scholarly journals Underwater near-infrared spectroscopy can measure training adaptations in adolescent swimmers

PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e4393 ◽  
Author(s):  
Ben Jones ◽  
Dave Parry ◽  
Chris E. Cooper

The development of an underwater near-infrared spectroscopy (uNIRS) device has enabled previously unattainable measurements of peripheral muscle hemodynamics and oxygenation to be taken within the natural aquatic environment. The purposes of this study were (i) to trial the use of uNIRS, in a real world training study, and (ii) to monitor the effects of a swim training program upon muscle oxygenation status in short distance swimming. A total of 14 junior club level swimmers completed a repeated swim sprint test before and after an eight week endurance training program. A waterproof, portable Near-Infrared Spectroscopy device was attached to the vastus lateralis. uNIRS successfully measured changes in muscle oxygenation and blood volume in all individuals; rapid sub-second time resolution of the device was able to demonstrate muscle oxygenation changes during the characteristic swim movements. Post training heart rate recovery and swim performance time were significantly improved. uNIRS data also showed significant changes. A larger rise in deoxyhemoglobin during individual sprints suggested training induced an increase in muscle oxygen extraction; a faster recovery time for muscle oxygenation suggested positive training induced changes and significant changes in muscle blood flow also occur. As a strong correlation was seen between an increased reoxygenation rate and an improved swim performance time, these findings support the use of uNIRS as a new performance analysis tool in swimming.

1999 ◽  
Vol 24 (3) ◽  
pp. 216-230 ◽  
Author(s):  
Andrew Hicks ◽  
Stuart Mcgill ◽  
Richard L. Hughson

The relationship between tissue oxygenation measured by near-infrared spectroscopy (NIRS) and forearm muscle blood flow (FBF) measured by Doppler ultrasound was tested during isometric contractions at 10 and 30% maximal voluntary contraction (MVC) under conditions of normoxia and hypoxia (14% inspired O2). Six subjects maintained contractions at 10% MVCfor 5 min and at 30% for 2 min in both gas conditions. FBF was elevated during exercise at 10% MVC in hypoxia compared to normoxia, but there was no further increase in flow at 30% MVC. Median power frequency calculations from electromyographic recordings suggested progressive development of fatigue throughout both 10 and 30% MVC contractions. NIRS indicated no change in muscle oxygenation at 10% MVC, but deep venous blood O2 saturation was reduced in normoxia and more so in hypoxia. At 30% MVC, both NIRS and venous O2 saturation were reduced, with no effect of hypoxia on the NIRS signal. While NIRS might provide an indication of muscle oxygenation during isometric exercise, the conflicting findings for NIRS and direct venous blood sampling at 10 vs. 30% MVC suggest caution in the application of this noninvasive technique. Key words: exercise, Doppler ultrasound, venous blood. O2 saturation, hemoglobin


2020 ◽  
Vol 41 (7) ◽  
pp. 075003
Author(s):  
Christina Wolfsberger ◽  
Nariae Baik-Schneditz ◽  
Bernhard Schwaberger ◽  
Corinna Binder-Heschl ◽  
Höller Nina ◽  
...  

2006 ◽  
Vol 31 (1) ◽  
pp. 48-55 ◽  
Author(s):  
Kotaro Kawaguchi ◽  
Yukiko Hayashi ◽  
Kiyokazu Sekikawa ◽  
Mitsuru Tabusadani ◽  
Tsutomu Inamizu ◽  
...  

This study examined the relationship between acute cardiorespiratory and muscle oxygenation and blood volume changes during prolonged exercise. Eight healthy male volunteers (mean maximum oxygen uptake ([Formula: see text]O2max) = 41.6 ± 2.4 mL/kg/min) performed 60 min submaximal cycling at 50% [Formula: see text]O2max. Oxygen uptake ([Formula: see text]O2) was measured by indirect spirometry, cardiac output (CO) was estimated using a PortapresTM, and right vastus lateralis oxyhemoglobin/ myoglobin (oxyHb/Mb), deoxyhemoglobin/myoglobin (deoxyHb/Mb), and total hemoglobin/myoglobin (total Hb/Mb) were recorded using near-infrared spectroscopy (NIRS). After 40 min of exercise, there was a significant increase in [Formula: see text]O2 due to a significantly higher arteriovenous oxygen difference ((a - v)O2diff). After 30 min of exercise CO remained unchanged, but there was a significant decrease in stroke volume and a proportionate increase in heart rate, thus indicating the occurrence of cardiovascular drift. During the first few minutes of exercise, there was a decline in oxyHb/Mb and total Hb/Mb, whereas deoxyHb/Mb remained unchanged. Thereafter, oxyHb/Mb and total Hb/Mb increased systematically until the termination of exercise while deoxyHb/Mb declined. After 40 min of exercise, these changes were significantly different from the baseline values. There were no significant correlations between the changes in the NIRS variables and systemic [Formula: see text]O2 or mixed (a - v)O2diff during exercise. These results suggest that factors other than localized changes in muscle oxygenation and blood volume account for the increased [Formula: see text]O2 during prolonged submaximal exercise. Key words: near infrared spectroscopy, cardiovascular drift, systemic oxygen consumption.


2019 ◽  
Vol 12 (3) ◽  
Author(s):  
Yi‐Hua Huang ◽  
Ming‐Lung Chuang ◽  
Pay‐Zen Wang ◽  
Yueh‐Chi Chen ◽  
Chung‐Ming Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document