aseptic prosthesis loosening
Recently Published Documents


TOTAL DOCUMENTS

14
(FIVE YEARS 5)

H-INDEX

5
(FIVE YEARS 1)

2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Bo Bao ◽  
Crystal S. Liu ◽  
Edward C. O. Masson ◽  
Jonathan T. Abele

Abstract Purpose To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty. Methods A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard. Results The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%). Conclusion SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.


2021 ◽  
Author(s):  
Bo Bao ◽  
Crystal Sixian Liu ◽  
Edward C.O Masson ◽  
Jonathan Abele

Abstract Purpose To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty. Methods A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013 and July 1, 2018 was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/ radiologic follow-up at a minimum of one year were used as the reference standard. Results The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%) respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%). Conclusion SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.


2021 ◽  
Author(s):  
Zhantao Deng ◽  
Ruiying Zhang ◽  
Mengyuan Li ◽  
Shuai Wang ◽  
Guangtao Fu ◽  
...  

Our study demonstrated wear particles, which are generated by the abrasion of implanted prostheses, could induced STAT3 activation in osteoblasts. And further, inflammatory responses and RANKL expression would activate osteoclasts and cause osteolysis.


2020 ◽  
Author(s):  
Bo Bao ◽  
Crystal Liu ◽  
Edward C.O Masson ◽  
Jonathan Abele

Abstract Purpose To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty. Methods A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013 and July 1, 2018 was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/ radiologic follow-up at a minimum of one year were used as the reference standard. Results The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%) respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%). Conclusion SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.


Materials ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 3495 ◽  
Author(s):  
Sophie Burtscher ◽  
Peter Krieg ◽  
Andreas Killinger ◽  
Ali Al-Ahmad ◽  
Michael Seidenstücker ◽  
...  

One of the most common causes of implant failure is aseptic prosthesis loosening. Another frequent complication after prosthesis implant is the microbial colonization of the prosthesis surface, which often leads to a replacement of the prosthesis. One approach to reduce these complications is the application of bioactive substances to implant surfaces. Both an antibiotic prophylaxis and a faster osteointegration can be obtained by incorporation of bactericidal active metals in degradable calcium phosphate (CaP) coatings. In this study, thin degradable calcium phosphate ceramic coatings doped with silver (Ag), copper (Cu), and bismuth (Bi) on a titanium substrate were prepared with the aid of the high-velocity suspension flame spraying (HVSFS) coating process. To characterize the samples surface roughness, brightfield microscopy of the coatings, X-ray diffraction (XRD)-analysis for definition of the phase composition of the layers, Raman spectroscopy for determination of the phase composition of the contained metals, element-mapping for Cu-content verification, release kinetics for detection of metal ions and ceramic components of the coatings were carried out. The aim of this study was to evaluate in vitro biocompatibility and antimicrobial activity of the coatings. For biocompatibility testing, growth experiments were performed using the cell culture line MG-63. Cell viability was investigated by Giemsa staining and live/dead assay. The WST-1 kit was used to quantify cell proliferation and vitality in vitro and the lactate dehydrogenase (LDH) kit to quantify cytotoxicity. The formation of hydroxyapatite crystals in simulated body fluid was investigated to predict bioactivity in vivo. The Safe Airborne Antibacterial Assay with Staphylococcus aureus (S. aureus) was used for antimicrobial testing. The results showed good biocompatibility of all the metal doped CaP coatings, furthermore Cu and Ag doped layers showed significant antibacterial effects against S. aureus.


2017 ◽  
Vol 49 ◽  
pp. 541-554 ◽  
Author(s):  
Zhantao Deng ◽  
Zhenheng Wang ◽  
Jiewen Jin ◽  
Yong Wang ◽  
Nirong Bao ◽  
...  

2017 ◽  
Vol 8 (4) ◽  
pp. 342 ◽  
Author(s):  
Max J Friedrich ◽  
Matthias D Wimmer ◽  
Jan Schmolders ◽  
Andreas C Strauss ◽  
Milena M Ploger ◽  
...  

2016 ◽  
Vol 10 (1) ◽  
pp. 241-251 ◽  
Author(s):  
Erhan Sukur ◽  
Yunus Emre Akman ◽  
Yusuf Ozturkmen ◽  
Fatih Kucukdurmaz

Background:Inflammatory responses to wear debris cause osteolysis that leads to aseptic prosthesis loosening and hip arthroplasty failure. Although osteolysis is usually associated with aseptic loosening, it is rarely seen around stable implants. Aseptic implant loosening is a simple radiologic phenomenon, but a complex immunological process. Particulate debris produced by implants most commonly causes osteolysis, and this is called particle-associated periprosthetic osteolysis (PPO).Objective:The objective of this review is to outline the features of particle-associated periprosthetic osteolysis to allow the physician to recognise this condition and commence early treatment, thereby optimizing patient outcome.Methods:A thorough literature search was performed using available databases, including Pubmed, to cover important research published covering particle-associated PPO.Results:Although osteolysis causes bone resorption, clinical, animal, andin vitrostudies of particle bioreactivity suggest that particle-associated PPO represents the culmination of several biological reactions of many cell types, rather than being caused solely by the osteoclasts. The biological activity is highly dependent on the characteristics and quantity of the wear particles.Conclusion:Despite advances in total hip arthroplasty (THA), particle-associated PPO and aseptic loosening continue to be major factors that affect prosthetic joint longevity. Biomarkers could be exploited as easy and objective diagnostic and prognostic targets that would enable testing for osteolysis after THA. Further research is needed to identify new biomarkers in PPO. A comprehensive understanding of the underlying biological mechanisms is crucial for developing new therapeutic interventions to reverse or suppress biological responses to wear particles.


2008 ◽  
Vol 33 (3) ◽  
pp. 873-877 ◽  
Author(s):  
Jon A. Tsai ◽  
Martin K. Andersson ◽  
Mikael Ivarsson ◽  
Barbro Granberg ◽  
André Stark