scholarly journals Using a real-time quantitative polymerase chain reaction (PCR) method for reliable enumeration of Aeromonas hydrophila in water samples

2013 ◽  
Vol 7 (19) ◽  
pp. 2119-2126
Author(s):  
Trakhna Faten ◽  
Maaroufi Abderrazak ◽  
Gadonna Widehem Pascale
2010 ◽  
Vol 134 (3) ◽  
pp. 444-448 ◽  
Author(s):  
Zhengming Gu ◽  
Jianmin Pan ◽  
Matthew J. Bankowski ◽  
Randall T. Hayden

Abstract Context.—BK virus infections among immunocompromised patients are associated with disease of the kidney or urinary bladder. High viral loads, determined by quantitative polymerase chain reaction (PCR), have been correlated with clinical disease. Objective.—To develop and evaluate a novel method for real-time PCR detection and quantification of BK virus using labeled primers. Design.—Patient specimens (n = 54) included 17 plasma, 12 whole blood, and 25 urine samples. DNA was extracted using the MagNA Pure LC Total Nucleic Acid Isolation Kit (Roche Applied Science, Indianapolis, Indiana); sample eluate was PCR-amplified using the labeled primer PCR method. Results were compared with those of a user-developed quantitative real-time PCR method (fluorescence resonance energy transfer probe hybridization). Results.—Labeled primer PCR detected less than 10 copies per reaction and showed quantitative linearity from 101 to 107 copies per reaction. Analytical specificity of labeled primer PCR was 100%. With clinical samples, labeled primer PCR demonstrated a trend toward improved sensitivity compared with the reference method. Quantitative assay comparison showed an R2 value of 0.96 between the 2 assays. Conclusions.—Real-time PCR using labeled primers is highly sensitive and specific for the quantitative detection of BK virus from a variety of clinical specimens. These data demonstrate the applicability of labeled primer PCR for quantitative viral detection and offer a simplified method that removes the need for separate oligonucleotide probes.


Blood ◽  
2002 ◽  
Vol 99 (12) ◽  
pp. 4618-4625 ◽  
Author(s):  
Mehdi Alizadeh ◽  
Marc Bernard ◽  
Bruno Danic ◽  
Charly Dauriac ◽  
Brigitte Birebent ◽  
...  

We have developed a real-time quantitative polymerase chain reaction (PCR) assay using TaqMan technology (Applied Biosystems, Foster City, CA) for monitoring donor cell engraftment in allogenic hematopoietic stem cell transplant recipients. For this purpose, we selected 19 specific sequence polymorphisms belonging to 11 human biallelic loci located on 9 different chromosomes. Using a set of specially designed primers and fluorogenic probes, we evaluated the 19 markers' informativity on a panel of 126 DNA samples from 63 recipient/donor pairs. In more than 90% of these pairs, discrimination between recipient and donor genetic profile was possible. By using serial dilutions of mixed DNAs, we evaluated the linearity and sensitivity of the method. A linear correlation with rhigher than 0.98 and a sensitivity of 0.1% proved reproducible. Fluorescent-based PCR of short tandem repeats (STR-PCR) and real-time PCR chimerism assay were compared with a panel of artificial cell mixtures. The main advantage of the real-time PCR method over STR-PCR chimerism assays is the absence of PCR competition and plateau biases, and results evidenced greater sensitivity and linearity with the real-time PCR method. Furthermore, different samples can be tested in the same PCR run with a final result in fewer than 48 hours. Finally, we prospectively analyzed patients who received allografts and present 4 different clinical situations that illustrate the informativity level of our method. In conclusion, this new assay provides an accurate quantitative assessment of mixed chimerism that can be useful in guiding early implementation of additional treatments in hematopoietic stem cell transplantation.


2020 ◽  
Vol 17 (1) ◽  
Author(s):  
Yang Zhang ◽  
Chunyang Dai ◽  
Huiyan Wang ◽  
Yong Gao ◽  
Tuantuan Li ◽  
...  

Abstract Background Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required. A previous study reported that one-step nested (OSN)-qRT-PCR revealed better suitability for detecting SARS-CoV-2. However, information on the analytical performance of OSN-qRT-PCR is insufficient. Method In this study, we aimed to analyze OSN-qRT-PCR by comparing it with droplet digital PCR (ddPCR) and qRT-PCR by using a dilution series of SARS-CoV-2 pseudoviral RNA and a quality assessment panel. The clinical performance of OSN-qRT-PCR was also validated and compared with ddPCR and qRT-PCR using specimens from COVID-19 patients. Result The limit of detection (copies/ml) of qRT-PCR, ddPCR, and OSN-qRT-PCR were 520.1 (95% CI: 363.23–1145.69) for ORF1ab and 528.1 (95% CI: 347.7–1248.7) for N, 401.8 (95% CI: 284.8–938.3) for ORF1ab and 336.8 (95% CI: 244.6–792.5) for N, and 194.74 (95% CI: 139.7–430.9) for ORF1ab and 189.1 (95% CI: 130.9–433.9) for N, respectively. Of the 34 clinical samples from COVID-19 patients, the positive rates of OSN-qRT-PCR, ddPCR, and qRT-PCR were 82.35% (28/34), 67.65% (23/34), and 58.82% (20/34), respectively. Conclusion In conclusion, the highly sensitive and specific OSN-qRT-PCR assay is superior to ddPCR and qRT-PCR assays, showing great potential as a technique for detection of SARS-CoV-2 in patients with low viral loads.


2002 ◽  
Vol 79 (4) ◽  
pp. 553-558 ◽  
Author(s):  
Rémi Alary ◽  
Arnaud Serin ◽  
Marie-Pierre Duviau ◽  
Philippe Jourdrier ◽  
Marie-Françoise Gautier

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Chai Fung Pui ◽  
Lesley Maurice Bilung ◽  
Kasing Apun ◽  
Lela Su’ut

Various prevalence studies onLeptospirain animals and humans, as well as environmental samples, had been conducted worldwide, including Malaysia. However, limited studies have been documented on the presence of pathogenic, intermediate, and saprophyticLeptospirain selected animals and environments. This study was therefore conducted to detectLeptospiraspp. in rats, soil, and water from urban areas of Sarawak using the polymerase chain reaction (PCR) method. A total of 107 rats, 292 soil samples, and 324 water samples were collected from April 2014 to February 2015. PathogenicLeptospirawas present in 5.6% (6/107) of rats, 11.6% (34/292) of soil samples, and 1.9% (6/324) of water samples. IntermediateLeptospirawas present in 2.7% (8/292) of soil samples and 1.9% (6/324) of water samples. SaprophyticLeptospirawas present in 10.3% (11/107) of rats, 1.4% (4/292) of soil samples, and 0.3% (1/324) of water samples. From this study, 76Leptospiraspp. were isolated. Based on DNA sequencing, the dominantLeptospiraspp. circulating in urban areas of Sarawak are pathogenicLeptospira noguchii, intermediateLeptospira wolffiiserovar Khorat, and saprophyticLeptospira meyeri, respectively. Overall, this study provided important surveillance data on the prevalence ofLeptospiraspp. from rats and the environment, with dominant local serovars in urban areas of Sarawak.


Sign in / Sign up

Export Citation Format

Share Document