unenhanced computed tomography
Recently Published Documents


TOTAL DOCUMENTS

85
(FIVE YEARS 31)

H-INDEX

12
(FIVE YEARS 2)

2022 ◽  
Vol 11 (1) ◽  
Author(s):  
Laure Felix ◽  
Peggy Jacon ◽  
Maxime Lugosi ◽  
Justine Cristante ◽  
Julie Roux ◽  
...  

Background and Objective It has been reported recently in a cross sectional study that patients with amiodarone induced thyrotoxicosis (AIT) showed a ‘white’ thyroid on unenhanced computed tomography, due to intrathyroid iodine accumulation. However, the link between increase in thyroid radiologic density and amiodarone induced thyrotoxicosis remains unknown. We sought to analyze this link. Methods We present the case of a 34-year-old patient with severe sarcoidosis-related hypertrophic cardiomyopathy who was followed with successive unenhanced CT scans integrated with FDG PET scans. After the first CT scans the patient, who initially had a normal thyroid function, was exposed to amiodarone during 23 months and developed AIT, very likely by thyroiditis (AIT type 2). There were no thyroid antibodies, no evidence of thyroid sarcoidosis on FDG PET scan, while thyroid sonogram showed a homogenous 22 ml moderate goiter with normal echogenicity and no nodules. Results Analysis of the successive enhanced CT scans revealed that after initiation of amiodarone treatment, thyroid radiologic density steadily increased before detection of AIT, peaked after cessation of amiodarone and initiation of thyrotoxicosis treatment, before returning to normal as thyrotoxicosis receded. Thyroid volume also showed a moderate increase, peaking at the detection of thyrotoxicosis, before returning to normal. Conclusion This case suggests that AIT is preceded by a very high intrathyroid iodine accumulation before the ‘burst’ of thyroiditis occurs and that measurements of thyroid gland radiological density might predict the development and remission of AIT.


2021 ◽  
Vol 6 ◽  
pp. 249
Author(s):  
Ze Ming Goh ◽  
Christopher S. Johns ◽  
Tarik Julius ◽  
Samual Barnes ◽  
Krit Dwivedi ◽  
...  

Background: Computed tomography pulmonary angiography (CTPA) has been proposed to be diagnostic for pulmonary hypertension (PH) in multiple studies. However, the utility of the unenhanced CT measurements diagnosing PH has not been fully assessed.  This study aimed to assess the diagnostic utility and reproducibility of cardiac and great vessel parameters on unenhanced computed tomography (CT) in suspected pulmonary hypertension (PH). Methods: In total, 42 patients with suspected PH who underwent unenhanced CT thorax and right heart catheterization (RHC) were included in the study. Three observers (a consultant radiologist, a specialist registrar in radiology, and a medical student) measured the parameters by using unenhanced CT. Diagnostic accuracy of the parameters was assessed by area under the receiver operating characteristic curve (AUC). Inter-observer variability between the consultant radiologist (primary observer) and the two secondary observers was determined by intra-class correlation analysis (ICC). Results: Overall, 35 patients were diagnosed with PH by RHC while 7 patients were not. Main pulmonary arterial (MPA) diameter was the strongest (AUC 0.79 to 0.87) and the most reproducible great vessel parameter. ICC comparing the MPA diameter measurement of the consultant radiologist to the specialist registrar’s and the medical student’s were 0.96 and 0.92, respectively. Right atrial area was the cardiac measurement with highest accuracy and reproducibility (AUC 0.76 to 0.79; ICC 0.980, 0.950) followed by tricuspid annulus diameter (AUC 0.76 to 0.79; ICC 0.790, 0.800). Conclusions: MPA diameter and right atrial areas showed high reproducibility. Diagnostic accuracies of these were within the range of acceptable to excellent, and might have clinical value. Tricuspid annular diameter was less reliable and less diagnostic and was therefore not a recommended diagnostic measurement.


Author(s):  
Salvatore Gitto ◽  
Renato Cuocolo ◽  
Ilaria Emili ◽  
Laura Tofanelli ◽  
Vito Chianca ◽  
...  

