signal decay
Recently Published Documents


TOTAL DOCUMENTS

108
(FIVE YEARS 22)

H-INDEX

20
(FIVE YEARS 2)

2021 ◽  
Vol 2021 (5) ◽  
Author(s):  
M. Ablikim ◽  
◽  
M. N. Achasov ◽  
P. Adlarson ◽  
S. Ahmed ◽  
...  

Abstract The decays D → K−π+π+π− and D → K−π+π0 are studied in a sample of quantum-correlated $$ D\overline{D} $$ D D ¯ pairs produced through the process e+e− → ψ(3770) → $$ D\overline{D} $$ D D ¯ , exploiting a data set collected by the BESIII experiment that corresponds to an integrated luminosity of 2.93 fb−1. Here D indicates a quantum superposition of a D0 and a $$ {\overline{D}}^0 $$ D ¯ 0 meson. By reconstructing one neutral charm meson in a signal decay, and the other in the same or a different final state, observables are measured that contain information on the coherence factors and average strong-phase differences of each of the signal modes. These parameters are critical inputs in the measurement of the angle γ of the Unitarity Triangle in B− → DK− decays at the LHCb and Belle II experiments. The coherence factors are determined to be RK3π = $$ {0.52}_{-0.10}^{+0.12} $$ 0.52 − 0.10 + 0.12 and $$ {R}_{K{\pi \pi}^0} $$ R K ππ 0 = 0.78 ± 0.04, with values for the average strong-phase differences that are $$ {\delta}_D^{K3\pi }=\left({167}_{-19}^{+31}\right){}^{\circ} $$ δ D K 3 π = 167 − 19 + 31 ° and $$ {\delta}_D^{K{\pi \pi}^0}=\left({196}_{-15}^{+14}\right){}^{\circ} $$ δ D K ππ 0 = 196 − 15 + 14 ° , where the uncertainties include both statistical and systematic contributions. The analysis is re-performed in four bins of the phase-space of the D → K−π+π+π− to yield results that will allow for a more sensitive measurement of γ with this mode, to which the BESIII inputs will contribute an uncertainty of around 6°.


Author(s):  
Julian Glandorf ◽  
Filip Klimeš ◽  
Lea Behrendt ◽  
Andreas Voskrebenzev ◽  
Till F. Kaireit ◽  
...  

2021 ◽  
Vol 14 (2) ◽  
pp. 1355-1363
Author(s):  
Felix Piel ◽  
Markus Müller ◽  
Klaus Winkler ◽  
Jenny Skytte af Sätra ◽  
Armin Wisthaler

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) is widely used in atmospheric sciences for measuring volatile organic compounds in real time. In the most widely used type of PTR-MS instruments, air is directly introduced into a chemical ionization reactor via an inlet capillary system. The reactor has a volumetric exchange time of ∼0.1 s, enabling PTR-MS analyzers to measure at a frequency of 10 Hz. The time response does, however, deteriorate if low-volatility analytes interact with surfaces in the inlet or in the instrument. Herein, we present the extended volatility range (EVR) PTR-MS instrument which mitigates this issue. In the EVR configuration, inlet capillaries are made of passivated stainless steel, and all wetted metal parts in the chemical ionization reactor are surface-passivated with a functionalized hydrogenated amorphous silicon coating. Heating the entire setup (up to 120 ∘C) further improves the time-response performance. We carried out time-response performance tests on a set of 29 analytes having saturation mass concentrations C0 in the range between 10−3 and 105 µg m−3. The 1/e-signal decay times after instant removal of the analyte from the sampling flow were between 0.2 and 90 s for gaseous analytes. We also tested the EVR PTR-MS instrument in combination with the chemical analysis of aerosols online (CHARON) particle inlet, and 1/e-signal decay times were in the range between 5 and 35 s for particulate analytes. We show on a set of example compounds that the time-response performance of the EVR PTR-MS instrument is comparable to that of the fastest flow tube chemical ionization mass spectrometers that are currently in use. The fast time response can be used for rapid (∼1 min equilibration time) switching between gas and particle measurements. The CHARON EVR PTR-MS instrument can thus be used for real-time monitoring of both gaseous and particulate organics in the atmosphere. Finally, we show that the CHARON EVR PTR-MS instrument also rapidly detects highly oxygenated species (with up to eight oxygen atoms) in particles formed by limonene ozonolysis.


