RSC Advances ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 297-308
Author(s):  
Zhi Chen ◽  
Yongbo Hu ◽  
Xu He ◽  
Yihao Xu ◽  
Xuesong Liu ◽  
...  

We investigated a one-step method for calcium superhydrophobic surface preparation and researched the formation process of loose, flower-like microstructures. Also, we found that the pressing force strongly impacts the dynamics of water droplets.


2021 ◽  
Vol 0 (4) ◽  
pp. 20-24
Author(s):  
N.R. Abıshova ◽  
◽  
G.S. Aliyev ◽  
U.M. Gurbanova ◽  
Y.A. Nuriyev ◽  
...  

The essay is about studies of the electrochemical reduction of nickel ions from a glycine electrolyte by the method of recording cyclic and linear potentiodynamic polarization curves. The effect of the concentration of the main components, potential sweep and temperature on the electrodeposition process of nickel has been studied. It has been found that at the beginning of the process the electrodeposition of the nickel ions from glycine electrolyte is controlled by electrochemical polarization, which turns into concentration polarization


Biosensors ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 249
Author(s):  
Julia Madden ◽  
Colm Barrett ◽  
Fathima R. Laffir ◽  
Michael Thompson ◽  
Paul Galvin ◽  
...  

We report the microfabrication and characterization of gold microband electrodes on silicon using standard microfabrication methods, i.e., lithography and etching techniques. A two-step electrodeposition process was carried out using the on-chip platinum reference and gold counter electrodes, thus incorporating glucose oxidase onto a platinum-modified, gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The as-fabricated electrodes were studied using optical microscopy, scanning electron microscopy, and atomic force microscopy. The two-step electrodeposition process was conducted in low sample volumes (50 µL) of both solutions required for biosensor construction. Cyclic voltammetry and electrochemical impedance spectroscopy were utilised for electrochemical characterization at each stage of the deposition process. The enzymatic-based microband biosensor demonstrated a linear response to glucose from 2.5–15 mM, using both linear sweep voltammetry and chronoamperometric measurements in buffer-based solutions. The biosensor performance was examined in 30 µL volumes of fetal bovine serum. Whilst a reduction in the sensor sensitivity was evident within 100% serum samples (compared to buffer media), the sensor demonstrated linear glucose detection with increasing glucose concentrations (5–17 mM).