scholarly journals A Review on the Safety of One-Stage Circumferential Ring Constriction Release

2015 ◽  
Vol 100 (2) ◽  
pp. 341-349 ◽  
Author(s):  
Theddeus O.H. Prasetyono ◽  
Ade S.N. Sitorus

The study was undertaken to investigate the use of one-stage circumferential ring-constriction release with Z-plasties regarding the safety, aesthetic appearance, and limb function. A thorough review was conducted on all English publications in PubMed during the period of 2001 through 2011. Titles and abstracts were identified using online search engine from National Library of Medicine's PubMed database under the keywords “limb constriction ring,” “limb constriction band,” “amniotic band,” “annular constriction,” and “circumferential constriction.” We used Boolean operator and field of title. Evaluation was done to search indications, timing of the first surgical intervention, time interval between surgeries, patients' gender, anatomic location of the ring, wound healing problems, and scar quality. Fourteen publications met the criteria. There were 17 patients with 25 ring constrictions in total. Sixteen ring constrictions (64%) were circumferential; nine (36%) were semi-circumferential. Mean age of 14 patients treated with one-stage release was 4.8 years. Six articles mentioned about normal development of postoperative limb function. Mean age of three patients treated with staged release was 10.5 months. Two articles mentioned regained distal muscle function postoperatively. It is confirmed that surgeons may continue the practice to release circumferential CRS in one stage.

2020 ◽  
Vol 106 (7) ◽  
pp. 1353-1359
Author(s):  
Benjamin Dufournier ◽  
Stéphane Guero ◽  
Marine de Tienda ◽  
Caroline Dana ◽  
Nicolas Garcelon ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Tarek M. Owaidah ◽  
Hazzaa A. Alzahrani ◽  
Nouf S. Al-Numair ◽  
Abdulmjeed O. Alnosair ◽  
Amelita M. Aguilos ◽  
...  

Background. The one-stage assay is the most common method to measure factor VIII activity (FVIII : C) in hemophilia A patients. The chromogenic assay is another two-stage test involving purified coagulation factors followed by factor Xa-specific chromogenic substrate. Aim. This study aimed to assess the discrepancy and correlation between the chromogenic and one-stage assays in measuring FVIII : C levels in hemophilia patients receiving Extended Half-Life Elocta® as a recombinant extended half-life coagulation factor. Methods. We performed a study comparing the measurements of FVIII : C levels by the chromogenic versus the one-stage assays at different drug levels. Data of FVIII : C levels, dosage, and the time interval from administration to measurement were retrieved from the hospital records. The correlation, mean differences, and discrepancy between the two assays were calculated. The linear regression analysis was used to predict the time interval till reaching 1% FVIII : C. Results. Fourteen patients with 56 samples were included in the study. Of them, 13 patients were receiving Elocta® as a prophylactic, while one was receiving Elocta® on demand. One-third of these samples showed a discrepancy between the chromogenic and one-stage assays. The two assays were well correlated. Mean differences were significant at the individual and the time interval level. The time since the last Elocta® injection could significantly predict FVIII : C levels (β = 0.366, P<0.001). Conclusion. Our findings suggested a significant difference between both methods; the FVIII : C levels measured by the one-stage assay were less than those estimated by the chromogenic assay. However, the measurements of FVIII levels by the two assays were well correlated but discrepant in one-third of the samples. The levels of FVIII : C reach 1% after 5.4 days since the last Elocta® administration.


2007 ◽  
Vol 20 (03) ◽  
pp. 231-235 ◽  
Author(s):  
K. A. Johnson ◽  
B. E. Hildreth

SummaryForelimb deformity caused by radial agenesis was diagnosed in a one-year-old Shih Tzu dog. In contrast to most of the previously reported cases of radial agenesis, the humeroulnar joint was inherently stable. The deformity was treated by means of a one-stage ulnocarpal arthrodesis with the application of an eight hole dorsolateral arthrodesis bone plate and autogenous corticocancellous bone graft from the ilial wing. Radiographic evaluation at the eighth and sixteenth post-operative week showed evidence of union of the arthrodesis. At sixteen weeks post-operatively, the dog had much improved limb function. In humans afflicted with radial agenesis, ulnocarpal arthrodesis is used to restore forearm function by minimizing pain and decreasing the magnitude of angular deformity and instability at the level of the ulnocarpal joint. However, to our knowledge, this is the first report of treatment of radial agenesis in the dog by means of a one-stage, ulnocarpal arthrodesis.


2021 ◽  
Vol 103-B (11) ◽  
pp. 1678-1685
Author(s):  
Hussein Abdelaziz ◽  
Michael Schröder ◽  
Calvin Shum Tien ◽  
Kahled Ibrahim ◽  
Thorsten Gehrke ◽  
...  

