scholarly journals Multimode ultrasonic technique is recommended for the differential diagnosis of thyroid cancer

PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9112
Author(s):  
Juan Wang ◽  
Xin He ◽  
Li Ma ◽  
Miao Li ◽  
Lei Sun ◽  
...  

Background B-mode ultrasound is one of the most commonly used imaging techniques for evaluating thyroid nodules due to its noninvasive property and excellent performance in terms of discriminating between benign and malignant nodules. However, the accuracy of differential diagnosis strongly depends on the experience of ultrasonographers. In addition to B-mode ultrasound, the elastic mode and contrast-enhanced mode have shown complimentary value in the diagnosis of thyroid nodules. The combination of multiple modes in ultrasonic techniques may effectively undermine diagnostic subjectiveness and improve accuracy. In this study, we evaluated the diagnostic value of combining the three ultrasonic modes for differentiating thyroid cancers. Methods In this retrospective study, we analyzed a total of 196 thyroid nodules with suspected malignancies from 185 patients who gave informed consent. Xi’an Jiaotong University granted ethical approval (No. 2018200) to carry out the study within its facilities. All the patients received ultrasonic examinations with the B mode, elastic mode and contrast-enhanced mode, followed by histopathological confirmation by fine-need aspiration or surgery. A predictive multivariate logistic regression model was selected to integrate the variety of data obtained from the three modes. Results The combination of three ultrasonic techniques for differentiating malignant from benign thyroid nodules showed the highest diagnostic accuracy of 0.985 compared to the B mode alone (0.841) and the two-mode combination. The accuracy of the B mode combined with the elastic technique was 0.954, and the accuracy of the B mode combined with the contrast-enhanced technique was 0.960. Discussion Multimode ultrasonic techniques should be recommended to patients with suspected malignant thyroid nodules in routine clinical practice.


Author(s):  
Pēteris Priedītis ◽  
Maija Radziņa ◽  
Ilze Štrumfa ◽  
Zenons Narbuts ◽  
Arturs Ozoliņs ◽  
...  

Abstract The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS) in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign), underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC) were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule) and type of TIC curve rs = 0.38 (p = 0.021), as well as between mode of contrast enhancement rs = 0.39 (p = 0.022) and wash-out pattern rs =0.39 (p = 0.024). The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.





2019 ◽  
Vol 9 (2) ◽  
pp. 334-338
Author(s):  
Qing Yang ◽  
Wenhong Zhou ◽  
Jiyu Li ◽  
Guojun Wu ◽  
Feng Ding ◽  
...  

Objective: To compare the diagnostic value of shear wave elastography (SWE) and real-time elastography (RTE) in the diagnosis of benign and malignant thyroid nodules. Methods: A total of 34 patients who ever received thyroidectomy in our hospital from January 2016 to January 2018 were identified. Meanwhile, all the patients received SWE and RTE before surgery, and all the diagnoses were confirmed by pathological examinations. With respect to SWE technique, the Subject Operating Characteristics (ROC) curves were drawn, in order to obtain the optimal threshold and then make differential diagnoses of benign and malignant thyroid nodules. In terms of RTE, the Rago 5 scoring method was utilized to make differential diagnoses of benign and malignant thyroid nodules. Besides, the pathological examinations after surgery could be considered as the golden standard. At last, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE and RTE were calculated, respectively. Results: A total of 51 thyroid nodules were identified, and 41 nodules were benign, 10 nodules were malignant. On the basis of ROC curves, with respect to SWE, the best threshold for differential diagnosis of benign and malignant thyroid nodules is 38.3 kPa. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE were 72.7% (8/11), 85% (34/40), 82.4% (42/51), 68.4% (13/19), and 87.5% (35/40), respectively. And the diagnostic indicators of RTE were 81.8% (9/11), 87.5% (35/40), 84.3% (43/51), 73.7% (14/19), and 90.0% (36/40). The sensitivity of quasi-static elastography in differential diagnosis of benign and malignant thyroid nodules with diameter ≤1 cm was 87.5% (7/8), and the sensitivity of SWE was 50.0% (5/10). In addition, the accuracy of SWE in differential diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm was 100% (6/6), and the accuracy of RTE for this kind of thyroid nodules was 66.7% (4/6). Conclusion: Both SWE and RTE technology have good application value in differential diagnosis of benign and malignant thyroid nodules. But, SWE is preferable when making diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm, and RTE was superior in detecting benign and malignant thyroid nodules with diameter ≤1 cm.



2015 ◽  
Vol 31 (3) ◽  
pp. 138-144 ◽  
Author(s):  
Jue Jiang ◽  
Xu Shang ◽  
Hua Wang ◽  
Yong-Bo Xu ◽  
Ya Gao ◽  
...  


Endocrine ◽  
2016 ◽  
Vol 53 (2) ◽  
pp. 480-488 ◽  
Author(s):  
Qiong Wu ◽  
Yan Wang ◽  
Yi Li ◽  
Bing Hu ◽  
Zhi-Yan He




Author(s):  
Yunlin Huang ◽  
Yurong Hong ◽  
Wen Xu ◽  
Kai Song ◽  
Pintong Huang

Abstract Objectives To evaluate the diagnostic performance of the American College of Radiology (ACR) Thyroid Image Reporting and Data System (TI-RADS), contrast-enhanced ultrasound (CEUS), and a modified TI-RADS in differentiating benign and malignant nodules located in the isthmus. Methods This retrospective study was approved by the institutional review board. Informed consent was obtained. Grayscale ultrasound (US) and CEUS images were obtained for 203 isthmic thyroid nodules (46 benign and 157 malignant) in 198 consecutive patients (156 women, mean age: 44.7 years ± 11.3 [standard deviation]; 47 men, mean age: 40.9 years ± 11.0). The area under the receiver operating characteristic curve (AUC) of the diagnostic performance of the ACR TI-RADS, CEUS, and the modified TI-RADS were evaluated. Results Lobulated or irregular margins (P = 0.001; odds ratio [OR] = 9.250) and punctate echogenic foci (P = 0.007; OR = 4.718) on US and hypoenhancement (P < 0.001; OR = 20.888) on CEUS displayed a significant association with malignancy located in the isthmus. The most valuable method to distinguish benign nodules from malignant nodules was the modified TI-RADS (AUC: 0.863 with modified TR5), which was significantly better than the ACR TI-RADS (AUC: 0.738 with ACR TR5) (P < 0.001) but showed no significant difference with respect to CEUS (AUC: 0.835 with hypoenhancement) (P = 0.205). The diagnostic value was significantly different between CEUS and the ACR TI-RADS (P = 0.028). Conclusion The modified TI-RADS could significantly improve the accuracy of the diagnosis of thyroid nodules located in the isthmus.



Sign in / Sign up

Export Citation Format

Share Document