scholarly journals Spectroscopic Estimation of Doxylamine Succinate in Tablets and Human Plasma by Formation of Ion-pair Complex

Author(s):  
Narender Malothu ◽  
Sowjanya Ravuri ◽  
Balakrishna Muthyala ◽  
Narayana Rao Alla ◽  
Anka Rao Areti

Aim: To develop a simple spectroscopic method for estimation of doxylamine (DOX) succinate in its tablet dosage form and human plasma with the aid of an ion-pair complex formation. Methods: In this method, methyl orange (0.05 % w/v) dye was used to form an ion-pair complex in acetate buffer (1M; pH: 5.00) at 300 C ± 20C. The ion-pair complex formed was extracted with chloroform. The maximum absorbance for the ion-pair complex was measured at 420 nm. Results and discussion: The method conditions were obeyed Beer's law in the concentrations ranging from 5-25 µg/mL of DOX succinate with a correlation coefficient (r2) of 0.992. The ion-pair (drug-dye) complex was formed in a 1:1 ratio which was demonstrated by Jobs' method of continuous variation. The method was satisfied the validation criteria as per ICH (Q2R1) guidelines. Accuracy studies showed 99.06-100.9 % recovery of the analyte. The responses of the precision and robustness were found within acceptable limits (<2% RSD). The LOD and LOQ values were found as 0.31 and 0.939 µg/mL, respectively. Conclusion: The developed method was simple, specific, and economical and requires a short analysis time. Therefore it could be considered for precise analysis of DOX succinate in biological matrices.

2018 ◽  
Vol 8 (4) ◽  
pp. 537-551 ◽  
Author(s):  
Jui J. Pandya ◽  
Mallika Sanyal ◽  
Priyanka A. Shah ◽  
Pranav S. Shrivastav

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (11) ◽  
pp. 53-59
Author(s):  
Tukaram M. Kalyankar ◽  
◽  
Shital S. Dange ◽  
Shivraj B. Hambarde ◽  
Shailesh J. Wadher ◽  
...  

A simple, accurate and precise UV spectrometric method has been developed for the simultaneous determination of valsartan and hydrochlorothiazide in tablet dosage form. Spectra of valsartan and hydrochlorothiazide in methanol and water (50:50 V/V) show λ max at 250.0 nm and 271.4 nm, respectively. Valsartan and hydrochlorothiazide are subjected to various stress conditions like acid, alkali, thermal and photolytic degradation. Beer’s law was obeyed in concentration range of 4- 24 µg mL-1 for valsartan and 0.5-3 µg mL-1 for hydrochlorothiazide at their respective wavelengths. The proposed method was successfully applied to tablet dosage form for determination of both drugs. The percentage recovery of valsartan and hydrochlorothiazide were found to be 100.19 % and 99.51 %, respectively. A novel accurate and precise stability indicating spectroscopic method has been developed for estimation of valsartan and hydrochlorothiazide.


Author(s):  
ALEKHYA B. ◽  
M. SINDHUSHA ◽  
SORAJ K. RAUL ◽  
GOPAL K. PADHY

Objective: The objective of the present work is to develop and validate a new UV derivative spectrophotometric method for simultaneous estimation of metoprolol succinate and ramipril in methanol: water (50:50v/v). Methods: “Zero crossing technique” was chosen for quantitative determination. The zero-crossing points (ZCP’s) were found to be 209 nm where metoprolol succinate was quantified and 211 nm where ramipril was quantified. This method was then subjected to accuracy, linearity, sensitivity and reproducibility according to ICH guidelines to ensure and confirm its validity. Results: The method was found to be obeying Beer’s law in the range of 10-50 µg/ml and 5-25 µg/ml for metoprolol succinate and ramipril, respectively. The % recoveries were observed between the range of 99.2-100.2 for metoprolol succinate and 99.57-99.86 for ramipril. The intra-day and inter-day results showed reproducibility. Conclusion: It can be concluded that the developed third-order UV derivative spectroscopic method for the simultaneous determination of metoprolol succinate and ramiprilcan be recommended for routine quantitative analysis.


2019 ◽  
Vol 9 (6) ◽  
pp. 233-241
Author(s):  
Swapnil R. Patil ◽  
Anagha P. Patil ◽  
Prajakta D. Chaudhari ◽  
Kalpesh V. Sonar

Author(s):  
Sunil More ◽  
Ashpak Tamboli ◽  
Snehal Patil ◽  
Amol Vhanmane

There is not a single analytical methods appeared in the literature for combined estimation of Amlodipine and Chlorthalidone in tablets dosage form. Attempts were made to develop a simple, precise and accurate Simultaneous UV spectroscopic method of Amlodipine and Chlorthalidone in bulk and Amlodac CH tablet dosage form by using simultaneous equation method. UV spectrophotometric method was developed and validated as per ICH guidelines using methanol as mobile phase. Amlodipine and Chlorthalidone individually follows the Beer-Lamberts law over concentration range 2.5-12.5μg/ml and 6.25-31.5μg/ml, Regression of coefficient was found to be r2=0.999 and r2=0.999 respectively. The percentage recovery was found in the range of 98% to 102% at three different levels. The proposed method was successfully applied for the determination of Amlodipine and Chlorthalidone in tablets dosage form as per ICH guidelines the result of the analysis were validated statistically and were found to be satisfactory.


Author(s):  
VAIBHAV S KHODKE ◽  
GAME MD

Objective: The objective of the present study is to develop ultraviolet (UV)-spectroscopic method using pure drug and tablet dosage form that consistently produces a drug with a minimal variation that adheres to quality criteria of purity, identity, and potency. Methods: UV-spectrophotometric method has been developed using a solvent composed of methanol:water (30:70) as a diluent to determine the dalfampridine (DFP) content in bulk and pharmaceutical dosage form at predetermined λmax of 262 nm. Results: It was proved linear in the range of 02–12 μg/ml and exhibited a good correlation coefficient (r2 = 0.9915) and excellent mean recovery (0.004136347%). This method was successfully applied to the determination of DFP content of marketed tablet Dalstep 10 mg (Sun Pharmaceutical Pvt. Ltd.,) from India; the results were in good agreement with the label claims. Conclusion: The method proved to be simple, accurate, precise, specific, robust, and less time consuming and can be applied for the determination of DFP in bulk and marketed formulation.


Sign in / Sign up

Export Citation Format

Share Document