully utilized to determine SMV in tablets and urine samples with a satisfactory recovery in the range of 96.2 to 103.3%.


2020 ◽  
Vol 8 (33) ◽  
pp. 7539-7547
Author(s):  
Xinrui Liu ◽  
Rajalakshmi Sakthivel ◽  
Yu-Cheng Chen ◽  
Ning Chang ◽  
Udesh Dhawan ◽  
...  

We have developed an electrochemical sensor based on integrated 2D materials including SnS2, graphene oxide, and β-cyclodextrin forming a ternary nanocomposite decorated on a screen-printed electrode for the electrochemical detection of melatonin.


2012 ◽  
Vol 600 ◽  
pp. 238-241
Author(s):  
Xiao Ling Qiang ◽  
Jian Fei Xia ◽  
Zong Hua Wang ◽  
Yan Zhi Xia ◽  
Fei Fei Zhang ◽  
...  

Copper (Cu) nanoparticles have been electrochemically deposited onto the glassy carbon electrode (GCE) surface by potentiostatic deposition method and then carbon nanotubes (CNTs) was dropped on the nano-Cu modified electrode surface to get a CNTs/nano-Cu/GCE electrode. The CNTs/nano-Cu/GCE has shown much higher electrocatalytic activity than the CNTs/GCE towards the oxidation of dopamine (DA) and uric acid (UA) in a phosphate buffer solution (pH 6.9). It can be applied to determine DA and UA with satisfactory results.


2011 ◽  
Vol 110-116 ◽  
pp. 519-526 ◽  
Author(s):  
Ning Gan ◽  
Ling Hua Meng ◽  
Fu Tao Hu ◽  
Yu Ting Cao ◽  
Yuan Zhao Wu ◽  
...  

A novel disposable screen-printed immunosensor for rapid determination of highly sensitive C reactiveprotein (hs-CRP) in human serum has been developed in the experiment. The sensor was constructed on one screen-printed carbon electrode (SPCE) with HRP labeled anti-hs-CRP antibody functionalized Fe3O4@Au magnetic nanoparticles (HRP labeled anti hs-CRP/ Fe3O4@Au) as the biorecognition probes attracted on the surface of Fe (III) phthalocyanine (FePc)/ chitosan membrane modified screen-printed carbon electrode (SPCE|FePc/Chit/chitosan) by external magnetic field. FePc was acted as electron immediate. The modified electrode shows an excellent electrocatalytic activity for hs-CRP in phosphate buffer solution (pH=7.0). After the immunosensor is incubated with hs-CRP antigen solution at 37°C for 20 min, the access of activity center of the HRP to electrode is partly inhibited, which leads to a linear decrease of the catalytic efficiency of the HRP to the reduction of immobilized FePc by H2O2 at –50 mV in hs-CRP’s concentration ranges from 1.2 to 200 ng/mL. The detection limit was 0.5ng/mL. The immunosensor was successfully utilized for determination of hs-CRP in real serum samples of heart disease patients, whose results were consistent with that by ELISA method. The accuracy and precision of the assay were 91.5-104.4% and 15.8-24.4%, respectively. The immunosensor was reusable once constructed and can be regenerated by adding new nanoprobes on the surface of basal electrode through magnet on its bottom. It can greatly reduce the detection cost which is valuable for the early diagnosis of tumors.


2022 ◽  
Author(s):  
Srikanth Ponnada ◽  
Demudu Babu Gorle ◽  
Maryam Sadat Kiai ◽  
Venkateswara raju Chikkili ◽  
M. Faraji ◽  
...  

A pioneering CuBTABB-MOF/rGO composite customized electrode is fabricated and utilized as a sensor towards identifying Bisphenol A (BPA) ina phosphate buffer solution of pH7.0. Composite is characterized by FTIR, Raman...


Sign in / Sign up

Export Citation Format

Share Document