magnetic microscopy
Recently Published Documents


TOTAL DOCUMENTS

109
(FIVE YEARS 13)

H-INDEX

15
(FIVE YEARS 0)

Author(s):  
Z. Pastore ◽  
P. Lelievre ◽  
S. A. McEnroe ◽  
N. S. Church


Author(s):  
Razmik A. Hovhannisyan ◽  
Sergey Yu. Grebenchuk ◽  
Denis S. Baranov ◽  
Dimitri Roditchev ◽  
Vasily S. Stolyarov


2021 ◽  
Vol 92 (12) ◽  
pp. 123701
Author(s):  
K. Barr ◽  
T. Cookson ◽  
K. G. Lagoudakis


Nanomaterials ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 2197
Author(s):  
Frederico V. Gutierrez ◽  
Anna De Falco ◽  
Elder Yokoyama ◽  
Leonardo A. F. Mendoza ◽  
Cleanio Luz-Lima ◽  
...  

This study aimed to systematically understand the magnetic properties of magnetite (Fe3O4) nanoparticles functionalized with different Pluronic F-127 surfactant concentrations (Fe3O4@Pluronic F-127) obtained by using an improved magnetic characterization method based on three-dimensional magnetic maps generated by scanning magnetic microscopy. Additionally, these Fe3O4 and Fe3O4@Pluronic F-127 nanoparticles, as promising systems for biomedical applications, were prepared by a wet chemical reaction. The magnetization curve was obtained through these three-dimensional maps, confirming that both Fe3O4 and Fe3O4@Pluronic F-127 nanoparticles have a superparamagnetic behavior. The as-prepared samples, stored at approximately 20 °C, showed no change in the magnetization curve even months after their generation, resulting in no nanoparticles free from oxidation, as Raman measurements have confirmed. Furthermore, by applying this magnetic technique, it was possible to estimate that the nanoparticles’ magnetic core diameter was about 5 nm. Our results were confirmed by comparison with other techniques, namely as transmission electron microscopy imaging and diffraction together with Raman spectroscopy. Finally, these results, in addition to validating scanning magnetic microscopy, also highlight its potential for a detailed magnetic characterization of nanoparticles.



2021 ◽  
Vol 31 (5) ◽  
pp. 1-4
Author(s):  
Zeyu Wu ◽  
Kohei Higashikawa ◽  
Kazutaka Imamura ◽  
Zhongtang Xu ◽  
Yanwei Ma ◽  
...  


2021 ◽  
Vol 15 (5) ◽  
Author(s):  
Zeeshawn Kazi ◽  
Isaac M. Shelby ◽  
Hideyuki Watanabe ◽  
Kohei M. Itoh ◽  
Vaithiyalingam Shutthanandan ◽  
...  


2021 ◽  
Vol 15 (4) ◽  
Author(s):  
Connor A. Hart ◽  
Jennifer M. Schloss ◽  
Matthew J. Turner ◽  
Patrick J. Scheidegger ◽  
Erik Bauch ◽  
...  


2021 ◽  
Author(s):  
Peter Lelièvre ◽  
Zeudia Pastore ◽  
Nathan Church ◽  
Madeline Lee ◽  
Hirokuni Oda ◽  
...  

<p>We are using 3D magnetic vector inversion (MVI) of scanning magnetic microscopy (SMM) data to investigate the fine‐scale magnetization of rock samples, and particularly of their remanence carriers, which can record geologically meaningful information. Previous investigations of magnetite grains suggest variable remanence intensities and directions coherent with multidomain behaviour. This research seeks to improve our understanding of the contribution of different microstructures on remanence acquisition.</p><p>SMM offers a spatial resolution down to tens of micrometers, allowing detailed investigation of discrete magnetic mineral grains, or magnetic textures and structures. However, all magnetic measurements are, at some scale, bulk measurements. Further analysis of the data is required to extract information about the magnetization within the samples: for this, we employ state-of-the-art MVI methods. The MVI problem suffers from a high degree of nonuniqueness. Additional constraints are required to obtain accurate, reliable and interpretable results. Such constraints are readily available for this application.</p><p>SMM instruments use magnetic shields or Helmholtz coils to allow collection of data in controlled magnetic fields, enabling the removal of induced magnetization effects. Measurements can be taken both above and below the sample. Individual magnetized mineral grains are easily outlined through optical and electron microscopy. The internal geometry of the oxide mineral phases and compositions can also be constrained. Physical property information constrains the range of magnetization intensity. As such, there is a tremendous amount of constraining information invaluable for reducing the nonuniqueness of the inverse problem. We use a highly flexible and functional inversion software package, MAGNUM, developed jointly at Mount Allison University and Memorial University of Newfoundland, that allows incorporation of all available constraints.</p><p>We take a multitiered approach for investigating specific magnetized grains. First, coarse regional inversions are performed to assess and remove any effects of other magnetized grains in the vicinity. The entire grain is then modelled with a homogeneous magnetization to obtain an approximate but representative bulk magnetization. The grain is then modelled as a collection of independent subdomains, each with a different homogeneous magnetization direction. Subsequently, more heterogeneous scenarios are considered by relaxing inversion constraints until the data can be fit to the desired degree.</p><p>Obtaining reliable information about the magnetic mineralogy of rock samples is vital for an understanding of the origin of rock bulk behaviour in both the laboratory and larger scale magnetic surveys. This work is among the first to simultaneously invert SMM data collected above and below a thin sample, which is critical for improving depth resolution on thicker samples. It is also the first time we have been able to incorporate all available constraints into inverse modelling to improve results.</p>





Sign in / Sign up

Export Citation Format

Share Document