ultrahigh fields
Recently Published Documents


TOTAL DOCUMENTS

38
(FIVE YEARS 9)

H-INDEX

12
(FIVE YEARS 1)

Author(s):  
Enrico Luchinat ◽  
Letizia Barbieri ◽  
Matteo Cremonini ◽  
Lucia Banci

AbstractIn-cell NMR spectroscopy provides precious structural and functional information on biological macromolecules in their native cellular environment at atomic resolution. However, the intrinsic low sensitivity of NMR imposes a big limitation in the applicability of the methodology. In this respect, the recently developed commercial 1.2 GHz NMR spectrometer is expected to introduce significant benefits. However, cell samples may suffer from detrimental effects at ultrahigh fields, that must be carefully evaluated. Here we show the first in-cell NMR spectra recorded at 1.2 GHz on human cells, and we compare resolution and sensitivity against those obtained at 900 and 950 MHz. To evaluate the effects of different spin relaxation rates, SOFAST-HMQC and BEST-TROSY spectra were recorded on intracellular α-synuclein and carbonic anhydrase. Major improvements are observed at 1.2 GHz when analyzing unfolded proteins, such as α-synuclein, while the TROSY scheme improves the resolution for both globular and unfolded proteins.


2021 ◽  
Vol 29 (1) ◽  
pp. e1-e19
Author(s):  
Kamil Uğurbil ◽  
Pierre-Francois Van de Moortele ◽  
Andrea Grant ◽  
Edward J. Auerbach ◽  
Arcan Ertürk ◽  
...  
Keyword(s):  

2020 ◽  
Vol 14 ◽  
Author(s):  
Maxime Yon ◽  
Qingjia Bao ◽  
Odélia Jacqueline Chitrit ◽  
Rafael Neto Henriques ◽  
Noam Shemesh ◽  
...  

Diffusion tensor imaging (DTI) is a well-established technique for mapping brain microstructure and white matter tracts in vivo. High resolution DTI, however, is usually associated with low intrinsic sensitivity and therefore long acquisition times. By increasing sensitivity, high magnetic fields can alleviate these demands, yet high fields are also typically associated with significant susceptibility-induced image distortions. This study explores the potential arising from employing new pulse sequences and emerging hardware at ultrahigh fields, to overcome these limitations. To this end, a 15.2 T MRI instrument equipped with a cryocooled surface transceiver coil was employed, and DTI experiments were compared between SPatiotemporal ENcoding (SPEN), a technique that tolerates well susceptibility-induced image distortions, and double-sampled Spin-Echo Echo-Planar Imaging (SE-EPI) methods. Following optimization, SE-EPI afforded whole brain DTI maps at 135 μm isotropic resolution that possessed higher signal-to-noise ratios (SNRs) than SPEN counterparts. SPEN, however, was a better alternative to SE-EPI when focusing on challenging regions of the mouse brain –including the olfactory bulb and the cerebellum. In these instances, the higher robustness of fully refocused SPEN acquisitions coupled to its built-in zooming abilities, provided in vivo DTI maps with 75 μm nominal isotropic spatial resolution. These DTI maps, and in particular the mean diffusion direction (MDD) details, exhibited variations that matched very well the anatomical features known from histological brain Atlases. Using these capabilities, the development of the olfactory bulb (OB) in live mice was followed from week 1 post-partum, until adulthood. The diffusivity of this organ showed a systematic decrease in its overall isotropic value and increase in its fractional anisotropy with age; this maturation was observed for all regions used in the OB's segmentation but was most evident for the lobules' centers, in particular for the granular cell layer. The complexity of the OB neuronal connections also increased during maturation, as evidenced by the growth in directionalities arising in the mean diffusivity direction maps.


2020 ◽  
Vol 85 (4) ◽  
pp. 2055-2068
Author(s):  
Marlon Pérez‐Rodas ◽  
Rolf Pohmann ◽  
Klaus Scheffler ◽  
Rahel Heule

2020 ◽  
Vol 11 (1) ◽  
Author(s):  
Mihajlo Novakovic ◽  
Ēriks Kupče ◽  
Andreas Oxenfarth ◽  
Marcos D. Battistel ◽  
Darón I. Freedberg ◽  
...  

Abstract Multidimensional TOCSY and NOESY are central experiments in chemical and biophysical NMR. Limited efficiencies are an intrinsic downside of these methods, particularly when targeting labile sites. This study demonstrates that the decoherence imparted on these protons through solvent exchanges can, when suitably manipulated, lead to dramatic sensitivity gains per unit time in the acquisition of these experiments. To achieve this, a priori selected frequencies are encoded according to Hadamard recipes, while concurrently subject to looped selective inversion or selective saturation procedures. Suitable processing then leads to protein, oligosaccharide and nucleic acid cross-peak enhancements of ≈200–1000% per scan, in measurements that are ≈10-fold faster than conventional counterparts. The extent of these gains will depend on the solvent exchange and relaxation rates of the targeted sites; these gains also benefit considerably from the spectral resolution provided by ultrahigh fields, as corroborated by NMR experiments at 600 MHz and 1 GHz. The mechanisms underlying these experiments’ enhanced efficiencies are analyzed on the basis of three-way polarization transfer interplays between the water, labile and non-labile protons, and the experimental results are rationalized using both analytical and numerical derivations. Limitations as well as further extensions of the proposed methods, are also discussed.


2020 ◽  
Vol 6 (3) ◽  
pp. 24-27
Author(s):  
Maíra M. Garcia ◽  
Khallil T. Chaim ◽  
Maria C. G. Otaduy ◽  
Andreas Rennings ◽  
Daniel Erni ◽  
...  

AbstractDipole radiofrequency (RF) elements have been successfully used to compose multi-channel RF coils for ultrahigh fields (UHF) magnetic resonance imaging (MRI). As magnetic components of RF fields (B1) can be very inhomogeneous at UHF (B0≥7T), dielectric pads with high dielectric constants were proposed to improve the B1 efficiency and homogeneity [1]. Dielectric pads can be used as a passive B1 shimmimg technique thanks to inducing a strong secondary magnetic field in their vicinity. The use of such dielectric pads affect not only the B1 field but also the electric field. This in turn affects the specific absorption rate (SAR) and consequently the temperature distribution inside the patient’s body. To study these effects, a 29 cm-long transmission dipole RF coil element terminated by two meander was used for 7T MRI [2]. Using a cylindrical agarose-gel phantom, numerical and experimental results were analyzed with respect to homogeneity and amplitude of the magnetic and electric fields generated by the RF element in various configurations with and without dielectric pads. Calculated and measured B1 results were cross-checked and found to be in good agreement. When using dielectric pads B1 homogeneity and magnitude increase in regions where it was previously weak or insufficient. Calculations suggest that SAR distribution will change when using the pads.


2019 ◽  
Vol 6 (2) ◽  
Author(s):  
M. Murakami ◽  
A. Arefiev ◽  
M. A. Zosa ◽  
J. Honrubia
Keyword(s):  

2019 ◽  
Vol 28 (3) ◽  
pp. 173-188 ◽  
Author(s):  
Sebastian C. Niesporek ◽  
Armin M. Nagel ◽  
Tanja Platt
Keyword(s):  

Author(s):  
Thoralf Niendorf ◽  
Till Huelnhagen ◽  
Lukas Winter ◽  
Katharina Paul

Sign in / Sign up

Export Citation Format

Share Document