pulse inversion
Recently Published Documents


TOTAL DOCUMENTS

181
(FIVE YEARS 8)

H-INDEX

30
(FIVE YEARS 2)

2020 ◽  
Vol 6 (2) ◽  
pp. 79-85
Author(s):  
Siti Masrochah ◽  
Fatimah Fatimah ◽  
Nurdianty Yunitaningrum

Background: One of MRI technique using STIR sequences, such as the cervical examination. STIR sequences used in the cervical spine due to the cervical spine is surrounded by lots of fluids and fat, to reinforce the picture of the cervical spine. According to Braun in 2003 in an article in the American College of Rheumatology, TR on STIR used is 4000 ms. Meanwhile, according to Erika J. Ulbribh in 2011 in an article in the Journal of Magnetic Resonance Imaging TR on STIR sequences were used that 4860 ms. Based on the writer's observation in several hospitals with the same flight characteristics, the value of TR on STIR sequences different - different. At one hospital using TR 5000 ms, then at other hospitals using the TR 3000 ms. TR value is used based on the theory of 2000 ms.Methods: This research is a quantitative study with an experimental approach. Data were collected from May to June 2016 in the. The subjects of this study are volunteers by using a variation of the value of Time Repetition. It is caused during data capture none of the patients with the diagnosis of the lesion or tumour. image of five variations Repetition Time value is 4090 ms, 5190 ms, 6290 ms, 7390 ms and 8490 ms. Selection of variation based on the value of TR used.Results: From the statistical test result known that There are differences in image information MRI Cervical on the variation of the Time Repetition 4090 ms, TR 5190 ms, TR 6290 ms, TR 7390 ms, and TR 8490 ms to the value of ρ value of 0.000 (ρ 0, 05).That is because Repetition Time (TR) sequences Inversion Recovery (IR) should be long enough to provide opportunities so that Net Magnetization Vectors (NMV) can be in full recovery before the next 180 RF pulse inversion. If TR is too short then each network will be recovery with different levels which will ultimately affect the weighting (weighting) is generated.Conclusion: There are differences in Cervical MRI image information on the variation of the value of 4090 ms Repetition Time, TR 5190 ms, TR 6290 ms, TR 7390 ms, and TR 8490 ms to the value of ρ value of 0.000 (ρ 0.05).


2019 ◽  
Vol 46 (8) ◽  
pp. 3475-3482 ◽  
Author(s):  
Diya Wang ◽  
Xinyu Zhang ◽  
Yuchao Sang ◽  
Zhen Qu ◽  
Qiang Su ◽  
...  

2018 ◽  
Vol 8 (11) ◽  
pp. 2219 ◽  
Author(s):  
Eui-Ji Shin ◽  
Byungwoo Kang ◽  
Jin Chang

Real-time monitoring of high-intensity focused ultrasound (HIFU) surgery is essential for safe and accurate treatment. However, ultrasound imaging is difficult to use for treatment monitoring during HIFU surgery because of the high intensity of the HIFU echoes that are received by an imaging transducer. Here, we propose a real-time HIFU treatment monitoring method based on pulse inversion of imaging ultrasound; an imaging transducer fires ultrasound twice in 0° and 180° phases for one scanline while HIFUs of the same phase are transmitted in synchronization with the ultrasound transmission for imaging. By doing so, HIFU interferences can be eliminated after subtracting the two sets of the signals received by the imaging transducer. This function was implemented in a commercial research ultrasound scanner, and its performance was evaluated using the excised bovine liver. The experimental results demonstrated that the proposed method allowed ultrasound images to clearly show the echogenicity change induced by HIFU in the excised bovine liver. Additionally, it was confirmed that the moving velocity of the organs in the abdomen due to respiration does not affect the performance of the proposed method. Based on the experimental results, we believe that the proposed method can be used for real-time HIFU surgery monitoring that is a pivotal function for maximized treatment efficacy.


Sign in / Sign up

Export Citation Format

Share Document