Visual acuity, defocus curve and patient satisfaction of a new hybrid EDOF-multifocal diffractive intraocular lens

2021 ◽  
pp. 112067212110573
Author(s):  
Cem Ozturkmen ◽  
Cem Kesim ◽  
Pinar Gunel Karadeniz ◽  
Afsun Sahin

Purpose: To evaluate the visual acuity, defocus curve and visual quality of life following bilateral implantation of a new hybrid extended depth of focus (EDOF)-multifocal diffractive intraocular lens (IOL). Methods: Patients who underwent cataract surgery with bilateral implantation of Tecnis Synergy IOL were enrolled in this study. The main outcomes were defined as uncorrected distant, intermediate and near visual acuities (UDVA, UIVA and UNVA, respectively), defocus curve and VF-14 questionnaire aimed for visual performance. Results: The mean ± SD values for binocular UDVA, UIVA and UNVA were −0.01 ± 0.04, 0.05 ± 0.03 and 0.03 ± 0.05 logMAR, respectively. Defocus curve showed a continuous vision above 0.16 logMAR between +0.50 D and −2.50 D. Patients had good visual performance with mean VF-14 scores above 3 points. Driving at night (3.47 ± 0.64) was found to be the most difficult task to perform. Spectacle independence was 100% for both distant and near vision. Conclusion: Bilateral implantation of Tecnis Synergy IOL in cataract patients shows good visual acuity and performance, covering a good visual range without any need of spectacles.

2021 ◽  
pp. 112067212110676
Author(s):  
Cem Ozturkmen ◽  
Cem Kesim ◽  
Pinar Gunel Karadeniz ◽  
Afsun Sahin

Purpose To compare visual acuity, defocus curve and visual quality of life performances of a new hybrid refractive-diffractive intraocular lens (IOL) and a trifocal diffractive IOL. Methods Patients who underwent cataract surgery with bilateral implantation of ZFR00V or TFNT00 IOLs were enrolled in this study. The main outcomes were defined as uncorrected distant, intermediate and near visual acuities (UDVA, UIVA and UNVA, respectively), defocus curve and VF-14 questionnaire aimed for visual performance. Results Fifty patients, of whom 30 had bilateral ZFR00V implantation, were enrolled in the study. Patients with ZFR00V had significantly better UIVA than patients with TFNT00 (0.05 ± 0.03 vs. 0.07 ± 0.04 logMAR, P = 0.02). Defocus curve showed significantly higher visual acuity in intermediate range for ZFR00V IOL between −1.00 and −1.50 dioptres (all P < 0.05). All patients had good visual performance with mean VF-14 scores above 3 points with no significant difference between two IOL models. Spectacle independence was 100% for both distant and near vision in both group of patients. Conclusion Bilateral implantation of ZFR00V in cataract patients shows better intermediate visual acuity scores and similar daily visual performance when compared with trifocal TFNT00 IOL.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El-Hennawi ◽  
Ehab F. Mossallam

Abstract Background This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification. Results The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was − 0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 ft) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 ft) and mean Uncorrected near visual acuity (UCNVA) was 0.87 ± 0.20 decimal (snellen equivalent 23 ft). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence. Trial registration Registration number and date: NCT04465279 on July 10, 2020.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2021 ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El Hennawi ◽  
Ehab F. Mossallam

Abstract Background: This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification.Results: The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was –0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 feet) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 feet) and mean Uncorrected near visual acuity (UCNVA)was 0.87 ± 0.20 decimal (snellen equivalent 23 feet). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion: Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


Author(s):  
Victor Duque ◽  
Carolina de la Pinta ◽  
Ciriaco Corral ◽  
Carmen Vallejo ◽  
Margarita Martin ◽  
...  

Abstract Introduction: Choroidal metastases are the most frequent intraocular secondary tumours, with a prevalence of 2–7% according to the literature. Our aim was to review a clinical case of choroidal metastasis. We present a case of a 63-year-old male patient diagnosed in 2018 with lung adenocarcinoma cT4N0M1. The patient had three metastases in the brain, which were successfully treated with radiosurgery (RS). The patient was treated with chemotherapy with pemetrexed–cisplatin schedule. Five months after diagnosis, the patient presented with decreased vision in the right eye. After ophthalmologic evaluation, he was diagnosed with a right choroidal metastasis, which was treated with external beam radiotherapy with 20 Gy in five fractions, resulting in improved visual acuity and a complete clinical and radiological response. The patient took part in a clinical trial that continued with systemic chemotherapy. Twenty-two months after radiotherapy to the eye, the patient has good visual acuity without any side effects. Conclusions: Choroidal metastasis treated with radiotherapy achieves good local control, with limited side effects, allowing an improvement in visual acuity and consequently, an improvement in the patient´s quality of life.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Chengshu Xie ◽  
Shaurya Jauhari ◽  
Antonio Mora

