scholarly journals Low Total Harmonic Distortion and High Power Factor in Parallel Active Power Filter

2019 ◽  
2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Ming-Hung Chen

This paper proposes a new adaptive filter for wind generators that combines instantaneous reactive power compensation technology and current prediction controller, and therefore this system is characterized by low harmonic distortion, high power factor, and small DC-link voltage variations during load disturbances. The performance of the system was first simulated using MATLAB/Simulink, and the possibility of an adaptive digital low-pass filter eliminating current harmonics was confirmed in steady and transient states. Subsequently, a digital signal processor was used to implement an active power filter. The experimental results indicate, that for the rated operation of 2 kVA, the system has a total harmonic distortion of current less than 5.0% and a power factor of 1.0 on the utility side. Thus, the transient performance of the adaptive filter is superior to the traditional digital low-pass filter and is more economical because of its short computation time compared with other types of adaptive filters.


Author(s):  
Chau Minh Thuyen ◽  
Truong Khac Tung ◽  
Nguyen Hoai Phong

<p>This paper proposes a new multi-objective optimization design method for Hybrid Active Power Filter based on the Vortex Search algorithm. The Vortex Search algorithm belongs to the Single-Solution Based algorithm class of Metaheuristics algorithm. This design method has the advantage of fast execution time, high convergence speed and prevent local trap problems. The achieved results are multi-objective, such as minimum total harmonic distortion of the supply current and source voltage and satisfy many constraints such as system stability, resonance conditions of branches and limits of the parameters. Compared with the traditional design method, simulation results have proved that: the proposed design method is given with better results in minimizing total harmonic distortion of the supply current and source voltage.</p>


Author(s):  
Dasari Vinay

In this paper we are going to see how the DSM PI controller is used to reduce the harmonics in faster. DSM PI controller steps up the voltage to required level. The main aim is to improve the total harmonic distortion. Keywords: Shunt active filter, hybrid active filters, DSM PI controller


2021 ◽  
Vol 226 (11) ◽  
pp. 30-37
Author(s):  
Phan Thanh Hiền ◽  
Nguyễn Hải Bình ◽  
Vũ Duy Hưng

Bộ lọc công suất tích cực kiểu song song (SAPF- Shunt Active Power Filter) thường được sử dụng để loại bỏ các thành phần sóng hài có hại cho mạng điện và thiết bị điện. Có hai nhóm thông số chính của SAPF nên được tối ưu hóa để có được hiệu suất tốt hơn và giảm tần số đóng cắt của IGBT. Nhóm đầu tiên là giá trị của tụ điện liên kết DC và cuộn cảm ghép nối. Nhóm thứ hai là các thông số của bộ điều khiển để kiểm soát tổn thất điện năng và dòng điện bù. Bài báo này trình bày giải pháp sử dụng Giải thuật di truyền (GA) để điều chỉnh các hệ số của bộ điều khiển PI và thu được các giá trị tối ưu của tụ điện và cuộn cảm của bộ lọc cùng một lúc. Phương pháp đề xuất được chứng minh thông qua mô phỏng trên Matlab/ Simulink. Kết quả, nhóm tác giả đã tìm được bộ tham số của bộ lọc công suất tích cực kiểu song song cho hệ số tổng méo sóng hài (THD- Total Harmonic Distortion) bằng 1,48% trong khi tần số chuyển mạch (fs) của IGBT chỉ là 50 kilohert. Do đó, các kết quả thu được góp phần ứng dụng vào các bộ lọc công suất tích cực nâng cao chất lượng điện năng.


Sign in / Sign up

Export Citation Format

Share Document