Aims One-stage revision hip arthroplasty for periprosthetic joint infection (PJI) has several advantages; however, resection of the proximal femur might be necessary to achieve higher success rates. We investigated the risk factors for resection and re-revisions, and assessed complications and subsequent re-revisions. Methods In this single-centre, case-control study, 57 patients who underwent one-stage revision arthroplasty for PJI of the hip and required resection of the proximal femur between 2009 and 2018 were identified. The control group consisted of 57 patients undergoing one-stage revision without bony resection. Logistic regression analysis was performed to identify any correlation with resection and the risk factors for re-revisions. Rates of all-causes re-revision, reinfection, and instability were compared between groups. Results Patients who required resection of the proximal femur were found to have a higher all-cause re-revision rate (29.8% vs 10.5%; p = 0.018), largely due to reinfection (15.8% vs 0%; p = 0.003), and dislocation (8.8% vs 10.5%; p = 0.762), and showed higher rate of in-hospital wound haematoma requiring aspiration or evacuation (p = 0.013), and wound revision (p = 0.008). The use of of dual mobility components/constrained liner in the resection group was higher than that of controls (94.7% vs 36.8%; p < 0.001). The presence and removal of additional metal hardware (odds ratio (OR) = 7.2), a sinus tract (OR 4), ten years’ time interval between primary implantation and index infection (OR 3.3), and previous hip revision (OR 1.4) increased the risk of proximal femoral resection. A sinus tract (OR 9.2) and postoperative dislocation (OR 281.4) were associated with increased risk of subsequent re-revisions. Conclusion Proximal femoral resection during one-stage revision hip arthroplasty for PJI may be required to reduce the risk of of recurrent or further infection. Patients with additional metalware needing removal or transcortical sinus tracts and chronic osteomyelitis are particularly at higher risk of needing proximal femoral excision. However, radical resection is associated with higher surgical complications and increased re-revision rates. The use of constrained acetabular liners and dual mobility components maintained an acceptable dislocation rate. These results, including identified risk factors, may aid in preoperative planning, patient consultation and consent, and intraoperative decision-making. Cite this article: Bone Joint J 2021;103-B(11):1678–1685.


2020 ◽  
Vol 48 (9) ◽  
pp. 030006052094975
Author(s):  
Tian He ◽  
Hao Xu ◽  
Ping Sui ◽  
Xin Wang ◽  
Yujie Sun

Amniotic band syndrome is an unusual congenital condition characterized by manifestations of disfigurement and disablement. Patients with this condition may experience an array of clinical deformities, including constriction rings, digital defects, and even visceral defects. Although this disease has been identified for centuries, its etiology is still unknown. The present male patient was born by cesarean section at 34 weeks and 4 days of gestation. At birth, an amniotic band that encircled and constricted his right upper limb was observed. Four hours after the amniotic band was cut off, amputation was performed because the right limb remained insensate. The patient suffered from amniotic band syndrome and presented with a gangrenous limb leading to amputation at birth, which is extremely rare. Moreover, the patient’s mother suffered from a uterine septum, which has not been previously reported in this situation. Timely surgical treatment avoided further tissue necrosis threating the patient’s life. This rare case of amniotic band syndrome provides new clinical evidence for the “extrinsic theory”.


2017 ◽  
Vol 07 (02) ◽  
pp. e74-e78 ◽  
Author(s):  
A. Chon ◽  
B. Chen ◽  
W. Burkhalter ◽  
R.H. Chmait ◽  
M. Abdel-Sattar

AbstractWe report a case of amniotic band syndrome complicated by constriction bands and marked distal swelling of both lower extremities. Color Doppler interrogation of the right lower extremity revealed complete lack of blood flow below the level of the constriction. Upon fetoscopic survey, the right lower extremity beyond the constriction band appeared dusky red and discolored with desquamation, consistent with a necrotic appearance. The constriction bands were cut in utero using endoshears, thereby allowing restoration of blood flow on postoperative day 1. The patient was counseled extensively regarding the possibility of limb dysfunction or amputation. However, the baby was born with functional lower extremities, and at 21 months of age, the child was cruising and jumping on his own. This case demonstrates that there is unique plasticity in fetal limb recovery after a severe ischemic injury that is not otherwise seen in postnatal life. Reperfusion of the necrotic-appearing limb resulted in restoration of appearance and function without apparent deleterious effects on the fetus. We believe the favorable outcome in this case was likely due to timeliness of the in utero lysis of amniotic bands and the plasticity of fetal healing.


2004 ◽  
Vol 24 (3) ◽  
pp. 198-201 ◽  
Author(s):  
L. Sentilhes ◽  
E. Verspyck ◽  
D. Eurin ◽  
V. Ickowicz ◽  
S. Patrier ◽  
...  

2021 ◽  
Vol 11 (7) ◽  
pp. 94
Author(s):  
Ángela Milán-Tomás ◽  
Marta Fernández-Matarrubia ◽  
María Cruz Rodríguez-Oroz

Lewy body dementias (LBDs) consist of dementia with Lewy bodies (DLB) and Parkinson’s disease dementia (PDD), which are clinically similar syndromes that share neuropathological findings with widespread cortical Lewy body deposition, often with a variable degree of concomitant Alzheimer pathology. The objective of this article is to provide an overview of the neuropathological and clinical features, current diagnostic criteria, biomarkers, and management of LBD. Literature research was performed using the PubMed database, and the most pertinent articles were read and are discussed in this paper. The diagnostic criteria for DLB have recently been updated, with the addition of indicative and supportive biomarker information. The time interval of dementia onset relative to parkinsonism remains the major distinction between DLB and PDD, underpinning controversy about whether they are the same illness in a different spectrum of the disease or two separate neurodegenerative disorders. The treatment for LBD is only symptomatic, but the expected progression and prognosis differ between the two entities. Diagnosis in prodromal stages should be of the utmost importance, because implementing early treatment might change the course of the illness if disease-modifying therapies are developed in the future. Thus, the identification of novel biomarkers constitutes an area of active research, with a special focus on α-synuclein markers.


Sign in / Sign up

Export Citation Format

Share Document