Abstract Background Gene Set Analysis (GSA) is arguably the method of choice for the functional interpretation of omics results. The following paper explores the popularity and the performance of all the GSA methodologies and software published during the 20 years since its inception. "Popularity" is estimated according to each paper's citation counts, while "performance" is based on a comprehensive evaluation of the validation strategies used by papers in the field, as well as the consolidated results from the existing benchmark studies. Results Regarding popularity, data is collected into an online open database ("GSARefDB") which allows browsing bibliographic and method-descriptive information from 503 GSA paper references; regarding performance, we introduce a repository of jupyter workflows and shiny apps for automated benchmarking of GSA methods (“GSA-BenchmarKING”). After comparing popularity versus performance, results show discrepancies between the most popular and the best performing GSA methods. Conclusions The above-mentioned results call our attention towards the nature of the tool selection procedures followed by researchers and raise doubts regarding the quality of the functional interpretation of biological datasets in current biomedical studies. Suggestions for the future of the functional interpretation field are made, including strategies for education and discussion of GSA tools, better validation and benchmarking practices, reproducibility, and functional re-analysis of previously reported data.


2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
John S. M. Chang ◽  
Jack C. M. Ng ◽  
Vincent K. C. Chan ◽  
Antony K. P. Law

Purpose. To report visual performance and quality of life after implantation of a bifocal diffractive multifocal intraocular lens (MIOL) in postmyopic laser in situ keratomileusis (LASIK) patients.Methods. Prospective, observational case series. Patients with prior myopic LASIK who had implantation of Tecnis ZMA00/ZMB00 MIOL (Abbott Medical Optics) at Hong Kong Sanatorium and Hospital were included. Postoperative examinations included monocular and binocular distance, intermediate and near visual acuity (VA), and contrast sensitivity; visual symptoms (0–5); satisfaction (1–5); spectacle independence rate; and quality of life.Results. Twenty-three patients (27 eyes) were included. No intraoperative complications developed. Mean monocular uncorrected VA at distance, intermediate, and near were0.13±0.15(standard deviation),0.22±0.15, and0.16±0.15, respectively. Corresponding mean values for binocular uncorrected VA were0.00±0.10,0.08±0.13, and0.13±0.10, respectively. No eyes lost >1 line of corrected distance VA. Contrast sensitivity at different spatial frequencies between operated and unoperated eyes did not differ significantly (allP>0.05). Mean score for halos, night glare, starbursts, and satisfaction were1.46±1.62,1.85±1.69,0.78±1.31, and3.50±1.02, respectively. Eighteen patients (78%) reported complete spectacle independence. Mean composite score of the quality-of-life questionnaire was90.31±8.50out of 100.Conclusions. Implantation of the MIOL after myopic LASIK was safe and achieved good visual performance.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Sri Ganesh ◽  
Sheetal Brar ◽  
Archana Pawar ◽  
Kirti J. Relekar

Purpose. To evaluate the outcomes following bilateral ERV intraocular lens implantation with micromonovision.Methods. 25 subjects underwent bilateral Tecnis Symfony IOL implantation with micromonovision. The dominant eye was targeted for emmetropia and the nondominant eye for myopia of −0.75 D. Uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near visual acuity (UNVA, DCNVA); reading performance; defocus curve; and contrast sensitivity were studied. Follow-ups were conducted at 1 week and 1 and 6 months postoperatively.Results. At 6 months postoperatively, the mean binocular UDVA, CDVA, UNVA, and DCNVA were −0.036 ± 0.09, −0.108 ± 0.07, 0.152 ± 0.11, and 0.216 ± 0.10 logMAR, respectively. Binocular UIVA and DCIVA were 0.048 ± 0.09 and 0.104 ± 0.08 logMAR, respectively, at 60 cm and −0.044 ± 0.09 and 0.012 ± 0.09 logMAR, respectively, at 80 cm. All patients had ≥0.2 logMAR UDVA and UNVA. Reading acuity and reading speeds showed improvement over time. Between defocus range of −2.50 and +1.00 D, the visual acuity remained ≥0.2 logMAR. Contrast sensitivity scores were within the normal range. 4 patients used reading glasses for very fine print.Conclusion. Bilateral ERV IOL implantation leads to excellent outcomes for far and intermediate vision, satisfactory outcomes for near vision, and good tolerance to micromonovision at the end of the 6 months. This trial is registered withCTRI/2015/10/006246.