pulsed electrical field
Recently Published Documents


TOTAL DOCUMENTS

21
(FIVE YEARS 5)

H-INDEX

7
(FIVE YEARS 0)

Author(s):  
Atul Verma ◽  
Samuel J. Asivatham ◽  
Thomas Deneke ◽  
Quim Castellvi ◽  
Robert E Neal

Pulsed electrical field (PEF) energy is a promising technique for catheter ablation of cardiac arrhythmias. In this article, the key aspects that need to be considered for safe and effective PEF delivery are reviewed, and their impact on clinical feasibility is discussed. The most important benefit of PEF appears to be the ability to kill cells through mechanisms that do not alter stromal proteins, sparing sensitive structures to improve safety, without sacrificing cardiomyocyte ablation efficacy. Many parameters affect PEF treatment outcomes, including pulse intensity, waveform shape, and number of pulses, as well as electrode configuration and geometry. These physical and electrical characteristics must be titrated carefully to balance target tissue effects with collateral implications (muscle contraction, temperature rise, risk of electrical arcing events). It is important to note that any combination of parameters affecting PEF needs to be tested for clinical efficacy and safety. Applying PEF clinically requires knowledge of the fundamentals of this technology to exploit its opportunities and generate viable, durable health improvements for patients.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3492
Author(s):  
Yahia Achour ◽  
Jacek Starzyński ◽  
Jacek Rąbkowski

The paper introduces a new design of Marx generator based on modular stages using Silicon Carbide MOSFETs (SiC-MOSFET) aimed to be used in biomedical applications. In this process, living cells are treated with intense nanosecond Pulsed Electrical Field (nsPEF). The electric field dose should be controlled by adjusting the pulse parameters such as amplitude, repetition rate and pulse-width. For this purpose, the structure of the proposed generator enables negative pulses with a quasi-rectangular shape, controllable amplitude, pulse-width and repetition-rate. A complete simulation study was conducted in ANSYS-Simplorer to verify the overall performance. A compact, modular prototype of Marx generator was designed with 1.7 kV rated SiC-MOSFETs and, finally, a set of experiments confirmed all expected features.


2021 ◽  
Vol 11 (10) ◽  
pp. 4611
Author(s):  
Dana Middendorf ◽  
Ute Bindrich ◽  
Claudia Siemer ◽  
Stefan Töpfl ◽  
Volker Heinz

The increased consumption of reduced-fat or non-fat products leads to a reduced intake of fat-soluble bioactive substances, such as fat-soluble vitamins. Due to their natural role as transport systems for hydrophobic substances, casein micelles (CM) might depict a viable system. The structure of CM is characterized by a lipophilic core stabilized by an electric double layer-like structure. Modification allows accessibility of the core and, therefore, the inclusion of fat-soluble bioactive substances. Well-known modifications are pH reduction and use of rennet enzyme. A completely new procedure to modify CM structure is offered by pulsed electrical fields (PEF). The principle behind PEF is called electroporation and affects the electric double layer of CM so that it is interrupted. In this way, lipophilic substances can be incorporated into CM. In this work, we evaluated integration of β-carotene into native CM by an industry-compatible process to overcome disadvantages associated with the use of Na-caseinate and avoid great technical effort, e.g., due to treatment with high hydrostatic pressure. Our research has shown that PEF can be used for disintegration of CM and that significant amounts of β-carotene can be incorporated in CM. Furthermore, after disintegration using PEF, a combination of another PEF and thermal treatment was applied to restructure CM and trap significant amounts of β-carotene, permanently, ending up with an encapsulation efficiency of 78%.


2017 ◽  
Vol 32 (3) ◽  
pp. 641-648 ◽  
Author(s):  
Gabriella de Paula Marcondes Ferrei Leite ◽  
Lais Mara Siqueira das Neves ◽  
Carlos Alberto Silva ◽  
Rinaldo Roberto de Jesus Guirro ◽  
Thamires Rodrigues de Souza ◽  
...  

2016 ◽  
Vol 2 (3) ◽  
pp. e1501478 ◽  
Author(s):  
Qiang Zheng ◽  
Yang Zou ◽  
Yalan Zhang ◽  
Zhuo Liu ◽  
Bojing Shi ◽  
...  

Transient electronics built with degradable organic and inorganic materials is an emerging area and has shown great potential for in vivo sensors and therapeutic devices. However, most of these devices require external power sources to function, which may limit their applications for in vivo cases. We report a biodegradable triboelectric nanogenerator (BD-TENG) for in vivo biomechanical energy harvesting, which can be degraded and resorbed in an animal body after completing its work cycle without any adverse long-term effects. Tunable electrical output capabilities and degradation features were achieved by fabricated BD-TENG using different materials. When applying BD-TENG to power two complementary micrograting electrodes, a DC-pulsed electrical field was generated, and the nerve cell growth was successfully orientated, showing its feasibility for neuron-repairing process. Our work demonstrates the potential of BD-TENG as a power source for transient medical devices.