transseptal approach
Recently Published Documents


TOTAL DOCUMENTS

156
(FIVE YEARS 32)

H-INDEX

20
(FIVE YEARS 1)

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Miguel Quesado ◽  
Ana Sofia Esteves ◽  
Nuno Vieira da Silva ◽  
Tiago Costa ◽  
Nuno Ferreira ◽  
...  

The posterior cruciate ligament (PCL) avulsion fracture is a rare injury and occurs mainly in young patients. The development of arthroscopic techniques and fixation methods has improved the treatment of this entity. This report describes a modified arthroscopic suture fixation of a small tibial avulsion fracture of the PCL. A 17-year-old male, injured in a motorcycle crash, was admitted to the Emergency Department and diagnosed with left knee PCL tibial avulsion fracture, lateral collateral ligament (LCL) femoral avulsion fracture, and patella fracture. The PCL was fixed arthroscopically using a Knee Scorpion and two SutureTapes (Arthrex, Munich-Germany) through of an interlaced configuration at the base of the fragment using a transseptal approach and fixed distally over a cortical button on the anterior cortex. The LCL was repaired with two cannulated screws by a percutaneous approach. At 1 year of follow-up, the fragment was healed with tibiofemoral congruence, and the knee was stable with complete range of motion. The Tegner Lysholm Knee Scoring Scale (TLKSS) was 92.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
AM Zedda ◽  
M Rillo ◽  
A Sultan ◽  
H Ramanna ◽  
I Deisenhofer ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction The clinical benefit of multielectrode high-density (HD) mapping during catheter ablation has been an area of active research. One advantage of HD mapping is improved sensitivity which can lead to better visualization and substrate delineation during the procedure. In addition to the advantages offered by the multielectrode grid mapping catheter (HD Grid), a novel software enable the display of beat-to-beat, dynamic regional mapping data from the current location of HD Grid in real-time (LiveView). The optimal settings and workflows to incorporate the dynamic data into routine ablation procedures have not been explored. Purpose To examine the common settings and workflow patterns among operators from different geographies when using dynamic mapping. Methods Observational procedural data including procedure time, total RF time, workflow preference, and fluoroscopy time, were prospectively collected from operators across Europe, the U.S., and Asia Pacific countries from May to September 2020. Cases from both catheter ablation of atrial and ventricular arrhythmias were included in the analysis. Results A total of 754 cases were collected (428, 133, and 193 cases from Europe, the U.S., and the Asia Pacific region, respectively). The most commonly reported indication across all three geographies was de novo paroxysmal atrial fibrillation (223/754, 30.0%). A steerable sheath was more frequently used with the mapping catheter in Europe and U.S. compared to Asia Pacific countries. Contrary to cases from the U.S. and Asia Pacific countries where the double transseptal approach was the preferred technique for left atrial procedures (78.8% and 55.3%, respectively), the single transseptal approach was more commonly observed in European cases (233/428, 54.4%). Visualization of real-time mapping data after creation of traditional full-chamber maps were commonly observed in all three geographies. Regardless of geography, the CS catheter was commonly used a reference electrode; and the most common map appearance settings for interior projection, exterior projection, and interpolation was 7, 7, and 7 respectively. Voltage cutoff of 0.1 mV, range from 0.01 to 1.5 mV, was most frequently observed for delineating scar in atrial arrhythmia cases analyzed in this dataset. Conclusions While there is a geographical difference in ablation workflow, common settings and patterns can be observed in all three regions. This data suggests that minimal workflow changes are required to incorporate the use of dynamic data into routine procedures. Adaptation of LiveView can help improve procedure efficiency and efficacy by reducing the need for full chamber maps, identifying areas that were under ablated, and confirming ablation endpoints. Further control study examining procedure efficiency and efficacy associated with dynamic mapping may be warranted.


2021 ◽  
Vol 14 (4) ◽  
Author(s):  
Yasuyuki Egami ◽  
Kohei Ukita ◽  
Akito Kawamura ◽  
Hitoshi Nakamura ◽  
Yutaka Matsuhiro ◽  
...  