AbstractThis study aims to investigate the influence of interobserver manual segmentation variability on the reproducibility of 2D and 3D unenhanced computed tomography (CT)- and magnetic resonance imaging (MRI)-based texture analysis. Thirty patients with cartilaginous bone tumors (10 enchondromas, 10 atypical cartilaginous tumors, 10 chondrosarcomas) were retrospectively included. Three radiologists independently performed manual contour-focused segmentation on unenhanced CT and T1-weighted and T2-weighted MRI by drawing both a 2D region of interest (ROI) on the slice showing the largest tumor area and a 3D ROI including the whole tumor volume. Additionally, a marginal erosion was applied to both 2D and 3D segmentations to evaluate the influence of segmentation margins. A total of 783 and 1132 features were extracted from original and filtered 2D and 3D images, respectively. Intraclass correlation coefficient ≥ 0.75 defined feature stability. In 2D vs. 3D contour-focused segmentation, the rates of stable features were 74.71% vs. 86.57% (p < 0.001), 77.14% vs. 80.04% (p = 0.142), and 95.66% vs. 94.97% (p = 0.554) for CT and T1-weighted and T2-weighted images, respectively. Margin shrinkage did not improve 2D (p = 0.343) and performed worse than 3D (p < 0.001) contour-focused segmentation in terms of feature stability. In 2D vs. 3D contour-focused segmentation, matching stable features derived from CT and MRI were 65.8% vs. 68.7% (p = 0.191), and those derived from T1-weighted and T2-weighted images were 76.0% vs. 78.2% (p = 0.285). 2D and 3D radiomic features of cartilaginous bone tumors extracted from unenhanced CT and MRI are reproducible, although some degree of interobserver segmentation variability highlights the need for reliability analysis in future studies.


2021 ◽  
Vol 11 ◽  
Author(s):  
Keng He ◽  
Zhao-Tao Zhang ◽  
Zhen-Hua Wang ◽  
Yu Wang ◽  
Yi-Xi Wang ◽  
...  

PurposeTo develop and validate a clinical-radiomic nomogram for the preoperative prediction of the aldosterone-producing adenoma (APA) risk in patients with unilateral adrenal adenoma.Patients and MethodsNinety consecutive primary aldosteronism (PA) patients with unilateral adrenal adenoma who underwent adrenal venous sampling (AVS) were randomly separated into training (n = 62) and validation cohorts (n = 28) (7:3 ratio) by a computer algorithm. Data were collected from October 2017 to June 2020. The prediction model was developed in the training cohort. Radiomic features were extracted from unenhanced computed tomography (CT) images of unilateral adrenal adenoma. The least absolute shrinkage and selection operator (LASSO) regression model was used to reduce data dimensions, select features, and establish a radiomic signature. Multivariable logistic regression analysis was used for the predictive model development, the radiomic signature and clinical risk factors integration, and the model was displayed as a clinical-radiomic nomogram. The nomogram performance was evaluated by its calibration, discrimination, and clinical practicability. Internal validation was performed.ResultsSix potential predictors were selected from 358 texture features by using the LASSO regression model. These features were included in the Radscore. The predictors included in the individualized prediction nomogram were the Radscore, age, sex, serum potassium level, and aldosterone-to-renin ratio (ARR). The model showed good discrimination, with an area under the receiver operating characteristic curve (AUC) of 0.900 [95% confidence interval (CI), 0.807 to 0.993], and good calibration. The nomogram still showed good discrimination [AUC, 0.912 (95% CI, 0.761 to 1.000)] and good calibration in the validation cohort. Decision curve analysis presented that the nomogram was useful in clinical practice.ConclusionsA clinical-radiomic nomogram was constructed by integrating a radiomic signature and clinical factors. The nomogram facilitated accurate prediction of the probability of APA in patients with unilateral adrenal nodules and could be helpful for clinical decision making.


2021 ◽  
Vol 30 (2) ◽  
pp. 192-192
Author(s):  
Lawrence Bonne ◽  
Pieter De Bondt ◽  
Filip Sermon ◽  
Geert Maleux

2021 ◽  
pp. 109776
Author(s):  
Haruto Sugawara ◽  
Takeharu Yoshikawa ◽  
Akira Kunimatsu ◽  
Hiroyuki Akai ◽  
Koichiro Yasaka ◽  
...  

