scholarly journals Development and Validation of Ultraviolet and Reverse Phase-high Performance Liquid Chromatographic Method for Estimation of Cilnidipine

Author(s):  
Biswajit Samantaray ◽  
Jagannath Panda ◽  
Satyapriya Mahapatra ◽  
Kajal Ray ◽  
Satish Kanhar

Aim: The current experiment was to develop and validate a straight forward RP-HPLC methodology for the determination of Cilnidipine. Methodology: UV spectroscopy was used to estimate Cilnidipine. Action separation of Cilnidipine was achieved by employing a C18 column. Mobile phase combination of methanol: water (90:10 v/v) was tense at the flow of 1 ml/min. Detection was performed at 241 nm. Validation parameters were evaluated in line with the International conference on harmonization (ICH) Q2R1 guidelines. Results: The standardization curve was linear within the varying concentration of 2-10 mg/ml for Cilnidipine with parametric statistic (r2) equal to 0.999. The tactic was found to be accurate (101.66% recovery), precise (intraday, 1.65 and inter day, 1.38) and robust (% RSD was calculated to be 0.66, 0.58 and 0.81 for variation in mobile phase composition, wave length and flow velocity respectively) for the analysis of Cilnidipine. Conclusion: The developed method has passed all the validation tests and can be successfully applied to estimate the presence of Cilnidipine in bulk as well as in pharmaceutical formulations.

Author(s):  
Kuntal Mukherjee ◽  
S. T. Narenderan ◽  
B. Babu ◽  
Survi Mishra ◽  
S. N. Meyyanathan

A simple, sensitive and rapid high performance liquid chromatographic method has been developed for the determination of Propofol. The main focus of the method was to determine Propofol in solution form as well as in marketed formulation. Chromatographic separation was achieved on Inertsil ODS-3V column (250mm x 4.6mm; 5µm) with a mobile phase consisting of methanol: water (85:15), with a flow rate of 1.0ml/min (UV detection at 270nm). Linearity was observed over the concentration range of 10-110µg/ml with a regression equation y=88048x + 44524 and having a regression value (R2) of 0.999. The LOD and LOQ values found to be 10ng and 100ng, respectively. No changes found in ruggedness and robustness studies. The percentage of recovery was found to be 95.25% to 101.81%. Validation studies revealed that the method was specific, accurate, precise, reliable, robust, reproducible and suitable for the quantitative analysis in its pharmaceutical formulations.


2012 ◽  
Vol 1 (8) ◽  
pp. 193-198 ◽  
Author(s):  
Chusena Narasimharaju Bhimanadhuni ◽  
Devala Rao Garikapati ◽  
Pasupuleti Usha

A Simple, efficient and reproducible reverse phase high performance liquid chromatographic method was developed and validated for the Simultaneous determination of Escitalopram oxalate and Clonazepam in combined dosage form. The separation was effected on a Hypersil ODS C18 column (250mm X 4.6mm; 5µ) using a mobile phase mixture of buffer and acetonitrile in a ratio of 50:50 v/v at a flow rate of 1.0ml/min. The detection was made at 240nm. The retention time of Escitalopram oxalate and Clonazepam was found to be 2.840± 0.007min and 4.007±0.006 min. Calibration curve was linear over the concentration range of 20-120µg/ml and 1-6µg/ml for Escitalopram oxalate and Clonazepam. All the analytical validation parameters were determined and found in the limit as per ICH guidelines, which indicates the validity of the method. The developed method is also found to be precise, accurate, specific, robust and rapid for the simultaneous determination of Escitalopram oxalate and Clonazepam in tablet dosage forms.DOI: http://dx.doi.org/10.3329/icpj.v1i8.11249 International Current Pharmaceutical Journal 2012, 1(8): 193-198 


2021 ◽  
Vol 37 (02) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


2019 ◽  
Vol 9 (01) ◽  
pp. 83-88
Author(s):  
Pinkal Patel ◽  
Nalini Patel ◽  
Kinjal Parmar

A simple, selective and rapid reversed phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed and validated for the simultaneous analysis Gatifloxacin and flurbiprofen sodium in eye drops. The separation was carried out using a mobile phase consisting ACN: Buffer (pH 3.5) in the ratio of 55:45 v/v. The column used was Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with flow rate of 1 ml / min using UV detection at 268 nm. The described method was linear over a concentration range of 2-12 μg/ml for both of Gatifloxacin and flurbiprofen sodium. The retention times of Gatifloxacin and flurbiprofen sodium were found to be 3.710 min. and 6.797 min respectively. Method was validated statistically and recovery studies were carried out. The proposed method has been applied successfully to the analysis of cited drugs either in pure form or in pharmaceutical formulations with good accuracy and precision. The method here in described can be employed for quality control and routine analysis of drugs in pharmaceutical formulations.