Author(s):  
Jannik Frings ◽  
Sebastian Weiß ◽  
Jan Kolb ◽  
Peter Behrendt ◽  
Karl-Heinz Frosch ◽  
...  

Abstract Introduction Although open-surgical techniques for the reconstruction of the posterolateral corner (PLC) are well established, the use of arthroscopic procedures has recently increased. When compared with open surgical preparation, arthroscopic orientation in the PLC is challenging and anatomic relations may not be familiar. Nevertheless, a profound knowledge of anatomic key structures and possible structures at risk as well as technical variations of arthroscopic approaches are mandatory to allow a precise and safe surgical intervention. Materials and methods In a cadaveric video demonstration, an anterolateral (AL), anteromedial (AM), posteromedial (PM) and posterolateral (PL) portal, as well as a transseptal approach (TSA) were developed. Key structures of the PLC were defined and sequentially exposed during posterolateral arthroscopy. Finally, anatomic relations of all key structures were demonstrated. Results All key structures of the PLC can be visualized during arthroscopy. Thereby, careful portal placement is crucial in order to allow an effective exposure. Two alternatives of the TSA were described, depending on the region of interest. The peroneal nerve can be visualized dorsal to the biceps femoris tendon (BT), lateral to the soleus muscle (SM) and about 3 cm distal to the fibular styloid (FS). The distal attachment of the fibular collateral ligament (FCL) can be exposed on the lateral side of the fibular head (FH). The fibular attachment of the popliteofibular ligament (PFL) is exposed at the tip of the FS. Conclusion Arthroscopy of the posterolateral recessus allows full visualization of all key structures of the posterolateral corner, which provides the basis for anatomic and safe drill channel placement in PLC reconstruction. A sufficient exposure of relevant anatomic landmarks and precise portal preparation reduce the risk of iatrogenic vascular and peroneal nerve injury.


2021 ◽  
Vol 23 (4) ◽  
Author(s):  
W. Ben-Ali ◽  
R. Ibrahim ◽  
J. Rodès-Cabeau ◽  
R. S. von Bardeleben ◽  
D. Mylotte ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Hui Zhang ◽  
Jing-Yan Wang ◽  
Jian-Hua Lv ◽  
Hai-Bo Hu ◽  
Rui-Gang Xie ◽  
...  

Background: Transcatheter closure of paravalvular leak (PVL) has evolved into an alternative to surgery in high-risk patients. In this study, we introduce a new access for transcatheter closure of PVL and seek to evaluate the feasibility and safety of this access.Methods: We retrospectively analyzed patients undergoing transbrachial access for transcatheter mitral or aortic PVL closure (August 2017–November 2019) at our hospital. All patients underwent puncture of the brachial artery under local anesthesia.Results: The study population included 11 patients, with an average age of 55.91 ± 14.82 years. Ten out of 11 patients were successfully implanted with devices via the brachial artery approach, and one patient was converted to the transseptal approach. The technical success rate of transbrachial access was 90.9%. Mean NYHA functional class improved from 3.1 ± 0.5 before the procedure to 1.9 ± 0.5 after PVL closure. Severe paravalvular regurgitation (PVR) in five patients and moderate PVR in six patients prior to the procedure were significantly reduced to mild in four patients and none in seven patients after the procedure. Complications included one case of pseudoaneurysm and one case of moderate hemolysis aggravation after closure. One patient had an unknown cause of sudden death within 24 h after the procedure. The half-year mortality rate during follow-up was 9.1% (1/11).Conclusions: Transbrachial access for transcatheter closure of PVL may be a feasible and safe treatment and should include well-selected patients. It has several potential advantages of simplifying the procedure process and reducing postprocedural bed rest time.


2021 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
John J. Squiers ◽  
J. James Edelman ◽  
Vinod H. Thourani ◽  
Michael J. Mack

Sign in / Sign up

Export Citation Format

Share Document