Cancers ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 2021
Author(s):  
Feng Pan ◽  
Thuy D. Do ◽  
Dominik F. Vollherbst ◽  
Philippe L. Pereira ◽  
Götz M. Richter ◽  
...  

Introduction. To explore the feasibility, safety, and efficiency of ethiodized oil tumor marking combined with irreversible electroporation (IRE) for small hepatocellular carcinomas (HCCs) that were invisible on unenhanced computed tomography (CT). Methods. A retrospective analysis of the institutional database was performed from January 2018 to September 2018. Patients undergoing ethiodized oil tumor marking to improve target-HCC visualization in subsequent CT-guided IRE were retrieved. Target-HCC visualization after marking was assessed, and the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNR) were compared between pre-marking and post-marking CT images using the paired t-test. Standard IRE reports, adverse events, therapeutic endpoints, and survival were summarized and assessed. Results. Nine patients with 11 target-HCCs (11.1–18.8 mm) were included. After marking, all target-HCCs demonstrated complete visualization in post-marking CT, which were invisible in pre-marking CT. Quantitatively, the SNR of the target-HCCs significantly increased after marking (11.07 ± 4.23 vs. 3.36 ± 1.79, p = 0.006), as did the CNR (4.32 ± 3.31 vs. 0.43 ± 0.28, p = 0.023). In sequential IRE procedures, the average current was 30.1 ± 5.3 A, and both the delta ampere and percentage were positive with the mean values of 5.8 ± 2.1 A and 23.8 ± 6.3%, respectively. All procedures were technically successful without any adverse events. In the follow-up, no residual unablated tumor (endpoint-1) was observed. The half-year, one-year, and two-year local tumor progression (endpoint-2) rate was 0%, 9.1%, and 27.3%. The two-year overall survival rate was 100%. Conclusions. Ethiodized oil tumor marking enables to demarcate small HCCs that were invisible on unenhanced CT. It potentially allows a safe and complete ablation in subsequent CT-guided IRE.


Kidney360 ◽  
2021 ◽  
pp. 10.34067/KID.0006972020
Author(s):  
Hirokazu Marumoto ◽  
Nobuo Tsuboi ◽  
Vivette D. D'Agati ◽  
Takaya Sasaki ◽  
Yusuke Okabayashi ◽  
...  

Background: Single nephron dynamics in progressive IgA nephropathy (IgAN) have not been studied. We applied novel methodology to explore single nephron parameters in IgAN. Methods: Non-globally sclerotic glomeruli (NSG) and globally sclerotic glomeruli (GSG) per kidney were estimated using cortical volume assessment via unenhanced computed tomography and biopsy-based stereology. Estimated single-nephron GFR (eSNGFR) and urine protein excretion (SNUPE) were calculated by dividing eGFR and UPE by the number of NSG. Associations with CKD stage and clinicopathologic findings were cross-sectionally investigated. Results: This study included 245 IgAN patients (mean age 43 y, 62% male, 45% on renin-angiotensin aldosterone system [RAAS] inhibitors pre-biopsy) evaluated at kidney biopsy. CKD stages were 10% CKD1, 43% CKD2, 19% CKD3a, 14% CKD3b and 14% CKD4-5. With advancing CKD stage, NSG decreased from mean 992,000 to 300,000 per kidney whereas GSG increased from median 64,000 to 202,000 per kidney. In multivariable models, advancing CKD stage associated with lower numbers of NSG, higher numbers of GSG, and lower numbers of GSG+NSG, indicating potential resorption of sclerosed glomeruli. In contrast to the higher mean glomerular volume and markedly elevated SNUPE in advanced CKD, the eSNGFR was largely unaffected by CKD stage. Lower SNGFR associated with Oxford scores for endocapillary hypercellularity and crescents whereas higher SNUPE associated with segmental glomerulosclerosis and tubulointerstitial scarring. Conclusions: SNUPE emerged as a sensitive biomarker of advancing IgAN. The failure of eSNGFR to increase in response to reduced number of functioning nephrons suggests limited capacity for compensatory hyperfiltration by diseased glomeruli with intrinsic lesions.


Sign in / Sign up

Export Citation Format

Share Document