optoelectronic sensor
Recently Published Documents


TOTAL DOCUMENTS

112
(FIVE YEARS 24)

H-INDEX

12
(FIVE YEARS 1)

2021 ◽  
Vol 56 ◽  
pp. 50-60
Author(s):  
V.S. Kretulis ◽  

A model sample of a monomodular hardware-software optoelectronic sensor of k-factor, meteorological range of visibility and atmosphere transparency with high technical and operational characteristics of small -sized execution is developed and created. The combination in the algorithm of functioning of the developed hardware-software methods of sensor creation provided increase of accuracy and invariance of results of measurement concerning external background illumination and self-testing with automatic correction of pollution effect of optical windows of the sensor. Continuous monitoring of the degree of contamination of optical windows provides an opportunity in case of detection of exceeding the permissible level of pollution to provide the operator with information about the need for preventive work. The proposed method of automatic correction of contamination of optical windows either completely eliminates or significantly increases the time interval of their mechanical cleaning operations, which reduces labour costs for maintenance of the sensor. The analysis of technical capabilities of the nodes of the model sample of the sensor allowed to estimate its basic meteorological parameters: the k-factor – (0.17÷1.11∙10-4) m-1, the meteorological visibility – (18÷27∙103 ) m and the atmosphere transparency per 1 km of the layer – (0÷0.895). The developed meteorological sensor can be used as a basic remote-controlled instrument for measuring meteorological parameters of the state of the atmosphere at the hydrometeorological stations of the country, mobile meteorological stations, stationary meteorological stations of road and air services to ensure guaranteed safety of workers.


Sensors ◽  
2021 ◽  
Vol 21 (23) ◽  
pp. 7993
Author(s):  
Meijun Zhang ◽  
Qipeng Lu ◽  
Haonan Tian ◽  
Dejiang Wang ◽  
Cheng Chen ◽  
...  

In order to improve the image quality of the aerial optoelectronic sensor over a wide range of temperature changes, high thermal adaptability of the primary mirror as the critical components is considered. Integrated optomechanical analysis and optimization for mounting primary mirrors are carried out. The mirror surface shape error caused by uniform temperature decrease was treated as the objective function, and the fundamental frequency of the mirror assembly and the surface shape error caused by gravity parallel or vertical to the optical axis are taken as the constraints. A detailed size optimization is conducted to optimize its dimension parameters. Sensitivities of the optical system performance with respect to the size parameters are further evaluated. The configuration of the primary mirror and the flexure are obtained. The simulated optimization results show that the size parameters differently affect the optical performance and which factors are the key. The mirror surface shape error under 30 °C uniform temperature decrease effectively decreased from 26.5 nm to 11.6 nm, despite the weight of the primary mirror assembly increases by 0.3 kg. Compared to the initial design, the value of the system’s modulation transfer function (0° field angle) is improved from 0.15 to 0.21. Namely, the optical performance of the camera under thermal load has been enhanced and thermal adaptability of the primary mirror has been obviously reinforced after optimization. Based on the optimized results, a prototype of the primary mirror assembly is manufactured and assembled. A ground thermal test was conducted to verify difference in imaging quality at room and low temperature, respectively. The image quality of the camera meets the requirements of the index despite degrading.


Electronics ◽  
2021 ◽  
Vol 10 (18) ◽  
pp. 2301
Author(s):  
Laurent Patier ◽  
Sébastien Lalléchère

This work is dedicated to the assessment of the filtering performances of an optoelectronic sensor for space applications. Particular care is taken concerning the power supply subsystem (here voltage shifter integrated circuit), which is part of the electromagnetic compatibility (EMC) compliance of an imaging equipment embedded on spacecrafts. The proposed methodology aims at two major targets: First, evaluating the Filter Effectiveness (FE) subject concerning varying parameters (including filter topology, parasitic effects and source/load impedance variations); second, quantifying the relative importance of representative equivalent electrical components through sensitivity analyses (nominal and parasitic values). The latter point is of utmost importance considering the expected versatility of such systems, such as manufacturing tolerances, for instance. Nominal values and/or components are often badly defined for confidentiality reasons, lack of knowledge or pure ignorance of inputs. An analytical deterministic formulation (here through the transfer matrix approach) is proposed and completed with an original stochastic strategy (Reduced Order Clustering, ROC). This ensures the reliable assessment of both statistical filter performances and most influential parameters, jointly with computational resources saving relatively to brute force Monte Carlo simulations.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Qian-Bing Zhu ◽  
Bo Li ◽  
Dan-Dan Yang ◽  
Chi Liu ◽  
Shun Feng ◽  
...  

