Comparison of Selective Local and Global Muscle Thicknesses in Females with and without Chronic Low Back Pain

2018 ◽  
Vol 20 (3) ◽  
pp. 197-204 ◽  
Author(s):  
Mahnaz Aboufazeli ◽  
Mohammad Akbari ◽  
Ali Ashraf Jamshidi ◽  
Mohammad Saleh Jafarpisheh

Background. Chronic low back pain (LBP) leads to long-term physical and psychological problems and may result in acute deterioration of the pain. It is hypothesized that size changes in selected limb and pelvis muscles during contracting movements are different between healthy individuals and LBP patients. Materials and methods. A case-control study including two groups of 30 female participants with and without LBP symptoms was designed. Participants were 20-45 years old (36.7±6.7, healthy subjects; 34.6±6.2 LBP subjects). Ultrasonography was used to estimate the thicknesses of the quadratus lumborum (QL), gluteus medius (GMed), transversus abdominis (TrA) and lumbar multifidus (MF). Thickness changes of the muscles in a submaximal contracting position compared to the rest position were measured. Statistical analysis included an independent t-test to determine the significance of differences, and the Kolmogrov-Smirnov two-sample test to evaluate the normality and reliability. Results. All muscles increased their thickness during contractions. The average increase in LBP subjects was lower than in the healthy subjects. The smaller increase in the muscle thickness of GMed in the LBP group may suggest a weakness because of imbalance in the GMed muscle of LBP patients. Conclusions. 1. Ultrasonography of local and global muscles is an appropriate device for clinical diagnosis of LBP. 2. Strengthening TrA, MF, and GMed muscles for pain prevention is effective in the prevention and treatment of LBP.

Author(s):  
Ecenur Atli ◽  
Dilber Karagozoglu Coskunsu ◽  
Zeynep Turan ◽  
Ozden Ozyemisci Taskiran

Abstract Objective To examine the effect of neuromuscular electrical stimulation (NMES) combined with core stabilization exercises (CSE) in patients with chronic low back pain (CLBP). Methods Thirty-six patients (mean age 33.6±12.6 years) with CLBP were randomly assigned to 4 weeks (12 sessions) of NMES group (NMES combined with CSE) (n=18) vs. Control group (sham NMES and CSE) (n=18). After the 4 weeks, same exercises were given as home exercise program without NMES. The outcome measures were Oswestry Disability Index (ODI), Visual Analog Scale (VAS), Nottingham Health Profile (NHP) and ultrasonography. Ultrasonography was used for measuring transversus abdominis (TrA), internal oblique (IO), external oblique (EO) muscles thickness and lumbar multifidus muscle thickness and area. Assessments were performed at baseline and 4th week and eighth week follow-up. Results In both groups, the change of ODI, VAS and NHP values of the first measurement according to the values of the 4th week and the eighth week were found statistically significant (p=0.001; p<0.01). There were no statistically significant differences in ODI, VAS and NHP scores between the 4th week and the eighth week in both groups (p>0.05). None of NMES and control group measurements with US showed a statistically significant increase in the TrA, IO, EO thickness and multifidus thickness and area (p>0.05). Conclusions It was shown that NMES can be tolerated by patients with CLBP, but the addition of simultaneus NMES to CSE had no contribution to the clinical outcome measures.


Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 632
Author(s):  
Eleuterio A. Sánchez Romero ◽  
José Luis Alonso Pérez ◽  
Alberto Carlos Muñoz Fernández ◽  
Andrea Battaglino ◽  
Matteo Castaldo ◽  
...  

Purpose: The purpose of this study was to investigate the test-retest reliability of ultrasound (US) thickness measurements and the muscle contraction ratio (CR) of lumbar multifidus (LM) and transversus abdominis (TA) muscles in participants with and without nonspecific chronic low back pain (NCLBP). Methods: A total of 62 participants (37 with NCLBP, 25 without NCLBP) with participated in the study. The within-day and between-day reliability of US thickness measurements and CR in a lying (supine for TA and prone for LM) and sitting positions for both muscles (sitting on a gym ball with both feet on the ground or lifting one foot off the floor) were assessed. Reliability analysis was performed with intraclass correlations (ICCs) for these two static and dynamic positions. Results: Test-retest reliability was calculated to be good to high for the static position (ICC = 0.72–0.95) and the dynamic position (ICC = 0.74–0.94) sonographic measurements in both group of TA measurement. Test-retest reliability of LM measurements was good to high for the static position (ICC = 0.82–0.95) and the dynamic position (ICC = 0.85–0.97) sonographic measurements in both groups. Conclusions: US imaging is a highly reliable method for the assessment of TA and LM thickness muscles in the dynamic position in participants with and without NCLBP. The CR measures may be adequately reliable in assessing the function of the TA and LM muscles in participants with NCLBP and healthy ones.


2015 ◽  
Vol 25 (4) ◽  
pp. 1258-1265 ◽  
Author(s):  
Nicholas A. Cooper ◽  
Kelsey M. Scavo ◽  
Kyle J. Strickland ◽  
Natti Tipayamongkol ◽  
Jeffrey D. Nicholson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document