Author(s):  
Abrar Ahmed ◽  
Tayyaba Mahtab ◽  
Sumaiyya Saleem

Midostaurin is a multi-targeted protein kinase inhibitor that has been used for the treatment of acute myeloid leukemia.  Here, a rapid and precise reverse phase high-performance liquid chromatographic method has been developed for the validation of midostaurin, in its API form as well as in capsule dosage form. Chromatography was carried out on a X-Bridge C18 (4.6 x 250 mm, 5 µm) column using a mixture of methanol: water (75:25% v/v) as the mobile phase at a flow rate of 1.0 mL/min, the detection was carried out at 243nm and the retention time of the midostaurin was found to be 3.155. The method produce linear responses in the concentration range of 10-50 µg/mL of midostaurin. The method precision for the determination of assay was below 2.0 % RSD. The LOD and LOQ values obtained were 1.2 µg/mL and 3.8 µg/mL respectively. There were no significant changes observed upon changing chromatographic conditions indicating the method to be robust. Therefore this validated method can be useful in the quality control of bulk and pharmaceutical formulations of midostaurin. 


2010 ◽  
Vol 7 (2) ◽  
pp. 600-604 ◽  
Author(s):  
A. Lakshmana Rao ◽  
V. Naga Jahnavi

A rapid and sensitive high performance liquid chromatographic method was developed for the estimation of levetiracetam in bulk and pharmaceutical formulations. Levetiracetam was chromatographed on a reverse phase C18column in a mobile phase consisting of 0.05 M KH2PO4buffer (pH 3.0 adjusted with orthophosphoric acid) and methanol in the ratio 70:30 v/v. The mobile phase was pumped at a flow rate of 1.2 mL/min. with detection at 210 nm. The detector response was linear in the concentration of 20-120 μg/mL. The limit of detection and limit of quantification was found to be 0.0104 and 0.0317 μg/mL, respectively. The intra and inter day variation was found to be less than 1%. The mean recovery of the drug from the solution containing 100 µg/mL was 100.038 μg/mL. The proposed method is simple, fast, accurate, precise and reproducible hence can be applied for routine quality control analysis of levetiracetam in bulk and pharmaceutical formulations.


Author(s):  
E. Amulya ◽  
N. Naveen Kumar ◽  
CH. Mounika ◽  
V. Kowmudi ◽  
N. Supriya ◽  
...  

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Trihexyphenidyl and Haloperidol, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Altima C18 (4.6 x 150mm, 5μm) column using a mixture of Methanol: TEA Buffer pH 4.5: Acetonitrile (50:25:25) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 225 nm. The retention time of the Trihexyphenidyl and Haloperidol was 2.102, 3.537±0.02min respectively. The method produce linear responses in the concentration range of 15-75ppm of Trihexyphenidyland 37.5-187.5ppm of Haloperidol. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of pharmaceutical formulations.


2005 ◽  
Vol 70 (12) ◽  
pp. 1451-1460 ◽  
Author(s):  
Dragica Zendelovska ◽  
Trajce Stafilov

Ahigh-performance liquid chromatographicmethod for the determination of ofloxacin and lomefloxacin in human plasma has been developed and validated. The effect of organic modifiers on the retention of the investigated drugs was investigated. A simple isocratic chromatographic assay with UV-detection at 280nm was performed on a Hibar Lichrospher 100 RP 8 column (250x4.6mm 5?m. Merck, Germany) using a mixture of acetonitrile and 0.5 % triethylamine in water (pH adjusted to 2.5 with H3PO4) (15:85, V/V) as the mobile phase at flow rate of 1.2 mL min-1. The calibration curves were linear in the concentration ragne of 0.5-6.0?g mL-1 for ofloxacin and 0.2-4.5 ?g mL-1 for lomefloxacin.


2021 ◽  
Vol 37 (2) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.