2020 ◽  
Vol 7 (2) ◽  
Author(s):  
L. Viererbl ◽  
A. Kolros ◽  
M. Vinš ◽  
V. Klupák

Abstract On-line activity measurement of fission products in a primary circuit water is often used for a fuel failure detection in research and power nuclear reactors. When gamma spectrometry is used for the activity measurement, high signal from 16N radionuclide and other activation products make the detection of fission products difficult. The detection of delayed neutrons emitted from several fission products is also used; however, if the detector is placed near the outlet coolant pipe, the signal from the delayed neutrons cannot be distinguished from the neutrons emitted due to 17N decay and deuterium photofission, with exception of a reactor scram condition. In this paper, a method of discontinuing the flow of primary circuit water is described. This method is based on the water flowing through a bypass on the outlet pipe to the sampling container and the flow is periodically temporarily interrupted, e.g., using 200 s + 200 s cycles. Neutrons located in the vicinity of the sampling container are continuously detected with a measuring sampling time of less than 2 s. The signal part, corresponding to the delayed neutrons, is evaluated by the signal decay analyzing during the flow interruption. The main sources of delayed neutrons suitable for this method are 137I, 87Br, and 88Br radionuclides with half-lives of 24.5 s, 55.7 s, and 16.5 s, respectively. The method was theoretically analyzed and experimentally verified in the LVR-15 research reactor.


2020 ◽  
Author(s):  
Michael Paquette ◽  
Cornelius Eichner ◽  
Thomas R. Knösche ◽  
Alfred Anwander

AbstractThe feasibility of non-invasive axonal diameter quantification with diffusion MRI is a strongly debated topic due to the neuroscientific potential of such information and its relevance for the axonal signal transmission speed. It has been shown that under ideal conditions, the minimal diameter producing detectable signal decay is bigger than most human axons in the brain, even using the strongest currently available MRI systems. We show that resolving the simplest situations including multiple diameters is unfeasible even with diameters much bigger than the diameter limit. Additionally, the recently proposed effective diameter resulting from fitting a single value over a distribution is almost exclusively influenced by the biggest axons. We show how impractical this metric is for comparing different distributions. Overall, axon diameters currently cannot be quantified by diffusion MRI in any relevant way.


2020 ◽  
Author(s):  
Felix Piel ◽  
Markus Müller ◽  
Klaus Winkler ◽  
Jenny Skytte af Sätra ◽  
Armin Wisthaler

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) is widely used in atmospheric sciences for measuring volatile organic compounds in real time. In the most widely used type of PTR-MS instruments, air is directly introduced into a chemical ionization reactor via an inlet capillary system. The reactor has a volumetric exchange time of ~ 0.1 s enabling PTR-MS analyzers to measure at a frequency of 10 Hz. The time response does, however, deteriorate if low-volatility analytes interact with surfaces in the inlet or in the instrument. Herein, we present the “Extended Volatility Range” (EVR) PTR-MS instrument which mitigates this issue. In the EVR configuration, inlet capillaries are made of passivated stainless steel and all wetted metal parts in the chemical ionization reactor are surface-passivated with a functionalized hydrogenated amorphous silicon coating. Heating the entire set-up to 120 °C further improves the time-response performance. We carried out time-response performance tests on a set of 29 analytes having saturation mass concentrations C0 in the range between 10−3 and 105 µg m−3. 1/e-signal decay times after instant removal of the analyte from the sampling flow were between 0.2 and 90 s for gaseous analytes. We also tested the EVR PTR-MS instrument in combination with the CHARON particle inlet, and 1/e-signal decay times were in the range between 5 and 35 s for particulate analytes. We show on a set of exemplary compounds that the time-response performance of the EVR PTR-MS instrument is comparable to that of fastest flow tube chemical ionization mass spectrometers that are currently in use. The fast time response can be used for rapid (~ 1 min equilibration time) switching between gas and particle measurements. The CHARON EVR PTR-MS instrument can thus be used for real-time monitoring of both gaseous and particulate organics in the atmosphere. Finally, we show that the CHARON EVR PTR-MS instrument is capable of detecting highly oxygenated species (with up to eight oxygen atoms) in particles formed by limonene ozonolysis.


Sign in / Sign up

Export Citation Format

Share Document