AbstractThe challenges of developing neuromorphic vision systems inspired by the human eye come not only from how to recreate the flexibility, sophistication, and adaptability of animal systems, but also how to do so with computational efficiency and elegance. Similar to biological systems, these neuromorphic circuits integrate functions of image sensing, memory and processing into the device, and process continuous analog brightness signal in real-time. High-integration, flexibility and ultra-sensitivity are essential for practical artificial vision systems that attempt to emulate biological processing. Here, we present a flexible optoelectronic sensor array of 1024 pixels using a combination of carbon nanotubes and perovskite quantum dots as active materials for an efficient neuromorphic vision system. The device has an extraordinary sensitivity to light with a responsivity of 5.1 × 107 A/W and a specific detectivity of 2 × 1016 Jones, and demonstrates neuromorphic reinforcement learning by training the sensor array with a weak light pulse of 1 μW/cm2.


2021 ◽  
Author(s):  
Robert Grosz ◽  
Jakub Nowak ◽  
Dennis Niedermeier ◽  
Jędrzej Mijas ◽  
Wiebke Frey ◽  
...  

<p>A narrow-band optical hygrometer FIRH (Fast Infrared Hygrometer, Nowak et al., 2016), based on absorption of laser light at wavelength λ=1364.6896 nm was used for contactless measurements of humidity inside the measurement volume of LACIS-T (turbulent Leipzig Aerosol Cloud Interaction Simulator, Niedermeier et al., 2020). LACIS-T is a multi-purpose moist-air wind tunnel for investigating atmospherically relevant interactions between turbulence and cloud microphysical processes under well-defined and reproducible laboratory conditions. Main goals of the experiment were:</p><p>1) characterization and evaluation of the FIRH hygrometer in controlled conditions,</p><p>2) characterization of fast turbulent humidity fluctuations inside LACIS-T.</p><p> </p><p>Collected results indicate, that FIRH can be used to characterize turbulent fluctuations of humidity in scales of tens of centimeters with the temporal resolution of 2 kHz and presumably more. Interestingly, scanning of LACIS-T measurement volume indicated existence of turbulence and wave-like features for the investigated measurement setup in its  central part, where air streams of different thermodynamical properties, yet the same mean velocity mix intensively. , However, the setup for cloud measurements include an additional flow (i.e., an aerosol flow) in the central part strongly reducing the wave-like features. In other words, cloud process studies are most likely unaffected by these features.</p><p>Finally, the experiments proved that contactless measurements of humidity conducted from outside the measurement volume of LACIS-T are useful, on condition of corrections of glass window transmission and interferences.</p><p> </p><p>Niedermeier, D., Voigtländer, J., Schmalfuß, S., Busch, D., Schumacher, J., Shaw, R. A., and Stratmann, F. (2020): Characterization and first results from LACIS-T: a moist-air wind tunnel to study aerosol–cloud–turbulence interactions, Atmos. Meas. Tech., 13, 2015-2033, doi:10.5194/amt-13-2015-2020.</p><p>Nowak J., Magryta P., Stacewicz T., Kumala W., Malinowski S.P., 2016: Fast optoelectronic sensor of water concentration, Optica Applicata, vol. 46(4) , pp. 607-618 , doi: 10.5277/oa160408</p>


2021 ◽  
Author(s):  
Alexandre Allil ◽  
Fábio Dutra ◽  
Cesar Cosenza Carvalho ◽  
Alex Dante ◽  
Regina Allil ◽  
...  

2020 ◽  
Vol 20 (2020) ◽  
pp. 226-227
Author(s):  
Alexandre Silva Allil ◽  
Fábio da S. Dutra ◽  
Marcelo Martins Werneck ◽  
Regina Célia da Silva Barros Allil ◽  
Cesar Cosenza De Carvalho

Sign in / Sign up

Export Citation Format

Share Document